CA.P7.01, 04/01/08
Data subject to change without notice
Yaskawa Electric America
Page 27
Description
5-500HP
P7/Configured
NEMA 3R
P7CR
The P7/Configured package provides a P7 in a NEMA 3R enclosure, with space for several commonly used
options, such as reactors, circuit breakers, etc. The P7 and P7/Configured have been designed for flexibility
in providing the features and options commonly demanded by facility designers.
The P7 Drive is a variable torque AC drive, designed specifically for industrial applications. A new
benchmark for size, cost, performance, benefits and quality, the P7 includes numerous built-in features such
as Network Communications, PI control and energy-savings functions.
The P7 has embedded communications for Modbus. An optional interface card is also available for
DeviceNet, Profibus, EtherNet, and LonWorks.
This P7 package has a UL Type 3R rating.
Performance Features
VT Ratings: 5-150 HP, 208 VAC
5-150 HP, 230/240 VAC
5- 500 HP, 480 VAC
Overload capacity: 110% for 60 sec.
(150% peak)
Starting torque: 100% at 3 Hz
DC injection braking: at start or stop,
adjustable, current limited (anti-windmill-
ing)
Motor preheat function
Adjustable accel/decel: 0.1 to 6000 sec.
Controlled speed range: 40:1
Critical frequency rejection: 3 selectable,
adjustable bands
Torque limiting: 30-180%
Energy $aving control
Torque boost: full range, auto
Power loss ride-thru: 2 sec.
Inertia ride-thru
Auto restart after power loss or resettable
fault, selectable, programmable
Feedback signal loss detection
Serial communications loss detection
"Up/Down" floating point control capability
Stationary motor auto-tuning
Customizable monitor display
Sleep function
Run permissive input
Ramp-to-stop or coast-to-stop selection
Runtime changes in control and display
Project-specific parameter reinitialization
Service Conditions
Ambient Temperature:
-10°C to 40°C(14°F to 104°F)
Humidity: 95% RH, non-condensing
Altitude: 3300 ft; higher by derate
Input voltage: +10%/-15%
Input frequency: 50/60 Hz ± 5%
3-phase, 3-wire, phase sequence
insensitive
Protective Features
Current limited stall prevention
Heat sink over-temperature, speed
fold-back
Cooling fan operating hours recorded
Bi-directional start into rotating motor at
synchronized speed
DC bus charge indicator
Current limiting DC bus fuse
Optically-Isolated controls
Short circuit protection: Phase-phase and
phase-neutral
Ground fault protection
Electronic motor overload: UL
Current and torque limit
Fault display: last 10 faults
Fault circuit: OC, OV, OT
Over torque and under torque protection
Program security code
"Hunting" prevention logic
Reverse prohibit selectability
Configured Options
Circuit breaker
Input fuses
Input reactor
Output reactor
Engraved nameplates
Pressure/electrical transducer
Analog outputs: 2 programmable,
4-20 mA
HOA Selector Switch
Communication Interface: DeviceNet,
Profibus, EtherNet, LonWorks, Johnson
Controls METASYS N2, and Siemens
APOGEE FLN
DriveWizardTM upload/download and
monitoring/graphing software
Surge suppressor
Space heater
Keypad viewing window
50°C ambient
Leg kits (shipped loose)
Design Features
32-bit microprocessor logic
Flash upgradeable firmware
Non-volatile memory, program retention
Surface-mount devices
Displacement power factor: 0.98
Output frequency: 0.1 to 120 Hz
Frequency resolution: 0.06 Hz
Frequency regulation: 0.1%
Control Terminal Board: Quick disconnect,
removable
Carrier frequency: selectable to 15 kHz
3% DC bus reactor: 30-150 HP, 208 VAC;
30-150 HP, 240 VAC; 40-500 HP, 480 VAC;
optional on lower ratings
Keypad Operator: built-in copy feature,
6 languages
LCD display: 5 lines, 16 characters each
24 VDC control logic
Transmitter/Option power supply
Output contacts: One form C and two pro-
grammable form A
Input/output terminal status
Input terminals: 5 programmable multi-
function input terminals
Fault input: Programmable
Diagnostic fault indication in selected lan-
guage
Timer function: Elapsed time, Delay on
start, Delay on stop
RS-422/485 port: Modbus
Volts/hertz ratio: Preset and programmable
V/Hz patterns
Multi-speed settings: 5 available
Remote speed command: 0-10 VDC or
4-20 mA, direct or reverse-acting
Setpoint (PI) control with inverse or square
root input, differential control via two feed-
back capability
Feedback signal: low pass filter
Speed command: bias and gain
Analog outputs: Programmable, two,
0-10 VDC
Meter Functions: Volt, amp, kilowatt,
elapsed run time, speed command
Output Current Transformers, qty 3
UL Type 3R rating
MTBF: exceeds 28 years
Thermostatically controlled cabinet fans
Lifting eyes
Padlock hasp