CA.P7.01, 04/01/08
Data subject to change without notice
Yaskawa Electric America
Page 53
Description
5-500HP
P7/Bypass
NEMA 3R
P7BR
The P7/Bypass package in a NEMA 3R enclosure is a 3-contactor style bypass, allowing motor operation from
either the drive or across the line. This facilitates drive maintenance while the motor continues to operate. The
P7 and P7/Bypass have been designed for flexibility in providing the features and options commonly demanded
by facility designers.
The P7 Drive is a variable torque AC drive, designed specifically for industrial applications. A new benchmark
for size, cost, performance, benefits and quality, the P7 includes numerous built-in features such as Network
Communications, H/O/A, PI control and energy savings functions.
The P7 has embedded communications for Modbus. An optional interface card is also available for DeviceNet,
Profibus, EtherNet and LonWorks.
This P7 package has a UL Type 3R rating.
Performance Features
• Input, output, and bypass contactors
• Circuit breaker disconnect (MCP), with
interlocked, flange-mount operating
mechanism
• Thermal motor overload relay, class 20
• 115 VAC control transformer, fused
• Drive/Bypass selector switch
• Hand/Off/Auto selector switch
• Normal/Test selector switch
• Pilot lights, 22mm LED, for Control Power,
Drive Run, Drive Fault, Bypass Run, Motor
OL/Safety Fault and Smoke Purge
• Switch selectable auto transfer to bypass
on drive fault
• Switch selectable remote transfer to
bypass via contact closure
• Switch selectable smoke purge function
• Run mode and Fault contacts
• Control and safety circuit terminal strip
• Damper circuit safety interlock
Bypass Options
• Input reactor
• Communication Interface: DeviceNet,
Profibus, EtherNet, LonWorks, Johnson
Controls METASYS N2, and Siemens
APOGEE FLN
• Pressure/electrical transducer
• Engraved nameplates
• DriveWizard upload/download and moni-
toring/graphing software
• Analog outputs: 2 programmable, 4-20 mA
• Surge suppressor
• Space heater
• 50°C ambient
• Keypad viewing window
• Leg kits (shipped loose)
• Input fuses
Service Conditions
• Ambient Temperature:
-10°C to 40°C(14°F to 104°F)
• Humidity: 95% RH, non-condensing
• Altitude: 3300 ft; higher by derate
• Input voltage: +10%/-15%
• Input frequency: 50/60 Hz ± 5%
• 3-phase, 3-wire, phase sequence insensi-
tive
Performance Features
• VT Ratings: 5-150 HP, 208 VAC
5-150 HP, 230/240 VAC
5- 500 HP, 480 VAC
• Overload capacity: 110% for 60 sec.
(150% peak)
• Starting torque: 100% at 3 Hz
• DC injection braking: at start or stop,
adjustable, current limited (anti-windmilling)
• Motor preheat function
• Adjustable accel/decel: 0.1 to 6000 sec.
• Controlled speed range: 40:1
• Critical frequency rejection: 3 selectable,
adjustable bands
• Torque limiting: 30-180%
• Energy $aving control
• Torque boost: full range, auto
• Power loss ride-thru: 2 sec.
• Inertia ride-thru
• Auto restart after power loss or resettable
fault, selectable, programmable
• Feedback signal loss detection
• Serial communications loss detection
• "Up/Down" floating point control capability
• Stationary motor auto-tuning
• Customizable monitor display
• Sleep function
• Run permissive input
• Ramp-to-stop or coast-to-stop selection
• Runtime changes in control and display
• Project-specific parameter reinitialization
Protective Features
• Current limited stall prevention
• Heat sink over-temperature, speed fold-back
• Cooling fan operating hours recorded
• Bi-directional start into rotating motor at
synchronized speed
• DC bus charge indicator
• Current limiting DC bus fuse
• Optically-Isolated controls
• Short circuit protection: Phase-phase and
phase-neutral
• Ground fault protection
• Short circuit withstand rating: 65K RMS,
100K RMS with bus reactor
• Electronic motor overload: UL
• Current and torque limit
• Fault display: last 10 faults
• Fault circuit: OC, OV, OT
• Over torque and under torque protection
• Program security code
• "Hunting" prevention logic
• Reverse prohibit selectability
Design Features
• 32-bit microprocessor logic
• Flash upgradeable firmware
• Non-volatile memory, program retention
• Surface-mount devices
• Displacement power factor: 0.98
• Output frequency: 0.1 to 120 Hz
• Frequency resolution: 0.06 Hz
• Frequency regulation: 0.1%
• Control Terminal Board: Quick disconnect,
removable
• Carrier frequency: selectable to 15 kHz
• 3% DC bus reactor: 30-150 HP, 208 VAC;
30-150 HP, 240 VAC; 40-500 HP, 480 VAC;
optional on lower ratings
• Keypad Operator: built-in copy feature,
6 languages
• LCD display: 5 lines, 16 characters each
• 24 VDC control logic
• Transmitter/Option power supply
• Output contacts: One form C and two pro-
grammable form A
• Input/output terminal status
• Input terminals: 5 programmable multi-
function input terminals
• Fault input: Programmable
• Diagnostic fault indication in selected
language
• Timer function: Elapsed time, Delay on
start, Delay on stop
• RS-422/485 port: Modbus
• Volts/hertz ratio: Preset and programmable
V/Hz patterns
• Multi-speed settings: 5 available
• Remote speed command: 0-10 VDC or 4-
20 mA, direct or reverse-acting
• Setpoint (PI) control with inverse or square
root input, differential control via two feed-
back capability
• Feedback signal: low pass filter
• Speed command: bias and gain
• Analog outputs: Programmable, two, 0-10
VDC
• Meter Functions: Volt, amp, kilowatt,
elapsed run time, speed command
• Output Current Transformers, qty 3
• UL Type 3R rating
• MTBF: exceeds 28 years
• Thermostatically controlled cabinet fans
• Lifting eyes
• Padlock hasp