Operation 2-5
Table 2-1
Control Panel Button Functions
continued
Screen Escape Enter s Note 1 t Note 1
At Fault
Screen
N/A Clears Soft
Errors
N/A N/A
Notes:
1 There is an auto-repeat feature for the s and t buttons. When the user presses either
button for more than one-half second, the control panel behaves as if the user were
pressing and releasing the button about four times per second. This effect stops when the
user releases the button.
2 This button is sampled during power-up while all control panel LEDs are on. If it is
depressed during that time, the system updates its geometry; that is, it checks for the
presence and location of all modules and remaps all media. Use this method when
removing or installing a module permanently.
3 These buttons are sampled during power-up. If
both
are depressed during that time, the
system clears low-power memory. Use this procedure only when low-power data is
corrupted. Clearing low-power memory erases all log information, such as configuration
history, error history, and statistics. In addition, the system time, date and password
information is erased and must be re-entered.
MiniLibrary Base Module
Figure 2–3 shows the front panel of the MiniLibrary Base Module. The panel
includes a power switch and the Control Panel, which has pushbuttons, LED
indicators, and a display.
SHR-1195
U
se
C
leaner
D
r
iv
e
F
a
u
lt
L
oad
er
F
au
lt
Figure 2-3. MiniLibrary Base Module Front Panel