Chapter 3: mx Commands 83
[--email]
Restore the email notification service configuration to the HP Clustered File
System default settings.
[--script]
Restore the script notification service configuration to the HP Clustered File
System default settings.
If none of the options are specified, the restore operation will apply to all of
the notification services.
test—Test an event notifier service
mx eventnotifier test [--snmp] [--email] [--script]
This command verifies that events can be sent to the specified notification
service. An error will be reported if the service is disabled or is not
configured.
The options are:
[--snmp]
Test the SNMP notification service.
[--email]
Test the email notification service.
[--script]
Test the script notification service.
If none of the options are specified, all notification services will be tested.
viewconfig—View the configuration of the event notification services
mx eventnotifier viewconfig [--snmp] [--email] [--script]
The options are:
[--snmp]
Display the configuration of the SNMP notification service.
[--email]
Display the configuration of the email notification service.
[--script]
Display the configuration of the script notification service.