8.7.en.12 NONCRITICAL condition—I/O Module NVRAM read failure
The system is una
ble to read data from the I/O module NVR A M.
Complete the following procedure to correct this problem:
1. Record all six characters of the condition report.
2. Contact your HP authorized service representative.
8.7.en.13 NONCRITICAL condition—I/O module removed
The system detects that a n I/O module has been removed.
To correct the problem, install an I/O module.
Host conditions
The EM U has the
capability of displaying host controller dened condition reports on the EMU
alphanumeric display.
TheformatofahostconditionreportisF.F.en.ec,where:
F.F.isthehos
t element type number
en. is the t wo-character host element number
ec is the error code
Thehostcont
roller can display host controller dened error codes on the EMU alphanumeric display
Enterprise Virtual Array 3000/5000 user guide (VCS 3.110)