Rack-mounting 19
Rack-mounting The Server Load Balancer is 1.5U and fits in most standard 19-inch racks.
However, if you are connecting the Server Load Balancer to a ARPS Type 3
power module, a runner, shelf or tray is recommended to support the
additional weight. You will need to allow a 2U space within the rack for
each Server Load Balancer.
WARNING: The rack-mount kits alone are not sufficient to support the
weight of the Server Load Balancer when attached to an ARPS power
module. It is recommended that you use a runner, shelf or tray to support
the total weight. The rack mount kits must not be used to suspend the
Server Load Balancer from under a table or desk, or attach it to a wall.
CAUTION: You must use a full depth shelf or support that will not
obstruct the air flow through the side panels of the Server Load Balancer.
CAUTION: Disconnect all cables from the Server Load Balancer before
continuing. Remove all self adhesive pads from the underside of the
Server Load Balancer if they have been fitted.
To rack-mount your Server Load Balancer:
1 Place the unit the right way up on a hard flat surface, with the front
facing towards you.
2 Locate a mounting bracket over the mounting holes on one side of the
unit, as shown in Figure 3.
Figure 3 Fitting a bracket for rack-mounting
slb_gsg.bk Page 19 Thursday, May 31, 2001 8:57 AM