HP Integrity NonStop Release and Migration Instrukcja Użytkownika Strona 283

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 320
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 282
Updating SWAN Concentrator CLIP Firmware
G06.24 Software Installation and Upgrade Guide528593-005
C-7
If the SWAN Fast Firmware Update Fails
If the SWAN Fast Firmware Update Fails
If any CLIPs fail, you are notified in the Firmware Update Progress dialog box:
1. To review the reason for the failure, select the corresponding row. A message
similar to the following might appear:
Object Name: $ZZWAN.#SWAN1.2
Action State: Failed
Error Id: 1083
Error Description: Problem: A non-path error occurred.
Error Id: 1083.
Error Description : CLIP in STARTED state.
Recovery: None.
Object Name: $ZZWAN.#SWAN1.1
Action State: Failed
Error Id: 1083
Error Description: Problem: A non-path error occurred.
Error Id: 1083.
Error Description : CLIP in STARTED state.
Recovery: None.
2. Using the Error Id number, check online help for recovery information.
3. Reissue the Fast Firmware Update only for those CLIPs for which the firmware
update failed by selecting the Down Rev option from the FFU procedure
4. If the update fails again, before initiating the Fast Firmware Update guided
procedure again, use SCF or TSM to stop the SWAN adapter:
a. In TSM, right-click the SWAN collection in the tree pane and select Actions
from the shortcut menu. For example:
b. In the Actions dialog box, select Stop and click Perform action. The SWAN
adapter object is stopped.
vst903.vsd
Przeglądanie stron 282
1 2 ... 278 279 280 281 282 283 284 285 286 287 288 ... 319 320

Komentarze do niniejszej Instrukcji

Brak uwag