Updating Service Processor (SP) Firmware
G06.24 Software Installation and Upgrade Guide528593-005
7-10
Update SP Firmware Using the TSM Service
Application
9. Enter the new file location. Use the $SYSTEM.SYSnn subvolume created during
the most recent DSM/SCM Build/Apply. For example:
10. Click OK.
11. Click Yes when a message appears, warning that you have specified a
nonstandard firmware file location.
You have specified a nonstandard firmware location.
Compaq TSM will try to get the firmware information. It may take a few seconds.
Do you want to use this nonstandard firmware location?
TSM retrieves firmware information, and the firmware source file version shows the
new version in the Firmware Update dialog box. (Note that the following examples
might not match the latest firmware version.) For example:
T1089G06^02DEC02^11DEC02^ABI
VST646.vsd
$system.sys02
File name
Enter firmware file location and name:
$volume.subvolume
Specify Firmware File Location
SPCODE9
vst662.vsd
Przeglądanie stron 129