Hp ESL E-series Tape Libraries Instrukcja Użytkownika Strona 118

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 117
Sense
key
ASC ASCQ
Message name / description
5
81 F0
PICKER INVALID COMMAND
Picker hardware commanded to position out of system mechanical limits.
Run the Robotics to Home Position test from the O CP.
5
82 E0
ROTARY INVALID START CONDITION
Rotary hardware condition is unknown. Run the Robotics to Home
Position test from the OCP.
5
82 F0
RO TARY INVALID COMMAND
Rotary axis was commanded to a position out of its legal range. This
is an internal
code failure.
Verify that t
he host software application is supported, has up-to-date
patches, and
is correctly congured.
Verify that
the library and its components have the current rm ware .
5
83 E0
EXTENSION INVALID START CONDITION
Extension hardware condition is unknown. Run the Robotics to Home
Position test from the OCP.
5
83 F0
EXTENSION INVALID COMMAND
Extension hardware was commanded to a position out of the systems
mechanical limits.
Verify that the host soft ware application is supported, has up-to-date
patches, and is correctly congured.
Verify that the library and its components have the current rmware.
5
84
E0
VERTICAL
INVALID START CONDITION
Vertical
hardware condition is unknown. Run the Robotics to Home
Position
test from the OCP.
5
84
F0
VERTICAL INVALID COMMAND
Ver tical hardware commanded to position out of system mechanical
limits.
Run the Robotics to Home Position test from the OCP.
If the problem persists, calibrate the library.
Verify that the host soft ware application is supported, has up-to-date
patches, and is correctly congured.
Verify that the library and its components have the current rmware.
5
85 E0
HORIZONTAL INVALID START CONDITION
Horizontal hardware condition is unknown. Run the Robotics to Home
Position test from the OCP.
5
85 F0
HORIZ
ONTAL INVALID COMMAND
Horiz
ontal hardware commanded to position out of system mechanical
limi
ts.
Run t
he Robotics to Home Position test from the OCP.
If th
e problem persists, calibrate the library.
Ver
ify that the host software application is supported, has up-to-date
pat
ches, and is correctly congured.
Ver
ify that the library and its components have the current rmware.
5
87 F0
DEPTH INVALID START CONDITION
Depth hardware condition is unknown. Run the Robotics to Home
Position test from the OCP.
118