Hp 3000 Enterprise Virtual Array Instrukcja Użytkownika Strona 158

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 188
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 157
Tab l e 55 C ontroller Event Text Descr ip t ion File
Information Type
Description
Event Code
This hexadecimal code identies the reported event type.
Termination Code (TC)
The hexadecimal co de species the condition that generated the
termination code. It might also dene either a system or user initiated
corrective a ction.
Coupled Crash Control Codes
This single dig
it, decimal character denes the requirement for the other
controller to
initiate a coupled crash control.0. Other controller SHOULD
NOT complete a
coupled crash.1. Other controller SHOULD complete a
coupled cras
h.
Dump/Restart Control Codes This sin gle d ecimal character (0, 1, 3) denes the requirement to:0.
P erform a crash dump and then restart the controller.1. DO NOT perform
a crash dump; just restart the controller.3. DO NOT perform a crash
dump; DO NOT restart the controller
Corrective Action Codes (CAC)
These hexadecimal codes supplement the Termination Code information
to identify the faulty element and the recommended corrective action.
Software Component ID Codes
(SWCID)
These decimal codes identify software associated with the event.
Event Information Packets (EIP) These codes specify the packet organization for specictypeevents.
158
Controller fault management
Przeglądanie stron 157
1 2 ... 153 154 155 156 157 158 159 160 161 162 163 ... 187 188

Komentarze do niniejszej Instrukcji

Brak uwag