Hitachi Dynamic Link Manager Software User's Guide (for Solaris(R))3000-3-F05-50(E)

Strona 2

viGMT Greenwich Mean TimeGUI Graphical User InterfaceHBA Host Bus AdapterHDev Host DeviceHLU Host Logical UnitHTTP Hypertext Transfer ProtocolI/O Inpu

Strona 3 - Summary of amendments

3. Creating an HDLM Environment78Table 3-11: Formula for Calculating DISKTIMEOUTFor details on how to change MISSCOUNT and DISKTIMEOUT, contact the co

Strona 4

3. Creating an HDLM Environment79 Execution example:# ls -lL /dev/rdsk/c10t50060E8005271760d5s0crw-r----- 1 root sys 307, 1608 date/time /d

Strona 5 - Organization of this manual

3. Creating an HDLM Environment804. Execute the following command for the created alias device file and check that the major number, minor number, own

Strona 6 - Related Publications

3. Creating an HDLM Environment81Volume Manager ASM • ASM is bundled with Oracle RAC 11g.• ASM is used as the disk memory area for the Oracle database

Strona 7 - Conventions: Abbreviations

3. Creating an HDLM Environment82Cluster Sun Cluster 3.2 and Oracle Clusterware 11.1.0.6.0Volume Manager None (Specify an HDLM raw device)--Configurat

Strona 8

3. Creating an HDLM Environment83Volume Manager ASM • ASM is bundled with Oracle RAC 11g.• ASM is used as the disk memory area for the Oracle database

Strona 9

3. Creating an HDLM Environment84#You must apply MP3 or later.Note When a host and an Oracle RAC 11g voting disk are connected by multiple paths, HDL

Strona 10

3. Creating an HDLM Environment85Table 3-13: Formula for Calculating MISSCOUNTIn addition to the value of MISSCOUNT shown above, also change the value

Strona 11 - Conventions: Diagrams

3. Creating an HDLM Environment86In Oracle RAC 11g, for the following devices, device name should be matching between the nodes:• voting disk• Oracle

Strona 12

3. Creating an HDLM Environment87#In this example, a device file for RAC whose major number is 307 and minor number is 1608 is created.3. For the crea

Strona 13

viiConventions: DiagramsThis manual uses the following conventions in diagrams:Conventions: Fonts and symbolsFont and symbol conventions are classifie

Strona 14

3. Creating an HDLM Environment88Only domains including I/O domains that manage the HBAs connected to HDLM-managed storage are supported.• HDLM cannot

Strona 15 - Contents

3. Creating an HDLM Environment893.1.7 Memory and Disk Capacity RequirementsThis subsection explains the memory and disk capacity requirements.(1) Mem

Strona 16

3. Creating an HDLM Environment90up. 3.1.8 The Number of Paths Supported in HDLMTable 3-17: Number of LUs and Paths Supported in HDLM lists the number

Strona 17

3. Creating an HDLM Environment913.2 Flow for Creating an HDLM EnvironmentSet up the environment to use HDLM as follows.• The installation procedure i

Strona 18 - 5. Troubleshooting 343

3. Creating an HDLM Environment92Figure 3-1: Flow of HDLM Environment Setup

Strona 19 - 7. Utility Reference 435

3. Creating an HDLM Environment933.3 HDLM Installation TypesThis subsection describes the following types of HDLM installation: new installation, upgr

Strona 20 - 8. Messages 477

3. Creating an HDLM Environment943.4 Notes on Creating an HDLM EnvironmentThis section gives points to be noted when creating an HDLM environment.For

Strona 21 - Index 625

3. Creating an HDLM Environment953.4.2 Notes on Installation You cannot edit the HDLM driver configuration definition file (/kernel/drv/dlmfdrv.conf)

Strona 22

3. Creating an HDLM Environment96• The HDLM driver unconfiguration definition file (/opt/DynamicLinkManager/config/dlmfdrv.unconf)However, if both the

Strona 23 - 1. Overview of HDLM

3. Creating an HDLM Environment97Integrated trace files after re-installation: /var/opt/hitachi/HNTRLib2/spool/hntr2n.log (n indicates a file number)T

Strona 24 - 1.1 What is HDLM?

viii• General font conventions• Conventions in syntax explanationsThese conventions are described below.General font conventionsThe following table li

Strona 25 - • Virtual Storage Platform

3. Creating an HDLM Environment98• To allocate the HDLM device for each LU, execute the following command: zonecfg:zone1:device> set match=/dev/rds

Strona 26 - 1.2 HDLM Features

3. Creating an HDLM Environment99• Configuring a boot disk environment• Setting up HDLM functions• Setting up an integrated trace#• Creating a file sy

Strona 27 - 2. HDLM Functions

3. Creating an HDLM Environment100encapsulation while creating a disk group with an HDLM device or adding an HDLM device to a disk group, the KAPL0801

Strona 28 - 2.1 Devices Managed by HDLM

3. Creating an HDLM Environment1013.5 Installing HDLMWhen you install HDLM, Hitachi Network Objectplaza Trace Library (HNTRLib2) will also be installe

Strona 29 - 2.2 System Configuration

3. Creating an HDLM Environment1026. Unmount the device.If the device is mounted, unmount it. Also, if the device is set to be mounted automatically w

Strona 30

3. Creating an HDLM Environment103Figure 3-3: An example of how to edit the /etc/vfstab fileComment the shaded portions out by placing a hash mark (#)

Strona 31 - 2.3 LU Configuration

3. Creating an HDLM Environment104(4) Set Up the /kernel/drv/sd.conf FileWhen using an sd driver, depending on the HBA driver, you need to edit the /k

Strona 32

3. Creating an HDLM Environment105 To boot at the ok prompt, execute the following command:boot boot-device kernel/unix other-boot-options• To switch

Strona 33 - 2.4 Program Configuration

3. Creating an HDLM Environment106of "Error" or higher are to be output.Make sure that the /etc/syslog.conf file contains the following conf

Strona 34

3. Creating an HDLM Environment107For details, refer to the VxVM documentation.5. Remove any sd or ssd disk to be managed by HDLM from VxVM control.Fo

Strona 35

ixConventions: KB, MB, GB, and TBThis manual uses the following conventions:• 1 KB (kilobyte) is 1,024 bytes.• 1 MB (megabyte) is 1,0242 bytes.• 1 GB

Strona 36

3. Creating an HDLM Environment108• If an sd or ssd device to be managed by HDLM has been set as a Quorum device, perform the following procedures to

Strona 37 - /dev/rdsk

3. Creating an HDLM Environment109- The node is in the Offline status.- Both the current Quorum votes present and Quorum votes possible are 0.The foll

Strona 38

3. Creating an HDLM Environment1103.5.2 Preparation for Performing an Unattended Installation of HDLMAn unattended installation is an installation in

Strona 39

3. Creating an HDLM Environment111Notes• The license key file can be saved as a user-specified directory or a file name. However, this license key fil

Strona 40

3. Creating an HDLM Environment112In this example, the shaded portion shows information for each path of the device you are removing from HDLM managem

Strona 41

3. Creating an HDLM Environment113After confirming that the KAPL09211-I message has been output, execute the following command to delete the installat

Strona 42

3. Creating an HDLM Environment114# pkginfo -l DLManager PKGINST: DLManager NAME: Dynamic Link Manager CATEGORY: system ARCH: sparc

Strona 43

3. Creating an HDLM Environment115For details on how to perform this setting, see 3.5.5 Using the HDLM Device Unconfiguration Function When Performing

Strona 44 - Environment)

3. Creating an HDLM Environment116Path Health Checking : on(30)Auto Failback : on(1)Intermittent Error Monitor : offHDLM Mana

Strona 45

3. Creating an HDLM Environment117these devices.19. If you are using VxVM, execute the following command to confirm that the DEVICE column of the LUs

Strona 47

3. Creating an HDLM Environment11821. Based on the results of step 20, compare the logical device file names from before and after the HDLM 6.5.1 inst

Strona 48 - 2.8.2 Manual Path Switching

3. Creating an HDLM Environment1192. Log in to Solaris as a user with root permissions.3. Execute the format command to make sure that the sd or ssd d

Strona 49 - 2.8.3 Path Status Transition

3. Creating an HDLM Environment1206. Make sure that the key to be used for disk reservation has been registered with the device to be managed by HDLM.

Strona 50

3. Creating an HDLM Environment1210x40235c52000000020x40235c52000000010x40235c5200000003Attempting to remove all keys from the disk...Scrubbing comple

Strona 51 - Online(E) status

3. Creating an HDLM Environment122# pkgadd -d DVD-ROM-mount-point/HDLM_Solaris DLManager• If you are performing an unattended installation of HDLM, ex

Strona 52 - Failback Is Used)

3. Creating an HDLM Environment123DynamicLinkManager directory exists. If the /var/opt/DynamicLinkManager directory exists, execute the following comm

Strona 53 - Online status

3. Creating an HDLM Environment12417. Specify the devices that are to be excluded from management by HDLM, if there are any.This step is unnecessary i

Strona 54 - Offline(E)

3. Creating an HDLM Environment12520. With the reconfiguration option specified, start all nodes comprising the cluster in cluster mode, at the same t

Strona 55

3. Creating an HDLM Environment126name = view, completion time = yyyy/mm/dd hh:mm:ss#Nothing is displayed for Support Cluster even if you are using cl

Strona 56

3. Creating an HDLM Environment127Table 3-20: Information displayed by the dlmlisthdev utility for assisting HDLM transitions describes the items show

Strona 57 - Offline(C)

xiContentsPreface iIntended readers ...iOrganiza

Strona 58

3. Creating an HDLM Environment12830. Update the Sun Cluster global device namespace. Execute the following command:# /usr/cluster/bin/scgdevs 31. To

Strona 59 - 2.11 Error Management

3. Creating an HDLM Environment129these devices.To use an HDLM-managed device with a file system created by using volume management software, perform

Strona 60

3. Creating an HDLM Environment130dlmfdrv.unconf file (before editing) and Figure 3-5: Example of an /opt/DynamicLinkManager/config/dlmfdrv.unconf fil

Strona 61

3. Creating an HDLM Environment131• # reboot -- -r• boot -r (at the ok prompt)4. Execute the following command to verify that the settings were applie

Strona 62

3. Creating an HDLM Environment132• When you install HDLM while the 32-bit kernel mode is being used, only the 32-bit version of HDLM will be installe

Strona 63 - DLMgetras)

3. Creating an HDLM Environment133The following shows an example of executing the command for mounting the DVD-ROM:# mkdir /cdrom/cdrom0# mount -F hsf

Strona 64

3. Creating an HDLM Environment134hdlm_license is not already saved, a message is output asking whether a user-specified license key file has been sav

Strona 65 - Audit Log

3. Creating an HDLM Environment135Then, execute the following command at the ok prompt in all nodes:boot NoteYou must restart the host immediately aft

Strona 66 - DLMgetras utility

3. Creating an HDLM Environment136load-balancing setting was previously on. The load-balancing algorithm options are Round Robin, Extended Round Robin

Strona 67

3. Creating an HDLM Environment137A virtual disk backend is a location where virtual disk data is stored. A disk, disk slice, file, or volume (such as

Strona 68

xii2.12 Collecting Audit Log Data... 422.12.1 Categories and Audit

Strona 69 - 0None Emergency

3. Creating an HDLM Environment138To install HDLM to a host in which LDoms have been set:1. Log in to the control domain.2. Execute the ldm stop comma

Strona 70 - 2.12.4 Audit Log Data Formats

3. Creating an HDLM Environment1393. Execute the ldm unbind command to unbind the resource of the guest domain.For example, to unbind a resource of th

Strona 71 - -mm-ddThh:mm:ss.s time-zone

3. Creating an HDLM Environment140backend.8. On the control domain, execute the ldm add-vdsdev command to export the virtual disk backends from the se

Strona 72 - BasicLog

3. Creating an HDLM Environment141Figure 3-7: Configuration Example (After Installation)In this configuration example, /dev/dsk/c4t50060E8010027A82d0s

Strona 73

3. Creating an HDLM Environment1423.6 Configuring a Boot Disk EnvironmentThis section describes how to configure a boot disk environment in which HDLM

Strona 74

3. Creating an HDLM Environment143• Building a new pre-migration environment:Perform the procedure described in (4) Migration by Building a New Pre-Mi

Strona 75 - 2.14 Cluster Support

3. Creating an HDLM Environment144Figure 3-8: Flow of setting up the boot disk environment when using an existing HDLM environment as the pre-migratio

Strona 76

3. Creating an HDLM Environment1453. Set the LU slices to be used by the post-migration boot disk.4. Execute the dlmsetconf utility as follows to crea

Strona 77

3. Creating an HDLM Environment146Figure 3-9: Flow of setting up the boot disk environment when installing HDLM in the existing local boot disk enviro

Strona 78 - 3.1 HDLM System Requirements

3. Creating an HDLM Environment147• To the slices of a single LU, allocate the Solaris file system, swap device, dump device, Sun Cluster global devic

Strona 79

xiii3.8.1 Precautions ...1653.8.2 Configuring a Boot

Strona 80

3. Creating an HDLM Environment148Figure 3-10: Flow of setting up the boot disk environment when using an existing boot disk environment without HDLM

Strona 81

3. Creating an HDLM Environment149• To the slices of a single LU, allocate the Solaris file system, swap device, dump device, Sun Cluster global devic

Strona 82 - Supported by HDLM

3. Creating an HDLM Environment150Figure 3-11: Flow of setting up the boot disk environment when building a new pre-migration environment

Strona 83

3. Creating an HDLM Environment1511. Install Solaris in the pre-migration environment.2. Install Sun Cluster if required.For details, see your Sun Clu

Strona 84

3. Creating an HDLM Environment152Cluster, also initialize the Sun Cluster global device file system.The following shows an example of executing the c

Strona 85

3. Creating an HDLM Environment1537. Set the rootdev parameter for the slice containing the / (root) file system of the post-migration boot disk to th

Strona 86 - Required programs

3. Creating an HDLM Environment154...30 node1:/dev/rdsk/c8t50060E80004361D1d1 /dev/did/rdsk/d309. Edit the post-migration boot disk's /etc/vfs

Strona 87

3. Creating an HDLM Environment155- Add the slice identifier of the / (root) file system (:a value from :a to :h) to the end.An example in which Sun M

Strona 88

3. Creating an HDLM Environment156specified for the boot device.12. Boot the system from the post-migration environment.• Perform steps 13 to 17 only

Strona 89

3. Creating an HDLM Environment157The following shows an example of executing the command: # metadb -d /dev/dsk/c0t0d0s7 /dev/dsk/c0t0d1s7 /dev/dsk/c0

Strona 90 - Solaris 10)

xiv4. HDLM Operation 2674.1 Notes on Using HDLM... 2684.1.1

Strona 91

3. Creating an HDLM Environment1583.7 Migrating from a Boot Disk Environment to the Local Boot Disk EnvironmentThis section describes how to migrate f

Strona 92

3. Creating an HDLM Environment159Figure 3-12: Migration flow when coping the file system from a boot disk environment to the local boot disk environm

Strona 93

3. Creating an HDLM Environment160Perform steps 1 to 16 in the pre-migration environment.2. Allocate the LUs to be used by the boot disk in the post-m

Strona 94

3. Creating an HDLM Environment161# newfs /dev/rdsk/c0t0d0s0# newfs /dev/rdsk/c0t0d0s6# newfs /dev/rdsk/c0t0d0s3 11. Mount the Solaris file system in

Strona 95

3. Creating an HDLM Environment162/dev/dsk/c0t0d0s6 /dev/rdsk/c0t0d0s6 /usr ufs 1 no -/dev/did/dsk/d24s3 /dev/did/rdsk/d24s3 /global/.devices/

Strona 96

3. Creating an HDLM Environment163of the SDS or SVM state database to the post-migration environment. In this case, keep the pre-migration environment

Strona 97 - Required patches

3. Creating an HDLM Environment164For details on the required settings, see the documentation for the relevant application.• SDS• SVM• VxVM• Sun Stora

Strona 98

3. Creating an HDLM Environment1653.8 Configuring a Mirrored Boot Disk Environment Incorporating SVMA mirrored boot disk incorporating SVM can be mana

Strona 99

3. Creating an HDLM Environment166performing the procedures in (2) Uninstalling HDLM from the Boot Disk Environment in 3.17.3 Uninstalling HDLM.2. Upg

Strona 100 - # ls -lL HDLM-raw-device-file

3. Creating an HDLM Environment167Figure 3-13: Configuring a boot disk environment in which HDLM manages the boot disk, from the local boot disk envir

Strona 101

xv5.2 Checking Error Information in Messages...3455.3 What To Do for a Path Error ...

Strona 102

3. Creating an HDLM Environment168Figure 3-14: Mirroring a boot disk environment in which HDLM manages the boot diskIn this example, the LU device nam

Strona 103

3. Creating an HDLM Environment169# metadb -a c8t50060E08000436D1d5s7 3. Decide the metadevice names.In this procedure, specify the settings as follow

Strona 104

3. Creating an HDLM Environment170 7. Execute the metaroot command. # metaroot d10 8. Reboot the host.9. When the host starts, check the swap device a

Strona 105

3. Creating an HDLM Environment171d10: Mirror Submirror 0: d11 State: Okay Submirror 1: d12 State: Okay Pass: 1 Read option: rou

Strona 106 - DISKTIMEOUT

3. Creating an HDLM Environment172131717 0 - c8t50060E08000436D1d4000003 0001.0000.0000000000653600.0006 HITACHI .DF600F .7701015

Strona 107

3. Creating an HDLM Environment173Figure 3-15: Current boot disks and boot disks after the migrationThe LU device names of the current boot disks are

Strona 108

3. Creating an HDLM Environment174Table 3-22: Metadevice names2. Create metadevices on the HDLM device, and then mirror them (single mirror). # metain

Strona 109

3. Creating an HDLM Environment175 # newfs /dev/md/rdsk/d100# newfs /dev/md/rdsk/d300 5. Mount the Solaris basic file system of the post-migration env

Strona 110

3. Creating an HDLM Environment1769. Execute the metaroot command, using the -R option to specify the mount point of the / (root) file system after th

Strona 111 - /var/tmp during installation

3. Creating an HDLM Environment177Figure 3-16: Booting from the post-migration environment12. When the host starts, confirm that the swap device and d

Strona 112 - Number of LUs 1 to 256

 Relevant program products Hitachi Dynamic Link Manager version 6.5.1For details about applicable OSs, see the Release Notes. TrademarksAIX

Strona 113

xvi7.2 The DLMgetras Utility for Collecting HDLM Error Information... 4387.2.1 Format...

Strona 114

3. Creating an HDLM Environment178largefiles/logging/xattr/onerror=panic/dev=1540064 on Mon Mar 9 11:00:25 2009/usr on /dev/md/dsk/d300 read/write/se

Strona 115 - 3.3 HDLM Installation Types

3. Creating an HDLM Environment179 d101: Submirror of d100 State: Okay Size: 25190400 blocks (12 GB) Stripe 0: Device

Strona 116 - /etc/vx/

3. Creating an HDLM Environment180.77010152 0043 1C Online Non 35 0 - c8t50060E08000436D1d7000006 00

Strona 117 - 3.4.2 Notes on Installation

3. Creating an HDLM Environment181Figure 3-17: Current boot disks and boot disks after the migrationThe LU device names of the current boot disks are

Strona 118

3. Creating an HDLM Environment182Table 3-23: Metadevice names2. Create metadevices on the sd/ssd device, and then mirror them. (Single mirror) # meta

Strona 119

3. Creating an HDLM Environment183 # newfs /dev/md/rdsk/d10# newfs /dev/md/rdsk/d30 5. Mount the Solaris basic file system of the post-migration envir

Strona 120

3. Creating an HDLM Environment1849. Execute the metaroot command.Use the -R option to specify the mount point of the / (root) file system after the m

Strona 121

3. Creating an HDLM Environment185 # swap -lswapfile dev swaplo blocks free/dev/md/dsk/d20 85,20 16 8409584 8409584 # dumpadm

Strona 122 - 3.4.5 Notes on the Disk Label

3. Creating an HDLM Environment18615. Execute the metastat command to confirm that the two-mirror configuration has been correctly configured. # metas

Strona 123 - 3.5 Installing HDLM

3. Creating an HDLM Environment1873.9 Checking the Path ConfigurationHDLM functions, such as load balancing and failover, are only available for HDLM

Strona 124 - /etc/vfstab file is shown in

xvii8.10 KAPL10001 to KAPL11000 ...5608.11 KAPL11001 to KAPL12000 ...

Strona 125 - #) at the

3. Creating an HDLM Environment188making sure that an HDLM device corresponding to the sd or ssd device has been created.

Strona 126

3. Creating an HDLM Environment1893.10 Setting Up HDLM FunctionsHDLM includes functions like the load balancing function, the automatic failback funct

Strona 127

3. Creating an HDLM Environment190Table 3-24: The default and recommended values for each function(1) Setting Up Load BalancingYou can select whether

Strona 128

3. Creating an HDLM Environment191• exrr for the Extended Round Robin algorithm•lio for the Least I/Os algorithm•exlio for the Extended Least I/Os alg

Strona 129

3. Creating an HDLM Environment192If you set the number of times that the error needs to occur to 1, the above condition does not need to be satisfied

Strona 130

3. Creating an HDLM Environment193error in the -intvl parameter, and the number of times that the error needs to occur in the -iemnum parameter. When

Strona 131

3. Creating an HDLM Environment194Table 3-26: Values for the trace level settingIf an error occurs, you might have to set the trace level to 1 or high

Strona 132 - Not Being Used)

3. Creating an HDLM Environment195(8) Setting the Number of Error Log FilesThe number of the error log files (the HDLM manager log (dlmmgrn.log (n ind

Strona 133

3. Creating an HDLM Environment196to 1024000 kilobytes of trace data.The following shows an example command that is used to set the number of trace fi

Strona 134

3. Creating an HDLM Environment197This example shows how to enable the collection of audit log data: # /opt/DynamicLinkManager/bin/dlnkmgr set -audlog

Strona 136

3. Creating an HDLM Environment198 # /opt/DynamicLinkManager/bin/dlnkmgr set -audfac local0 3.10.3 Checking the Updated SettingsThis chapter describes

Strona 137

3. Creating an HDLM Environment1993.11 Setting up Integrated TracesWhen HDLM is used, the dlnkmgr command logs are output to the integrated trace info

Strona 138

3. Creating an HDLM Environment200If HNTRLib2 has already been installed on a host when you install HDLM, the settings in the trace library will be i

Strona 139 - Item Description

3. Creating an HDLM Environment201press the Enter key.A screen to set the size of the integrated trace file appears. The current value is displayed in

Strona 140 - Being Used)

3. Creating an HDLM Environment202The default value is 4. You can specify a value from 1 to 16. The value set here becomes the maximum of n in /var/op

Strona 141

3. Creating an HDLM Environment203A screen to set the monitoring interval appears. The current value is displayed in Current Span(sec).5. Enter a shor

Strona 142

3. Creating an HDLM Environment204value is 0.If you do not want to change the monitoring interval, leave New Span(sec) blank, type !, and then press t

Strona 143

3. Creating an HDLM Environment205The new setting is applied and the Hitachi Network Objectplaza Trace Library setup menu appears again.3.11.7 Finishi

Strona 144

3. Creating an HDLM Environment206# rm /opt/hitachi/HNTRLib2/mmap/hntr2mmap.mm 6. Execute the following command to start the integrated trace collecti

Strona 145

3. Creating an HDLM Environment2073.12 Creating File Systems for HDLM (When Volume Management Software Is Not Used)When volume management software is

Strona 146

1Chapter1. Overview of HDLMHDLM is a software package that manages paths between a host and a storage system. HDLM is designed to distribute loads acr

Strona 147

3. Creating an HDLM Environment208Figure 3-19: An output example for the mount -p commandEdit the /etc/vfstab file as appropriate based on the setting

Strona 148

3. Creating an HDLM Environment2093.13 Setting Up VxVMWhen you are using VxVM, VxVM accesses an LU by using an HDLM device.VxVM will automatically rec

Strona 149

3. Creating an HDLM Environment210The following describes the procedure for checking whether the shaded HDLM devices are recognized.•vxdisk commandMak

Strona 150

3. Creating an HDLM Environment211in the format cUtXdYsZ, corresponding to the device name of the enclosure.NoteThe device name of the enclosure corre

Strona 151

3. Creating an HDLM Environment212be removed from VxVM management. To remove non- HDLM devices from VxVM management, see (2) Removing Devices from VxV

Strona 152

3. Creating an HDLM Environment2133.13.3 Removing Devices from VxVMVxVM uses HDLM devices to access LUs managed by HDLM. Therefore, you must remove no

Strona 153

3. Creating an HDLM Environment214Figure 3-21: Devices That Are Recognized by VxVM before They Are Removed from VxVMYou must remove the following non-

Strona 154

3. Creating an HDLM Environment215actually created.Only one HDLM device is created for one LU#. However, for one LU, VxVM recognizes the same number o

Strona 155

3. Creating an HDLM Environment216The settings files necessary for device suppression are created by selecting menu task 17 (Prevent multipathing/Supp

Strona 156

3. Creating an HDLM Environment217Figure 3-23: When HBA ports on the alternate path differ from those on the primary path connected to the Hitachi sto

Strona 157

1. Overview of HDLM21.1 What is HDLM?With the widespread use of data warehousing and increasing use of multimedia data, the need for high-speed proces

Strona 158

3. Creating an HDLM Environment218execution result of the dlmvxexclude utility.For details on the dlmvxexclude utility, see 7.7 The dlmvxexclude Utili

Strona 159

3. Creating an HDLM Environment219Figure 3-24: Example of a description in the /etc/vx/vxvm.exclude (controllers section)The shaded portion indicates

Strona 160 - # ldm stop ldg2

3. Creating an HDLM Environment220The devices displayed for HDevName (the shaded portion) are the HDLM devices that must be recognized by VxVM. In the

Strona 161

3. Creating an HDLM Environment221VxVM of 3.13.3 Removing Devices from VxVM.6. Execute the vxdmpadm command on the HDLM devices listed by the vxdisk c

Strona 162

3. Creating an HDLM Environment222(3) Removing Devices From VxVM on a Path BasisIf all the physical paths to one LU go through the same HBA, devices a

Strona 163 - are HDLM devices

3. Creating an HDLM Environment223Figure 3-25: When the HBA Port of the Physical Path Connected to a Hitachi Storage System Is the Same As the One Con

Strona 164

3. Creating an HDLM Environment224numbers and devices.The devices to be removed from VxVM are output to the paths section in the execution result of t

Strona 165 - /usr file system

3. Creating an HDLM Environment225Figure 3-26: Example of a description in the /etc/vx/vxvm.exclude (paths section)The shaded portion indicates the sp

Strona 166

3. Creating an HDLM Environment226that must be recognized by VxVM. In the above example, it is c4t0d0.5. Execute the vxdisk command to list devices th

Strona 167

3. Creating an HDLM Environment2277. If you have set up vxvm.exclude again, execute the following command to restart the host and apply the setting. #

Strona 168

1. Overview of HDLM3• Lightning 9900V Series• Thunder 9500V Series• Universal Storage Platform V/VM• Virtual Storage Platform

Strona 169

3. Creating an HDLM Environment228Example 1:The vxdisk command does not display HDLM devices but displays the sd or ssd devices corresponding to those

Strona 170

3. Creating an HDLM Environment229The vxdmpadm command displays c3t0d0 and c4t1d0 in addition to the HDLM device c5t0d0, and the STATE column shows EN

Strona 171

3. Creating an HDLM Environment230• Devices in /etc/vx/vxvm.exclude that do not include dlmndrv@4. For devices whose tXdY portions are the same, chang

Strona 172

3. Creating an HDLM Environment231Figure 3-28: The /etc/vx/vxvm.exclude file (after editing)Among the non-HDLM devices in the ENABLED state, there mig

Strona 173 - / (root) file system)

3. Creating an HDLM Environment232If there is more than one candidate for the controller number to be assigned in step 4, you might not be able to rem

Strona 174

3. Creating an HDLM Environment233group to be registered in Sun Cluster into only one of the nodes.5. If the VxVM disk group is not registered in Sun

Strona 175

3. Creating an HDLM Environment234NoteAfter registering the VxVM disk group into a Sun Cluster disk device group, do not use the VxVM command to impor

Strona 176

3. Creating an HDLM Environment2353.14 Setting Up SDSIf SDS is installed on an HDLM host, SDS uses the logical device file name of the HDLM device to

Strona 177

3. Creating an HDLM Environment236orboot -r (at the ok prompt)For more information on SDS settings, refer to the SDS documentation.3.14.2 Registering

Strona 178

3. Creating an HDLM Environment237metadevices created on a shared diskset. When using Sun Cluster, you use the device ID in the device name of the dis

Strona 179

1. Overview of HDLM41.2 HDLM FeaturesHDLM features include the following:The ability to distribute a load across multiple paths. This is also known as

Strona 180 - Environment

3. Creating an HDLM Environment238When using Sun Cluster (stripe type):host1# metainit -s diskset1 d1 1 2 /dev/did/dsk/d10s0 /dev/did/dsk/d11s0 5. Cre

Strona 181

3. Creating an HDLM Environment2393.15 Setting Up SVMIf SVM is installed on an HDLM host, SVM uses the logical device file name of the HDLM device to

Strona 182

3. Creating an HDLM Environment240orboot -r (at the ok prompt)For more information on SVM settings, refer to the SVM documentation.3.15.2 Registering

Strona 183

3. Creating an HDLM Environment241created on a shared diskset. When using Sun Cluster, you use the device ID in the device name of the disk.NoteWhen y

Strona 184

3. Creating an HDLM Environment242When using Sun Cluster (stripe type):host1# metainit -s diskset1 d1 1 2 /dev/did/dsk/d10s0 /dev/did/dsk/d11s0 5. Cre

Strona 185

3. Creating an HDLM Environment2433.16 Setting Up VCSWhen VCS is installed on an HDLM host, you can register HDLM devices, or VxVM disk groups contain

Strona 186

3. Creating an HDLM Environment244If the number of paths differs depending on an HDLM device, use the maximum number for the calculation.#2The I/O tim

Strona 187 - 3.8.1 Precautions

3. Creating an HDLM Environment2453.17 Uninstalling HDLMThis section explains how to return the HDLM environment to the way it was before HDLM was ins

Strona 188

3. Creating an HDLM Environment246storage system. This information will enable you to keep the correspondence with the logical device file names after

Strona 189

3. Creating an HDLM Environment2477. If HDLM devices are being used in Solaris 10 ZFS, execute the following command to export all ZFS storage pools t

Strona 190

5Chapter2. HDLM FunctionsThis chapter describes the various functions that are built into HDLM. Before the function specifications are explained thoug

Strona 191

3. Creating an HDLM Environment248As the utility instructs, enter the name of the VxVM disk device group you want to unregister.If the HDLM device has

Strona 192

3. Creating an HDLM Environment249 8. Confirm that the cluster node enters the maintenance mode.Make sure that the node that is in the maintenance mod

Strona 193

3. Creating an HDLM Environment250(3) Remove VCS SettingsIf you are using VCS, before uninstalling HDLM, unregister the HDLM devices and VxVM disk gro

Strona 194

3. Creating an HDLM Environment251# vxdg deport disk-group-name 3. To enable VxVM management, delete the entries for sd or ssd devices and the entries

Strona 195

3. Creating an HDLM Environment252When using Sun Cluster:host1# umount /global/diskset1/d1host1# metaclear -s diskset1 d1 2. Delete the disk from the

Strona 196

3. Creating an HDLM Environment253 When using a shared diskset1. Delete the shared volume.The following shows an example of executing the command.When

Strona 197

3. Creating an HDLM Environment254NoteWhen uninstalling HDLM on a host where a Device Manager Agent 5.0 or later is installed, do not execute any of t

Strona 198

3. Creating an HDLM Environment255Execute one of the following commands:•# reboot -- -r• boot -r (at the ok prompt)When Sun Cluster is being used:Exec

Strona 199

3. Creating an HDLM Environment256Figure 3-30: Configuration Example (Before Uninstallation)#A virtual disk backend is a location where virtual disk d

Strona 200

3. Creating an HDLM Environment257The following figure shows a configuration example for an LDoms environment before uninstalling HDLM.ldg1 An I/O dom

Strona 201

2. HDLM Functions62.1 Devices Managed by HDLMBelow is a list of devices that can or cannot be managed by HDLM. The devices that can be managed by HDLM

Strona 202 - 3.8.4 Uninstalling HDLM

3. Creating an HDLM Environment258To uninstall HDLM from a host in which LDoms have been set:1. Log in to the control domain.2. Execute the ldm stop c

Strona 203

3. Creating an HDLM Environment259For example, to unbind a resource of the guest domain ldg2, execute the command as follows:# ldm unbind ldg24. Execu

Strona 204 - (root) d100 d101

3. Creating an HDLM Environment260virtual disk backends from the service domain on the I/O domain to which HDLM will be installed.For example, to expo

Strona 205

3. Creating an HDLM Environment261Figure 3-31: Configuration Example (After Uninstallation)In this configuration example, /dev/dsk/c2t50060E8010027A82

Strona 206

3. Creating an HDLM Environment262later:1. Execute the following command to import the disk group: # vxdg import disk-group-name 2. To use a volume th

Strona 207

3. Creating an HDLM Environment2635. Set up a Quorum device at any of the nodes that constitute the cluster.Check the device ID of the sd or ssd devic

Strona 208 - 16. Uninstall HDLM

3. Creating an HDLM Environment2643.17.5 Uninstalling Hitachi Network Objectplaza Trace Library (HNTRLib2)When you uninstall HDLM, if the KAPL09019-E

Strona 209

3. Creating an HDLM Environment265files will not be deleted during uninstallation. In this case delete these files after uninstallation.3.17.6 Uninsta

Strona 210

3. Creating an HDLM Environment266• Even if you attempt to uninstall HNTRLib2 when HNTRLib is installed, HNTRLib will not be uninstalled. If no other

Strona 211

267Chapter4. HDLM OperationThis chapter describes operating procedures for HDLM, including how to operate HDLM and the HDLM manager, and how to change

Strona 212

2. HDLM Functions72.2 System ConfigurationHDLM manages routes between a host and a storage system by using the SCSI driver (sd or ssd driver). The hos

Strona 213

4. HDLM Operation2684.1 Notes on Using HDLMThis section explains the notes on using HDLM and using the environment in which HDLM is installed. Make su

Strona 214

4. HDLM Operation269The shaded portion indicates mapping from combinations of sd or ssd device types and instance numbers to HDLM device logical devic

Strona 215

4. HDLM Operation2704.1.7 Starting the Host, System, and HDLM in a Solaris 10 EnvironmentWhen starting the hostIf the host is started in single-user m

Strona 216

4. HDLM Operation2712. Execute the following HDLM command to place the paths online: # /opt/DynamicLinkManager/bin/dlnkmgr online -s Even if the paths

Strona 217

4. HDLM Operation272• Changing the configuration of the HDLM operating environment• Applying an HDLM service pack#In single-user mode, HDLM command ac

Strona 218

4. HDLM Operation2734.2 HDLM Operations Using CommandsThis section explains how to use the HDLM command operations to utilize HDLM functions. For deta

Strona 219

4. HDLM Operation2744.2.3 Changing the Status of PathsThis section explains how to change path statuses.(1) Changing the Status of Paths to OnlineTo c

Strona 220

4. HDLM Operation275(2) Changing the Status of Paths to Offline(C)To change the status of paths to Offline(C):1. Check the current status of the paths

Strona 221

4. HDLM Operation276 4.2.4 Viewing LU InformationThis section explains how to display LU information by using the dlnkmgr command.To display LU inform

Strona 222 - 1 and then

4. HDLM Operation277Information). The execution result of this operation is displayed on a single line for each path.The following shows an example of

Strona 223 - 2 and then

Summary of amendmentsThe following table lists changes in this manual (3000-3-F05-50(E)) and product changes related to this manual.In addition to the

Strona 224

2. HDLM Functions8Figure 2-1: HDLM System ConfigurationTable 2-1: HDLM System Components lists the HDLM system components.Table 2-1: HDLM System Compo

Strona 225 - Monitoring Interval

4. HDLM Operation278# /opt/DynamicLinkManager/bin/dlnkmgr clear -pdstKAPL01049-I Would you like to execute the operation? Operation name = clear [y/n]

Strona 226 - 7, and then

4. HDLM Operation279 # /opt/DynamicLinkManager/bin/dlnkmgr view -sys -audlogAudit Log : offAudit Log Category : -Audi

Strona 227 - Settings

4. HDLM Operation280KAPL01001-I The HDLM command completed normally. Operation name = set, completion time = yyyy/mm/dd hh:mm:ss# To check whether th

Strona 228

4. HDLM Operation281the -sys -lic parameter to make sure that the license is installed correctly.The following shows an example of executing the comma

Strona 229 - Software Is Not Used)

4. HDLM Operation2824.2.11 Viewing HDLM Component InformationThis section explains how to display HDLM component information.To display HDLM component

Strona 230 - /etc/vfstab file to set

4. HDLM Operation2834.3 Starting and Stopping the HDLM ManagerIf an error occurs in the system, such as in an HDLM program, you may need to manually s

Strona 231 - 3.13.1 Creating a Disk Group

4. HDLM Operation284 # /opt/DynamicLinkManager/bin/dlnkmgr view -sys -msrvHDLM Manager Ver WakeupTimeDeadKAPL01001-I The HDLM command completed n

Strona 232

4. HDLM Operation2854.4 HDLM Resident ProcessesTable 4-1: HDLM resident processes lists and describes the resident processes in HDLM. To monitor these

Strona 233

4. HDLM Operation2864.5 Changing the Configuration of the HDLM Operating EnvironmentThis section describes how to reconfigure the environment for runn

Strona 234 - 3.13.2 Creating VxVM Volumes

4. HDLM Operation287dlmfdrv.conf).3. Execute the dlmsetconf utility for creating the HDLM driver configuration definition file.Edit the HDLM driver un

Strona 235

2. HDLM Functions92.3 LU ConfigurationAfter you have properly installed HDLM, the LU configuration will change as follows:Before the installation of H

Strona 236

4. HDLM Operation288When using VxVM, execute the following command to confirm that the DEVICE column of the LUs being managed by HDLM is displayed in

Strona 237

4. HDLM Operation289Execute the following command to display the driver configuration information, and then refer to the instance field of the HDLM dr

Strona 238

4. HDLM Operation290Environment.2. Change the path configuration.3. Return to the HDLM boot disk environment, following the procedure described in 3.6

Strona 239

4. HDLM Operation291• Reconfiguring an LU that is not managed by HDLM, as an HDLM-managed deviceReconfigure an LU that has already been added to the h

Strona 240

4. HDLM Operation292replaced, processing to unconfigure or reconfigure the HBA driver and either the sd or ssd driver might not complete until the hos

Strona 241 - # reboot

4. HDLM Operation293• If the major and minor numbers of the sd or ssd device of an LU to be newly added to HDLM matches the major or minor number of a

Strona 242

4. HDLM Operation294Figure 4-1: Example of executing the format command3. Execute the dlmsetconf utility for creating the HDLM driver configuration de

Strona 243 - DISABLED

4. HDLM Operation295Specify settings as shown in (2) Removing Devices from VxVM on a Controller Basis or (3) Removing Devices From VxVM on a Path Basi

Strona 244

4. HDLM Operation2968. Register the added LU to the application.(3) Adding a New LU By Restarting the Nodes (When Using Sun Cluster)NoteHave the HDLM

Strona 245

4. HDLM Operation2971. Set up the storage system and switch so that Solaris recognizes the LU.2. Check the LU newly recognized by the node.You can che

Strona 246

2. HDLM Functions10Figure 2-2: LU Configuration Recognized by the Host After the Installation of HDLMTable 2-2: Components Recognized by the Host list

Strona 247

4. HDLM Operation298Execute the following command on any node: # /usr/cluster/lib/sc/scsi -c inkeys -d the-name-of-the-logical-device-file-on-slice-2-

Strona 248

4. HDLM Operation2999. Make sure that the logical device files for the sd or ssd device are backed up.When you restart the node, with the reconfigurat

Strona 249

4. HDLM Operation300Devices from VxVM.12. Stop all nodes in the cluster.If the key is displayed in step 4, and nodes are running in non-cluster mode i

Strona 250 - ENABLED

4. HDLM Operation301Trace File Size(KB) : 1000Number Of Trace Files : 4Path Health Checking : on(30)Auto Failback

Strona 251

4. HDLM Operation30217. Delete the device ID information for devices that do not exist.Execute the following command: # /usr/cluster/bin/scdidadm -C 1

Strona 252

4. HDLM Operation303 # /usr/cluster/bin/scdidadm -r 19. Notify the node of the most recent device ID information.Execute the following command: # /usr

Strona 253

4. HDLM Operation304results of the command, compare the correspondence with the correspondence that took place before the HDLM installation, and then

Strona 254

4. HDLM Operation305Figure 4-3: Example of executing the format command3. If setup is performed for Quorum devices and disk device groups, on an LU ne

Strona 255

4. HDLM Operation306The following shows an example of executing the command: # /usr/cluster/lib/sc/scsi -c inkeys -d /dev/rdsk/c3t50060E80033A9902d2s2

Strona 256

4. HDLM Operation3077. If you do not want HDLM to manage one of the LUs newly recognized by the node, set up the LU so that it is excluded from HDLM m

Strona 257 - 3.14.1 Notes

2. HDLM Functions112.4 Program ConfigurationHDLM is actually a combination of several programs. Because each program corresponds to a specific HDLM op

Strona 258

4. HDLM Operation308indicates the path accessing the LU recognized for the first time by the HDLM driver.11. Delete the device ID information for devi

Strona 259

4. HDLM Operation30912. Allocate the device ID.Execute the following command: # /usr/cluster/bin/scdidadm -r 13. Notify the node of the most recent de

Strona 260

4. HDLM Operation310Check the correspondence between HDevName (the name of the logical device file of the HDLM device) and iLU (the internal LU number

Strona 261 - 3.15.1 Notes

4. HDLM Operation311(1) Changing the Configuration by Restarting the Host1. Back up the data in the file systems, volumes, and metadevices that use th

Strona 262

4. HDLM Operation312LU you are deleting, replace the LU.9. Shut down the host.10. Change the configuration.11. Boot the host.12. Make sure that Solari

Strona 263

4. HDLM Operation313 The KAPL10242-I message appears when you execute the dlmsetconf utility. Type y in response.15. Execute the following command to

Strona 264

4. HDLM Operation314> ### Path=/pci@8,700000/SUNW,emlxs@1/fp@0,0/ssd@w50060e80033a9938,2> ### Device=ssd84 target=134012 lun=2> ### Path=/pci

Strona 265 - 3.16 Setting Up VCS

4. HDLM Operation315In the lines that define the LU that is to be removed from HDLM management, delete the hash mark (#) in front of the LDEV property

Strona 266

4. HDLM Operation316# /usr/cluster/bin/scgdevs 25. If you cleared the settings for a Quorum device in step 3, perform the following procedure:When usi

Strona 267 - 3.17 Uninstalling HDLM

4. HDLM Operation317in step 1.31. If you released file system settings in steps 2 to 4, check the HDLM devices after reconfiguration, and then set up

Strona 268

2. HDLM Functions12Table 2-3: Function of HDLM ProgramsProgram name FunctionsHDLM command Provides the dlnkmgr command, which enables you to:• Manage

Strona 269

4. HDLM Operation318 # /opt/DynamicLinkManager/bin/dlmcfgmgr -a The HDLM device will be deleted without restarting the host.5. Execute the dlnkmgr com

Strona 270

4. HDLM Operation3194.5.5 Specifying Whether a Logical Unit Is To Be Managed by HDLM (When Not Using Sun Cluster)This section describes the procedures

Strona 271

4. HDLM Operation320 # /opt/DynamicLinkManager/bin/dlmsetconf -u 4. Restart the host, with the reconfiguration option specified: # reboot -- -r(2) Cha

Strona 272

4. HDLM Operation321Using a text editor, edit the definitions in the HDLM driver unconfiguration definition file (/opt/DynamicLinkManager/config/dlmfd

Strona 273

4. HDLM Operation322definition file (/kernel/drv/dlmfdrv.conf).Execute following the dlmsetconf utility to apply the settings in the HDLM driver uncon

Strona 274

4. HDLM Operation323The shaded portion indicates the LDEV information about the LU that is to be removed from HDLM management.3. If setup is being per

Strona 275 - 3.17.3 Uninstalling HDLM

4. HDLM Operation324Figure 4-8: The /opt/DynamicLinkManager/config/dlmfdrv.unconf file (before editing)Figure 4-9: The /opt/DynamicLinkManager/config/

Strona 276

4. HDLM Operation325Figure 4-10: Result output by executing the dlmvxexclude utilityFigure 4-11: Coding in the /etc/vx/vxvm.exclude fileThe shaded por

Strona 277

4. HDLM Operation326For details on the dlmvxexclude utility, see 7.7 The dlmvxexclude Utility for Assisting Creation of the VxVM Configuration File.7.

Strona 278

4. HDLM Operation327HDLM Alert Driver Ver WakeupTime ElogMem SizeAlive x.x.x-xx yyyy/mm/dd hh:mm:ss 4096HDLM Driver Ver

Strona 279

2. HDLM Functions132.5 Position of the HDLM Driver and HDLM DeviceThe HDLM driver is positioned above the SCSI driver. Each application on the host us

Strona 280

4. HDLM Operation328Execute the following command: # /usr/cluster/bin/scdidadm -C 13. Allocate the device ID.Execute the following command: # /usr/clu

Strona 281

4. HDLM Operation329Execute the following command to clear the install mode of a cluster when it consists of two nodes:# /usr/cluster/bin/scconf -c -q

Strona 282

4. HDLM Operation3303. If setup is being performed for Quorum devices and disk device groups in the LU to be managed by HDLM, release the LU settings.

Strona 283

4. HDLM Operation331The following shows an example of executing the command: # /usr/cluster/lib/sc/scsi -c scrub -d /dev/rdsk/c3t50060E80033A9902d2s2

Strona 284

4. HDLM Operation332Figure 4-15: The /opt/DynamicLinkManager/config/dlmfdrv.unconf file (after editing)The shaded portion indicates the text to be edi

Strona 285

4. HDLM Operation333NoteThe following message might be output to the console window or syslog while the node is running: Could not read symbolic link

Strona 286 - (HNTRLib2)

4. HDLM Operation334• Even when cluster software is used, it is not displayed in Support Cluster. Nevertheless, no problem exists with the functionali

Strona 287 - (HNTRLib)

4. HDLM Operation335Execute the following command: # /usr/cluster/bin/scdidadm -r 19. Notify the node of the most recent device ID information.Execute

Strona 288

4. HDLM Operation336that took place before the HDLM installation, and then re-register HDLM devices with the programs that will use them.If you want t

Strona 289 - 4. HDLM Operation

4. HDLM Operation337Figure 4-16: Example of executing the format command3. If setup is performed for Quorum devices and disk device groups in the LU t

Strona 290 - 4.1.3 iostat Command

2. HDLM Functions142.6 Logical Device Files for HDLM DevicesWhen you install HDLM, a logical device file to be used by HDLM will be created for each L

Strona 291 - 4.1.6 Using a Sun HBA

4. HDLM Operation338If the key is displayed, place the LU under HDLM management by following the steps from step 5 of (2) Changing a Non-HDLM-Managed

Strona 292 - 4.1.8 Upgrading Solaris

4. HDLM Operation339Figure 4-18: The /opt/DynamicLinkManager/config/dlmfdrv.unconf file (after editing)The shaded portion indicates the text to be edi

Strona 293

4. HDLM Operation3409. Delete the device ID information for devices that do not exist.Execute the following command: # /usr/cluster/bin/scdidadm -C 10

Strona 294 - Boot Disk Environment

4. HDLM Operation341Execute the following command: # /usr/cluster/bin/scgdevs 13. When using an HDLM-managed device, as a Quorum device, set the Quoru

Strona 295 - 4.2.1 Notes on Using Commands

4. HDLM Operation34216. Create the file system and set up the global mount as necessary.For details, refer to the Sun Cluster documentation.

Strona 296

343Chapter5. TroubleshootingThis chapter describes how to properly use HDLM error information, and then how to resolve the problem, if an error occurs

Strona 297

5. Troubleshooting3445.1 Information collected by using the DLMgetras utility for collecting HDLM error informationImmediately after an error occurs,

Strona 298 - 4.2.4 Viewing LU Information

5. Troubleshooting3455.2 Checking Error Information in MessagesWhen you want to configure the system so that HDLM messages are output to syslog, speci

Strona 299

5. Troubleshooting346• Host port number (hexadecimal)• Bus number (hexadecimal)• Target ID (hexadecimal)• Host LU number (hexadecimal)The path name is

Strona 300

5. Troubleshooting3475.3 What To Do for a Path ErrorWhen a path error is detected, HDLM performs a failover on the path and outputs the KAPL08022-E me

Strona 301

2. HDLM Functions15Block logical device files for HDLM devices are created in /dev/dsk. Character logical device files for HDLM devices are created in

Strona 302 - 4.2.9 Updating the License

5. Troubleshooting348Figure 5-2: Troubleshooting Procedure When a Path Error OccursIf an error occurs in a boot disk environment on a path connected t

Strona 303

5. Troubleshooting349environment.5.3.3 Identifying the Error PathCheck the obtained path information to find the path with the error. In the Status co

Strona 304

5. Troubleshooting3505.4 Actions to Take for a Path Error in a Boot Disk EnvironmentThis section describes the action to take if an error occurs in a

Strona 305

5. Troubleshooting351If an error occurs on one or more of the paths to the boot diskHDLM outputs the KAPL08022-E message to the console, syslog, and e

Strona 306

5. Troubleshooting3525.5 What To Do for a Program ErrorThe following describes what to do to handle errors that occur in an HDLM program. Figure 5-3:

Strona 307 - 4.4 HDLM Resident Processes

5. Troubleshooting3535.5.3 What To Do for the Program ErrorFollow the recommended actions for messages in 8. Messages.If the error occurs again after

Strona 308 - HDLM Operating Environment

5. Troubleshooting3545.6 What To Do for Other ErrorsWhen the cause of an error may be related to HDLM but is neither a path error nor an HDLM program

Strona 309

355Chapter6. Command ReferenceThis chapter describes the HDLM command (dlnkmgr) and its operations.6.1 Overview of the HDLM Command dlnkmgr6.2 clear (

Strona 310

6. Command Reference3566.1 Overview of the HDLM Command dlnkmgrThis section describes how to specify the HDLM command dlnkmgr and its subcommands (cal

Strona 311

6. Command Reference357Note:• Execute the command as a user with root permissions.• To specify a value that contains a space in its parameter, enclose

Strona 312

2. HDLM Functions162.7 Distributing a Load Using Load BalancingWhen the system contains multiple paths to a single LU, HDLM can distribute the load ac

Strona 313

6. Command Reference3586.2 clear (Returns the Path Statistics to the Initial Value)The dlnkmgr command's clear operation clears the statistics (I

Strona 314

6. Command Reference359(2) To display the format of the clear operation-helpDisplays the format of the clear operation.Example # /opt/DynamicLinkManag

Strona 315

6. Command Reference3606.3 help (Displays the Operation Format)The dlnkmgr command's help operation displays the list of operations available for

Strona 316

6. Command Reference361#Example 2The following example shows how to display the formats of multiple operations. # /opt/DynamicLinkManager/bin/dlnkmgr

Strona 317

6. Command Reference362help: Format dlnkmgr help { clear | offline | online | set | view | monitor }KAPL01001-I The HDLM command completed normall

Strona 318

6. Command Reference3636.4 offline (Places Paths Offline)The dlnkmgr command's offline operation places online paths offline. Specify the paths t

Strona 319

6. Command Reference364-hba host-port-number.bus-numberUse this parameter to place offline, at one time, all the paths that pass through a specific HB

Strona 320

6. Command Reference365KAPL01102-I All the paths which pass the specified HBA port will be changed to the Offline(C) status. Is this OK? [y/n]:yKAPL01

Strona 321

6. Command Reference366-chaid CHA-port-IDUse this parameter to place offline, at one time, all paths that pass through a specific CHA port. The comman

Strona 322

6. Command Reference367device.For SCSI-device-name, specify the value of Device displayed by executing the view operation as follows:# /opt/DynamicLin

Strona 323

2. HDLM Functions17Figure 2-5: Flow of I/O Data When the Load Balancing Function Is Not UsedWhen the load balancing function is not used, I/O operatio

Strona 324 - 18. Allocate the device ID

6. Command Reference368The following example shows how to display the format of the offline operation: # /opt/DynamicLinkManager/bin/dlnkmgr offline -

Strona 325

6. Command Reference369# /opt/DynamicLinkManager/bin/dlnkmgr view -path -stname | grep 9500V | grep 0A The above command will display information pert

Strona 326

6. Command Reference3706.5 online (Places Paths Online)The dlnkmgr command's online operation places offline paths online. Specify the paths to b

Strona 327

6. Command Reference371Use this parameter to place online, at one time, all the paths that pass through a specific HBA port. The command will place on

Strona 328

6. Command Reference3720 path(s) were not. Operation name = online#-cha -pathid AutoPATH_IDUse this parameter to place online, at one time, all the pa

Strona 329

6. Command Reference373CHA port whose CHA-port-ID is 00001.# /opt/DynamicLinkManager/bin/dlnkmgr offline -chaid 00001KAPL01104-I All the paths which p

Strona 330

6. Command Reference374-sExecutes the command without displaying the message asking for confirmation of command execution from the user. Specify this

Strona 331

6. Command Reference375ReferenceExecuting the view operation together with standard UNIX commands enables you to filter the path information listed fo

Strona 332 - /kernel/drv/dlmfdrv.conf)

6. Command Reference3766.6 set (Sets Up the Operating Environment)The dlnkmgr command's set operation sets the HDLM operating environment.6.6.1 F

Strona 333

6. Command Reference377Table 6-2: Default and Recommended Values-lb {on [-lbtype {rr|exrr|lio|exlio|lbk|exlbk}]|off}Enables or disables load balancing

Strona 335

2. HDLM Functions18Figure 2-6: Flow of I/O Data When the Load Balancing Function Is UsedWhen the load balancing function is used, I/O operations are d

Strona 336

6. Command Reference378exlio: The Extended Least I/Os algorithmlbk: The Least Blocks algorithmexlbk: The Extended Least Blocks algorithmThe type of al

Strona 337

6. Command Reference379hh:mm:ss#-elfs error-log-file-sizeSpecify a value from 100 to 2000000 (in kilobytes) for the size of the error log files. The t

Strona 338

6. Command Reference380As the amount of log information to be output increases, the amount of time before existing information is overwritten becomes

Strona 339

6. Command Reference381• When the checking interval has been specified before:The interval specified in the last timeThe explanation for the following

Strona 340

6. Command Reference382Operations.When you specify on, specify the checking interval by specifying the parameter immediately following on. If you do n

Strona 341 - (When Not Using Sun Cluster)

6. Command Reference383number-of-times-error-is-to-occur] | off }Enables or disables intermittent error monitoring.on: Enabledoff: DisabledIntermitten

Strona 342

6. Command Reference384monitoring interval and the number of times that the error is to occur:-intvl error-monitoring-intervalSpecify the monitoring i

Strona 343

6. Command Reference385Intermittent error monitoring will then resume with the changed settings. If you set the automatic failback function to off wh

Strona 344 - (When Using Sun Cluster)

6. Command Reference386Legend:AFB: Automatic failbackIEM: Intermittent error monitoring#1When this condition is not satisfied, the KAPL01080-W message

Strona 345

6. Command Reference387# /opt/DynamicLinkManager/bin/dlnkmgr set -iem on -intvl 20 -iemnum 2KAPL01049-I Would you like to execute the operation? Opera

Strona 346

2. HDLM Functions19owner path also varies depending on the LU. A non-owner path is a path that uses a CHA other than the owner controller (a non-owner

Strona 347

6. Command Reference388A temporary license key cannot be installed by using the dlnkmgr command's set operation.Example 1The following example sh

Strona 348

6. Command Reference389-category [[ss] [a] [ca]|all]Specifies the categories of audit log data to be collected. Table 6-8: Values Indicating Audit Log

Strona 349

6. Command Reference390-sExecutes the command without displaying the message asking for confirmation of command execution from the user. Specify this

Strona 350

6. Command Reference391 | -afb off | -iem on [ -intvl Error-Monitor-Interval ]

Strona 351

6. Command Reference392 all } (Default Value all) Facility-Name { user |

Strona 352

6. Command Reference3936.7 view (Displays Information)The dlnkmgr command's view operation displays HDLM program information, path information, L

Strona 353

6. Command Reference394[-srt {lu|cp}][-t](3) To display LU informationTo display LU information/opt/DynamicLinkManager/bin/dlnkmgr view -lu[-hdev host

Strona 354

6. Command Reference3956.7.2 ParametersThis section describes the parameters for the view operation, in the following order: (1) To display program in

Strona 355

6. Command Reference396Load Balance Settings for load balancing• Setting status:on: Enabledoff: Disabled• Algorithm:When the setting status of load ba

Strona 356

6. Command Reference397Path Health Checking• Settings for path health checking:on: Enabledoff: Disabled• Checking interval:When the setting of the pat

Strona 357

2. HDLM Functions20(2) When Using the Lightning 9900 Series, Lightning 9900V Series, Hitachi USP, Universal Storage Platform V/VM, Virtual Storage Pla

Strona 358

6. Command Reference398WakeupTime Startup time of the HDLM alert driverElogMem Size Size of error log memory for the HDLM alert driver in kilobytes-pd

Strona 359

6. Command Reference399#When you use cluster software, the settings of the cluster support function and the kinds of cluster servers are not displayed

Strona 360

6. Command Reference400#Example 2The following example shows how to display information about the HDLM manager: # /opt/DynamicLinkManager/bin/dlnkmgr

Strona 361

6. Command Reference401Example 6The following example shows how to display information about the audit log settings: # /opt/DynamicLinkManager/bin/dln

Strona 362

6. Command Reference402Use this parameter to display the model ID of the storage system in the product ID element of the DskName field. When this para

Strona 363

6. Command Reference403To display path information (by selecting a display item)-path -itemWhen you specify the -path parameter together with the -ite

Strona 364

6. Command Reference404#Because both PathID and Status are always displayed, you do not have to specify any parameters. In the sub-parameters followin

Strona 365 - 5. Troubleshooting

6. Command Reference405Use this parameter to sort the path information in ascending order, according to the specified sorting key.The sorting keys are

Strona 366

6. Command Reference406To display a summary of path information-path -cWhen you specify the -path parameter together with the -c parameter, only the P

Strona 367

6. Command Reference40711 or more characters in the product ID, the 8th and following characters are abbreviated to an ellipsis (...). The following

Strona 368

2. HDLM Functions21was distributed will be used. However, if a specified number of I/Os has been issued to a path, processing switches to the next pat

Strona 369

6. Command Reference408Displayed path informationTable 6-12: Displayed Path Information describes the displayed path information. The following explai

Strona 370 - 5.3.2 Obtain Path Information

6. Command Reference409PathStatus Status of the displayed paths. The displayed status indicates the following:•Online: All paths are available.•Reduce

Strona 371

6. Command Reference410iLU#iLU LU number of the storage system.This number combined with the storage system name (shown in DskName) identifies the LU

Strona 372

6. Command Reference411IO-Count#-- Total I/O count for the path, indicated by a decimal number. The maximum value that can be displayed is 232 - 1 (42

Strona 373

6. Command Reference412Legend:--: Not displayed#The path information is displayed only when a value is specified for the -path -item parameter.Table 6

Strona 374 - 5.5.1 Examining the Messages

6. Command Reference413#When a summary is displayed by specifying the -path -c parameter and there are more than 11 characters in the summary string,

Strona 375

6. Command Reference414(3) To display LU informationWhen displaying LU information, if the -item parameter, -c parameter, or the -c -item parameter is

Strona 376

6. Command Reference4150002 c6t2d1 sd62 000004 Online sd65 000010 Online0003 c6t2d2 sd63 000005 Online sd66 0000

Strona 377 - 6. Command Reference

6. Command Reference416In the sub-parameters, -hdev or -pathid, you can filter the LU information to be displayed. If you omit both parameters, the co

Strona 378

6. Command Reference417To display a summary of LU information-lu -cWhen the -c parameter is specified with the -lu parameter, a summary of LU configur

Strona 379 - ")

2. HDLM Functions22operation. For details on the set operation, see 6.6 set (Sets Up the Operating Environment).

Strona 380 - 6.2.2 Parameters

6. Command Reference418Omits the title for each information item.Example # /opt/DynamicLinkManager/bin/dlnkmgr view -lu -cProduct S/N LUs iLU

Strona 381

6. Command Reference419Displayed LU informationTable 6-17: Displayed LU Information describes the displayed LU information. The following explains the

Strona 382 - 6.3.2 Parameter

6. Command Reference420iLU LU number of the storage system.This number combined with the storage system name (shown in DskName) identifies the LU that

Strona 383

6. Command Reference421PathName#1-- The path name, which indicates a path. When you modify the system configuration or replace a hardware item, you sh

Strona 384

6. Command Reference422Legend:IO-Count#1-- Total I/O count for a path. The maximum value that can be displayed is 232 - 1 (4294967295). If the total I

Strona 385 - 6.4.2 Parameters

6. Command Reference423--: Not displayed#1 This information is displayed when one of the following conditions exist: - The user selected the item to b

Strona 386

6. Command Reference424Example# /opt/DynamicLinkManager/bin/dlnkmgr view -hba HbaID Port.Bus IO-Count IO-Errors Paths OnlinePathsPhysical Device0

Strona 387

6. Command Reference425CHA port. HDLM displays the unique CHA port ID assigned to each CHA port. This CHA port ID is used in monitor operations, and c

Strona 388

6. Command Reference426(Product), storage system serial numbers (S/N), and CHA port numbers (ChaPort).-tOmits the title for each information item.(6)

Strona 389

6. Command Reference427000000 c6t5d0 sd74 9970/9980.15001.0670000001 c6t5d1 sd75 9970/9980.15001.0671000002 c6t5d2 sd76 9970/9980.15001.06

Strona 390

2. HDLM Functions232.8 Performing Failovers and Failbacks Using Path SwitchingWhen the system contains multiple paths to an LU and an error occurs on

Strona 391

6. Command Reference428 [ic] [ie] [dnu] [iep] [pd] | all ] [ -hdev HostDeviceName

Strona 392 - 6.5.2 Parameters

6. Command Reference4296.8 monitor (Displays I/O Information at a Specified Interval)The dlnkmgr command's monitor operation displays I/O informa

Strona 393

6. Command Reference430are 500 or more paths for the -intvl parameter, the time interval of the monitor operation might be several seconds to 20 secon

Strona 394

6. Command Reference431Omits the title for each information item.Table 6-22: Items displayed as I/O information for each HBA portExample# /opt/Dynamic

Strona 395

6. Command Reference432format for the subsequent parameters are as follows:-intvl intervalSpecifies the interval at which I/O information is to be dis

Strona 396

6. Command Reference433ChaPort : 1RStartTime : yyyy/mm/dd hh:mm:ss ElapsedTime IO-Count IO-Errors00:00:30 1154 000:01:

Strona 398 - 6.6.2 Parameters

435Chapter7. Utility ReferenceThis chapter explains the utilities used by HDLM.7.1 Overview of the Utilities7.2 The DLMgetras Utility for Collecting H

Strona 399

7. Utility Reference4367.1 Overview of the UtilitiesHDLM provides the following utilities:• The DLMgetras utility for collecting HDLM error informatio

Strona 400

7. Utility Reference437Assisting Creation of the VxVM Configuration File.• The installhdlm utility for installing HDLMThis utility performs a new inst

Strona 401

2. HDLM Functions24A fatal error that might stop the system.ErrorA high-risk error, which can be avoided by performing a failover or some other counte

Strona 402

7. Utility Reference4387.2 The DLMgetras Utility for Collecting HDLM Error InformationThis utility collects information that is needed to analyze HDLM

Strona 403 - -intvl checking-interval

7. Utility Reference439Specify the output directory for the information that is to be collected by the DLMgetras utility for collecting HDLM error inf

Strona 404

7. Utility Reference440subdirectories. If no files are found in a specified directory, the utility does not perform file collection for that directory

Strona 405

7. Utility Reference441products other than HDLM. This file is output only when using the Hitachi Command Suite product that is the target for collecti

Strona 406

7. Utility Reference442opt/DynamicLinkManager/configdlmfdrv.unconf HDLM driver unconfiguration definition filedlmfdrv.unconf.bak Previous generation o

Strona 407 - 0, and then

7. Utility Reference443dlmfdrv.conf_oldbackup#3Backup of the existing dlmfdrv.conf file, taken when you perform an upgrade installation from HDLM 5.6.

Strona 408

7. Utility Reference444gabtabllthostsllttabvxfendgvxfenmode#5vxfentabI/O fencing function setup filesmnttab File system mount informationsyslog.conf s

Strona 409

7. Utility Reference445df-k.txt Mount informationdf-o.txt i node utilization statusdlmgetomtrace.dmp In-memory trace informationdlmls-la.txt List of d

Strona 410 - Value (severity) Explanation

7. Utility Reference446prtconf-pv.txt Hardware configuration information of a host (output results of the prtconf -pv command)prtconf-vP.txt List of d

Strona 411 - -audfac facility-value

7. Utility Reference447VXVM_vxdmp.txt /dev/vx/dmp directory listVXVM_vxrdmp.txt /dev/vx/rdmp directory listVXVM_vxdsk.txt /dev/vx/dsk directory listVX

Strona 412

2. HDLM Functions25Figure 2-8: Path Switching(2) Automatic FailbacksWhen a path recovers from an error, HDLM can automatically place the recovered pat

Strona 413

7. Utility Reference448var/adm/syslog syslog.log.txt Log of error messagesThe output destination is either /var/vxvm/vxconfigd.log or /var/adm/syslog/

Strona 414

7. Utility Reference449#1etc/lvm#6md.tab SDS or SVM input parameter filemd.cf SDS or SVM configuration backup filemddb.cf Information on SDS or SVM st

Strona 415 - 6.7.1 Format

7. Utility Reference450An output directory is created in the specified directory when you extract the getras.tar.Z file.#2The value N depends on the s

Strona 416

7. Utility Reference4517.3 The dlmcfgmgr Utility for Managing the HDLM ConfigurationThis utility makes the HDLM driver recognize the contents of the H

Strona 417 - 6.7.2 Parameters

7. Utility Reference4527.3.2 Parameters-aApplies the contents of the HDLM driver configuration definition file (/kernel/drv/dlmfdrv.conf) to HDLM driv

Strona 418

7. Utility Reference453• You must restart the host after performing an upgrade installation or re-installation. LUs will not be added or deleted dynam

Strona 419

7. Utility Reference454occurs:-For the LU, you changed the LUN mapping, the mapping-destination storage port, or the HBA port on the recognizing host.

Strona 420

7. Utility Reference4557.4 The dlminstcomp HDLM Component Installation UtilityThis utility complements HDLM installation. Execute this utility when bo

Strona 421

7. Utility Reference4567.5 The dlmlisthdev Utility for Assisting HDLM TransitionsUse the dlmlisthdev utility when migrating to HDLM 6.5.1 from HDLM 04

Strona 422

7. Utility Reference457configuration in HDLM 6.5.1.5. Create a list that shows the correspondences between the logical device file names of the HDLM d

Strona 423

2. HDLM Functions26Storage Platform V/VM, Virtual Storage Platform, Hitachi AMS2000 Series, or Hitachi SMS is being used, all the paths are owner path

Strona 424

7. Utility Reference458The file that stores the output result of the dlnkmgr command's view -path operation must be created in a directory that i

Strona 425

7. Utility Reference4597.6 The dlmsetconf Utility for Creating the HDLM Driver Configuration Definition FileThis dlmsetconf utility obtains device inf

Strona 426

7. Utility Reference460In the subsequent explanations, the configuration definition file is indicated as the HDLM driver configuration definition file

Strona 427

7. Utility Reference461Depending on the contents of the HDLM driver unconfiguration definition file (/opt/DynamicLinkManager/config/dlmfdrv.unconf) th

Strona 428

7. Utility Reference462Example 4The -u parameter is specified:Defines a non- HDLM-managed LU based on the contents of the definitions in the HDLM driv

Strona 429

7. Utility Reference463definition file (/kernel/drv/dlmfdrv.conf) the utility adds an entry (that is, a definition) to the definition of the LU for wh

Strona 430 - -path -c parameter

7. Utility Reference464option specified, and then restart the host.• If the below message appears after you execute the dlmsetconf utility, it means t

Strona 431

7. Utility Reference4657.7 The dlmvxexclude Utility for Assisting Creation of the VxVM Configuration FileThis utility outputs the file (vxvm_exclude.t

Strona 432

7. Utility Reference466# /opt/DynamicLinkManager/bin/dlmvxexclude -d /tmpDisplay exampleExampleThe entries for the following devices are output:• sd o

Strona 433

7. Utility Reference467• Do not use the output result of the dlmvxexclude utility as is for the vxvm.exclude file. If a device other than the HDLM-man

Strona 434 - -item parameter

2. HDLM Functions27Executing the online operation places the offline path online. For details on the online operation, see 6.5 online (Places Paths On

Strona 435

7. Utility Reference4687.8 The installhdlm Utility for Installing HDLMYou can use the installhdlm utility to perform a new installation, upgrade insta

Strona 436

7. Utility Reference469Table 7-4: Keys that Can Be Defined in the [INSTALLATION_SETTINGS] SectionKey name#1Explanation#2Required or optional? Maximum

Strona 437 - CLPR clpr

7. Utility Reference470Legend:Optional: If you omit the key name and value, the default is used.However, for an upgrade installation or re-installatio

Strona 438 - -pathid AutoPATH_ID

7. Utility Reference471Table 7-5: Keys that Can Be Defined in the [ENVIRONMENT_SETTINGS] SectionKey name#1Explanation#2Required or optional? Maximum l

Strona 439

7. Utility Reference472trace_level Specify the output level for traces.You can specify a value from 0 to 4. The default is 0.Optional Optional 1trace_

Strona 440

7. Utility Reference473Legend:Optional: If you omit the key name and value, the following value is used:• For a new installationThe default is used.•

Strona 441 - Displayed LU information

7. Utility Reference474For details on the settings functionality, see 6.6 set (Sets Up the Operating Environment).#3You can specify this key only in t

Strona 442

7. Utility Reference4757.8.4 About the Log FileDuring an unattended installation, information about installation progress is output to the log file in

Strona 443

7. Utility Reference4767.9 installux.sh Utility for HDLM Common InstallerThis utility determines what OS HDLM will be installed on, and installs the c

Strona 444

477Chapter8. MessagesThis chapter describes the format and meaning of the message IDs, and also the terms used in the messages and message explanation

Strona 445

iPrefaceThis manual describes the functions and use of the following program products.• Hitachi Dynamic Link ManagerIntended readersThis manual is int

Strona 446

2. HDLM Functions28error occurred on the path.The (E) in Offline(E) indicates the error attribute, which indicates that an error occurred in the path.

Strona 447

8. Messages4788.1 Before Viewing the List of MessagesThis section explains the following information that is needed to locate messages and understand

Strona 448

8. Messages479• HDLM driver (filter component)• HDLM alert driver• HDLM management target

Strona 449

8. Messages4808.2 KAPL01001 to KAPL02000KAPL01001-IThe HDLM command completed normally. Operation name = aa...aa, completion time = bb...bbDetailsThe

Strona 450

8. Messages481Detailsaa...aa: clear, set, monitor,online, offline, or viewbb...bb: Specified parameterActionExecute help operation-name of the HDLM co

Strona 451 - 6.8.2 Parameters

8. Messages482KAPL01009-WA parameter value is invalid. Operation name = aa...aa, parameter = bb...bb, parameter value = cc...cc, Valid value = dd...dd

Strona 452

8. Messages483KAPL01014-WNo authority to execute the HDLM command. Operation name = aa...aaDetailsYou do not have the administrator permissions necess

Strona 453

8. Messages484the corresponding CHA_ID, and retry the operation. For details on the view operation, see 6.7 view (Displays Information).KAPL01018-WThe

Strona 454

8. Messages485KAPL01021-ECannot execute the HDLM command due to insufficient memory.DetailsMemory required for HDLM command processing could not be al

Strona 455

8. Messages486PathID = aa...aa Would you like to continue the processing of the online operation? [y/n]:DetailsA path that cannot be placed Online was

Strona 456

8. Messages487cc...cc: Duplicate parameter valueActionDelete the duplicate parameter value, and then retry.KAPL01045-WToo many parameter values are sp

Strona 457 - 7. Utility Reference

2. HDLM Functions29LU.#2When the following conditions are satisfied, a path that has been determined to have an intermittent error also becomes subjec

Strona 458 - 7.1 Overview of the Utilities

8. Messages488Up the Operating Environment).KAPL01050-IThe currently selected paths will be changed to the Online status. Is this OK? [y/n]:DetailsThe

Strona 459

8. Messages489KAPL01053-IIf you are sure that there would be no problem when the path is placed in the Offline(C) status, enter y. Otherwise, enter n.

Strona 460 - 7.2.2 Parameters

8. Messages490KAPL01056-IIf you are sure that there would be no problem when all the paths which pass the specified aa...aa are placed in the Offline(

Strona 461

8. Messages491KAPL01059-WCannot specify the parameter aa...aa at the same time if you specify parameter bb...bb and parameter value cc...cc. Operation

Strona 462

8. Messages492ActionNone. For details on the online operation, see 6.5 online (Places Paths Online). For details on the offline operation, see 6.4 off

Strona 463

8. Messages493Obtain a valid license key, and then retry.KAPL01071-IThe permanent license was installed.DetailsThe license was renewed and is register

Strona 464

8. Messages494Re-install HDLM.KAPL01076-IThe permanent license has been installed.DetailsYou need not install a license because a permanent license ha

Strona 465

8. Messages495number-of-times-error-is-to-occur-for-intermittent-error-monitoring).KAPL01081-EThe license key file is invalid. File name = aa...aaDeta

Strona 466

8. Messages496aa...aa: /var/tmp/hdlm_licenseActionIf a license key file exists, delete it./var/tmp/hdlm_licenseKAPL01088-WThe specified parameter valu

Strona 467

8. Messages497aa...aa: Path IDbb...bb: Code showing reason for errorActionResolve the error in the relevant path, and then re-execute.KAPL01091-EThe O

Strona 468

2. HDLM Functions302.9 Intermittent Error Monitoring (Functionality When Automatic Failback Is Used)An intermittent error means an error that occurs i

Strona 469

8. Messages498DetailsAn attempt to recover the path failed because the correct disk label has not been set in the LU for the path to be put online. aa

Strona 470

8. Messages499aa...aa: Code showing the reason for the errorActionRe-execute the command. If the same error occurs again, execute the DLMgetras utilit

Strona 471

8. Messages500DetailsMultiple paths will be collectively placed Offline(C) because the -hbaid or -chaid parameter was specified. To collectively place

Strona 472

8. Messages501want to terminate processing, enter n.KAPL01112-EAn attempt to connect to the HDLM driver has failed. Operation name = aa...aaDetailsHDL

Strona 473 - 7.3.1 Format

8. Messages502KAPL01116-WThe audit log configuration file is invalid. Restart the HDLM Manager, and execute the "dlnkmgr view -sys -audlog"

Strona 474 - 7.3.2 Parameters

8. Messages503KAPL01120-WA storage subsystem model ID could not be displayed. Details = aa...aa, bb...bbDetailsA storage system model ID could not be

Strona 475

8. Messages5048.3 KAPL03001 to KAPL04000KAPL03001-IHDLM API information - aa...aaDetailsThis information is required for resolving problems.aa...aa: T

Strona 476 - daemon is output to

8. Messages505aa...aa: API trace error informationActionExecute the DLMgetras utility for collecting HDLM error information, and then contact your HDL

Strona 477 - 7.4.2 Parameter

8. Messages506contract for HDLM. For details on the DLMgetras utility, see 7.2 The DLMgetras Utility for Collecting HDLM Error Information.

Strona 478 - 7.5.2 Parameters

8. Messages5078.4 KAPL04001 to KAPL05000KAPL04001-IHDLM manager started.ActionNone.KAPL04002-ECould not start the HDLM manager.DetailsThe HDLM manager

Strona 479

2. HDLM Functions312.9.3 Intermittent Error Monitoring ActionsIntermittent error monitoring is performed on each path, and it automatically starts as

Strona 480

8. Messages508aa...aa: Option definition file nameActionCheck whether another program is currently using this file (for example, the file is being ope

Strona 481 - Configuration Definition File

8. Messages509KAPL04012-ECould not create a communication pipe. RC = aa...aaDetailsHDLM manager could not start normally because it was unable to crea

Strona 482 - 7.6.2 Parameters

8. Messages510DetailsAn attempt to read the log information from the alert driver failed.aa...aa: API return code (decimal (base-10) number)ActionExec

Strona 483

8. Messages511DLMgetras Utility for Collecting HDLM Error Information.KAPL04024-CA critical error occurred in the HDLM manager. (aa...aa)DetailsThis i

Strona 484

8. Messages512Install a permanent license by the expiration day.KAPL04028-EThe temporary license expired.ActionInstall a permanent license.KAPL04029-E

Strona 485

8. Messages513KAPL04034-EAn attempt to create the option definition file has failed.DetailsAn attempt to re-create an option definition file (/etc/opt

Strona 486

8. Messages514aa...aa: Start or stopActionNone.KAPL04045-IHDLM SNMP TRAP was sent. Trap ID = aa...aa, IP Address = bb...bb, Port Number= cc...cc, Comm

Strona 487 - 7.7.2 Parameters

8. Messages5158.5 KAPL05001 to KAPL06000KAPL05003-IThe HDLM driver (filter component) was successfully attached to Disk (aa...aa), Partition (bb...bb)

Strona 488

8. Messages516aa...aa: Minor number of the sd or ssd device (decimal number)bb...bb: Slice number (decimal number)cc...cc: Error code (hexadecimal num

Strona 489

8. Messages517KAPL05019-IThe FO processing in the path (aa...aa) finished. The I/O request was processed in the path (bb...bb).Detailsaa...aa: Path ID

Strona 490 - 7.8.2 Parameters

2. HDLM Functions32(2) When an Intermittent Error Does Not OccurIf an error does not occur in the path the specified number of times within the specif

Strona 491

8. Messages518cc...cc: 0 (fixed)ActionCheck the message of the HDLM command (dlnkmgr) or the HDLM manager, and then take the appropriate action. If yo

Strona 492

8. Messages519KAPL05041-EThe contents of the configuration definition file (dlmfdrv.conf) are invalid. (Instance = aa...aa) Execute the dlmsetconf com

Strona 493

8. Messages520The instance number of the HDLM filter driver instance that you tried to attach is already being used.aa...aa: Instance number (decimal

Strona 494

8. Messages521kernel/drv/dlmndrv.conf) of the filter driver or nexus driver is invalid.aa...aa: Driver nameActionCheck whether the path is correctly c

Strona 495

8. Messages522aa...aa: Path IDbb...bb: Error information (internal code)ActionStop any applications that are using the HDLM devices, and then re-execu

Strona 496

8. Messages523KAPL05904-EFailed to set device name. Execute the DLMgetras utility to collect error information, and then contact your vendor or mainte

Strona 497 - 7.8.4 About the Log File

8. Messages5248.6 KAPL06001 to KAPL07000KAPL06003-IInitialization of the HDLM alert driver (aa...aa) was successful.Detailsaa...aa: Address of the tab

Strona 498 - 7.9.3 Log file

8. Messages525ActionNone.KAPL06009-IInvalid IOCTL (aa...aa) was received. The processing is canceled.DetailsA request to the alert driver was made wit

Strona 499 - 8. Messages

8. Messages526written is discarded.Review the actual memory size when another error does not occur.When the actual memory size is insufficient, increa

Strona 500

8. Messages5278.7 KAPL07001 to KAPL08000KAPL07819-IData for maintenance: aa...aa bb...bb cc...cc dd...dd.DetailsThis message is generated by the core

Strona 501 - • HDLM management target

2. HDLM Functions33and then manually place the path online.(3) When the Conditions for an Intermittent Error Are Changed During Error MonitoringWhen t

Strona 502 - 8.2 KAPL01001 to KAPL02000

8. Messages5288.8 KAPL08001 to KAPL09000KAPL08019-EThe path (aa...aa) detected an error (bb...bb). (cc...cc)DetailsAn error occurred in the path. The

Strona 503 - KAPL01008-W

8. Messages529ee...ee: Target ID (same as PathName of view -path) (hexadecimal number)ff...ff: HLU number (same as PathName of view -path) (hexadecima

Strona 504 - KAPL01013-E

8. Messages530KAPL08027-EA path was excluded from the items subject to automatic failback. PathID = aa...aaDetailsA path was excluded from being subje

Strona 505 - KAPL01016-W

8. Messages5318.9 KAPL09001 to KAPL10000KAPL09002-EThe disk does not have sufficient free space.DetailsThe file system of the installation does not ha

Strona 506 - KAPL01019-W

8. Messages532Manually cancel the PP name registration, and then uninstall Hitachi Network Objectplaza Trace Library 2. If the attempt to cancel the r

Strona 507

8. Messages533An attempt to copy a file related to HDLM to the directory of Hitachi Command Suite products other than HDLM has failed.ActionIf you det

Strona 508 - KAPL01044-W

8. Messages534ActionSee 3.1.1 Hosts and OSs Supported by HDLM and install HDLM in a supported OS system.KAPL09029-EThis version of HDLM cannot be upda

Strona 509 - KAPL01049-I

8. Messages535None.KAPL09077-IThe temporary license was installed. The license expires on aa...aa.DetailsA temporary license was installed.aa...aa: Ye

Strona 510 - KAPL01052-I

8. Messages536The emergency license has been installed.aa...aa: Year (4 digits)/month (01-12)/day (01-31)ActionInstall a permanent license by the expi

Strona 511 - KAPL01055-I

8. Messages537You need to install a license because the license information cannot be acquired.ActionIn the case that the license key file is being pl

Strona 512 - KAPL01058-W

2. HDLM Functions34If you want to check whether intermittent error monitoring is being performed for the path, check the IEP item displayed when the d

Strona 513 - KAPL01061-I

8. Messages538Place the correct license key file in the designated directory (/var/tmp/hdlm_license), in a user-specified directory or with a user-spe

Strona 514 - KAPL01070-E

8. Messages539DetailsAn attempt to delete the license key file has failed.aa...aa: /var/tmp/hdlm_licenseActionIf a license key file exists, delete it.

Strona 515

8. Messages540ActionPlease perform the utility for collecting HDLM error information (DLMgetras), and acquire obstacle information, and then contact y

Strona 516 - KAPL01080-W

8. Messages541KAPL09148-WCould not modify file. File name = aa...aa, Details = bb...bb. Please contact product support.DetailsAn HDLM driver configura

Strona 517 - KAPL01084-W

8. Messages542KAPL09149-EAn attempt to update the file has failed. File name = aa...aa, Details = bb...bb. Please contact product support.DetailsAn HD

Strona 518 - KAPL01090-E

8. Messages543dlmfdrv.conf) by executing dlmsetconf utility.2. When you want to specify that a device is not to be managed by HDLM, edit the HDLM driv

Strona 519 - KAPL01093-E

8. Messages544More than two parameters have been specified for the installhdlm utility for installing HDLM.ActionMake sure that the parameters for ins

Strona 520 - KAPL01096-E

8. Messages545ActionFollow the message output at the same time.KAPL09203-WThere is no license key file. File name = aa...aaDetailsThere is no license

Strona 521 - KAPL01102-I

8. Messages546KAPL09208-EThere is no license key file. Renewal of the license key will now stop. File name = aa...aaDetailsThere is no license key fil

Strona 522 - KAPL01107-I

8. Messages547Check the error message that was output just before this message, and then perform the action indicated in that error message.KAPL09213-

Strona 523 - KAPL01115-W

2. HDLM Functions35When you disable the intermittent error monitoring function, information about paths not subject to automatic failback will be rese

Strona 524 - KAPL01119-W

8. Messages548You do not have write permission for the file system of the /var/tmp directory. Make sure you have access permissions for the file syste

Strona 525 - KAPL01121-W

8. Messages549ActionIf the error code is 9001,-1:You do not have read permissions for the installation information settings file. Make sure that you h

Strona 526 - 8.3 KAPL03001 to KAPL04000

8. Messages550maintenance contract for HDLM.KAPL09220-WThe composition of the installation information settings file is invalid. Error Code = aa...aa

Strona 527 - KAPL03999-E

8. Messages551ActionSpecify the revised installation information settings file and then retry the operation.KAPL09228-WThe definition of the installat

Strona 528

8. Messages552bb...bb: Return value (decimal number) of the executed processingcc...cc: Line number (decimal number) of an installation information se

Strona 529 - 8.4 KAPL04001 to KAPL05000

8. Messages553aa...aa: Error number (decimal number) that specifies the executed processingbb...bb: Return value (decimal number) of the executed proc

Strona 530 - KAPL04011-E

8. Messages554You do not have write permission for the installhdlm.log file.Modify your access permissions as necessary, and then retry the operation.

Strona 531 - KAPL04019-E

8. Messages555DetailsThe host will restart because restart was specified in the installation information settings file.ActionNone.KAPL09241-WAn attemp

Strona 532 - KAPL04023-E

8. Messages556The HDLM component installation utility (dlminstcomp) finished successfully.ActionNone.KAPL09246-EAn attempt to install an HDLM componen

Strona 533 - KAPL04027-I

8. Messages557An SP cannot be applied because HDLM is not installed on the system.ActionCheck whether HDLM has been correctly installed.KAPL09504-EThe

Strona 534

2. HDLM Functions362.10 Detecting Errors by Using Path Health CheckingHDLM can check the status of paths to which I/Os are not issued, at regular inte

Strona 535

8. Messages558DetailsA newer version of the SP (bb...bb) is already installed. Installation of SP (aa...aa) is stopped.aa...aa: The version of the SP

Strona 536 - KAPL04045-I

8. Messages559• If an installation is performed by using files copied from the DVD-ROM, re-copy all of the DVD-ROM files. After that, confirm the perm

Strona 537 - 8.5 KAPL05001 to KAPL06000

8. Messages5608.10 KAPL10001 to KAPL11000KAPL10001-WNo parameter has been specified.DetailsNo directory to which the collected information will be out

Strona 538 - KAPL05018-W

8. Messages561ActionCheck the parameters of the DLMgetras utility for collecting HDLM error information, and then retry. For details on the DLMgetras

Strona 539 - KAPL05023-E

8. Messages562DetailsYou do not have write permission for the specified directory, or the creation of a subdirectory of the specified directory failed

Strona 540 - KAPL05040-E

8. Messages563Two or more file names or directory names exist in the file for defining the information to be collected.aa...aa: Line number of the fil

Strona 541 - KAPL05411-W

8. Messages564bb...bb: Indicated contents in a lineActionAfter the DLMgetras utility for collecting HDLM error information terminates, check the conte

Strona 542 - KAPL05437-E

8. Messages565DetailsA root "/" cannot be specified in a directory to which collected information is output. ActionCheck the parameters of t

Strona 543 - KAPL05452-W

8. Messages566KAPL10022-IThe utility for collecting HDLM error information completed normally.DetailsError information has been collected.ActionNone.

Strona 544 - KAPL05903-E

8. Messages567The file to collect does not exist.aa...aa: File to collectActionNone.KAPL10034-EThe file could not be copied. Filename = aa...aa, Detai

Strona 545 - KAPL05921-E

2. HDLM Functions372.11 Error ManagementFor troubleshooting purposes, HDLM collects information and stores it into log files. The error information to

Strona 546 - 8.6 KAPL06001 to KAPL07000

8. Messages568company if you have a maintenance contract for HDLM.KAPL10049-IError information collection command = aa...aa, Return value = bb...bb, E

Strona 547 - KAPL06013-E

8. Messages569ActionCheck the capacity of the root file system or the file system including the directory specified by the -d option. Check the memory

Strona 548 - KAPL06014-E

8. Messages570KAPL10224-EAn error occurred when creating the configuration definition information.DetailsAn attempt to create a configuration definiti

Strona 549 - 8.7 KAPL07001 to KAPL08000

8. Messages571KAPL10229-EInternal processing error.DetailsAn internal processing error occurred.ActionInternal processing error. Contact your HDLM ven

Strona 550 - 8.8 KAPL08001 to KAPL09000

8. Messages572cc...cc: Errno stringActionRemove the error by referencing Errno, and then retry.KAPL10235-WGet symbolic link file(aa...aa) status faile

Strona 551 - KAPL08026-E

8. Messages573KAPL10238-WThe device (aa...aa) could not be opened. Errno = bb...bb (cc...cc)DetailsAn attempt to open an sd or ssd device failed.aa...

Strona 552 - PathID = aa...aa

8. Messages574HDLM-managed sd or ssd device are deleted at reboot. To configure HDLM, enter y if you want to execute the dlmsetconf utility, enter n t

Strona 553 - 8.9 KAPL09001 to KAPL10000

8. Messages575KAPL10252-WAn attempt to read the contents of symbolic link aa...aa failed. Function = readlink, errno = bb...bb (cc...cc)DetailsAn atte

Strona 554 - KAPL09024-E

8. Messages576Processing will stop because an incorrect value was entered three or more times for the message confirming the execution of the dlmsetco

Strona 555 - KAPL09027-E

8. Messages577If the disk indicated in Device is the LU that was dynamically deleted, no action is required. To prevent this message from being output

Strona 556

iiproblems that you might encounter.6. Command ReferenceChapter 6 describes all the HDLM commands.7. Utility ReferenceChapter 7 describes the HDLM uti

Strona 557

2. HDLM Functions38Figure 2-13: Flow of Data When Collecting Error InformationLogs might be collected in layers below HDLM, such as for the SCSI drive

Strona 558

8. Messages578DetailsAn attempt to acquire HDevList failed because the dlnkmgr view -path command failed.ActionRemove from the dlnkmgr view -path comm

Strona 559 - KAPL09112-E

8. Messages579KAPL10328-EThe entered value is invalid. The HDLM-configuration definition utility processing will now stop. Execute the HDLM-configurat

Strona 560 - KAPL09115-W

8. Messages580DetailsDisplays how to use dlmcfgmgr.ActionSpecify appropriate parameters, and then retry. For details on the dlmcfgmgr utility, see 7.3

Strona 561 - KAPL09137-W

8. Messages581DetailsA message could not be acquired from the message catalog.aa...aa: Errnobb...bb: Errno stringActionRemove the error by referencing

Strona 562 - KAPL09143-E

8. Messages582KAPL10376-EThe device (aa...aa) could not be opened. ErrorCode = bb...bb (cc...cc)DetailsAn attempt to open the device managing the HDLM

Strona 563 - KAPL09148-W

8. Messages583Contact your HDLM vendor or the maintenance company if there is a maintenance contract for HDLM.KAPL10380-EA parameter is invalid. Execu

Strona 564 - KAPL09176-I

8. Messages584KAPL10384-EThe value of the aa...aa property in the configuration definition file (bb...bb) is invalid. Execute the DLMgetras utility to

Strona 565 - KAPL09188-W

8. Messages585DetailsThe property value of the path described in the configuration definition file has the same value as a different LU path managed b

Strona 566

8. Messages586Check the capacity of the root file system or the file system including the file. Check the memory capacity which can be used.KAPL10391-

Strona 567

8. Messages587ActionContact your HDLM vendor or the maintenance company if there is a maintenance contract for HDLM.KAPL10396-WNo authority to execute

Strona 568

2. HDLM Functions39details, see the Solaris documentation.2.11.1 Types of Collected LogsHDLM collects information on detected errors and trace informa

Strona 569 - KAPL09215-E

8. Messages588KAPL10701-Iusage: dlmvxexclude [ -d dir | -h ]DetailsDisplays how to use dlmvxexclude.ActionSpecify appropriate parameters, and then ret

Strona 570 - KAPL09217-E

8. Messages589for Assisting Creation of the VxVM Configuration File.KAPL10705-EInternal processing error.DetailsAn internal error occurred while the d

Strona 571 - KAPL09219-E

8. Messages590KAPL10709-EAn error occurred when creating the file aa...aa.DetailsAn attempt to create a file has failed.aa...aa: File nameActionCheck

Strona 572 - KAPL09227-W

8. Messages591Check the system configuration and then execute the dlmsetconf utility for creating the HDLM driver configuration definition file.KAPL10

Strona 573 - KAPL09230-W

8. Messages592DetailsThe specified file name is not the name of a directory.aa...aa: Directory nameActionSpecify the correct directory.KAPL10717-EThe

Strona 574 - KAPL09233-W

8. Messages593KAPL10720-WThe entered value is invalid. Re-enter [y/n]:DetailsAn incorrect value was entered for the message confirming execution of th

Strona 575 - KAPL09235-E

8. Messages594Configuration File.KAPL10951-IThe LU (LDEV = aa...aa) was successfully deleted.DetailsThe LU was successfully deleted.aa...aa: LDEV name

Strona 576 - KAPL09239-I

8. Messages595KAPL10954-EMultiple paths have the same property (aa...aa) value for the LU (LDEV = bb...bb) that will be deleted. The LU configuration

Strona 577 - KAPL09243-I

8. Messages5968.11 KAPL11001 to KAPL12000KAPL11901-Iaa...aa has started.DetailsThe operation has started on the host.aa...aa: Operation (character str

Strona 578 - KAPL09501-E

8. Messages597None.KAPL11903-Iaa...aa has completed normally.DetailsThe operation has completed normally on the host.aa...aa: Any of the following ope

Strona 579 - KAPL09510-E

2. HDLM Functions40#When you want to configure the system so that HDLM messages are output to syslog, specify user for the facility in the /etc/syslog

Strona 580 - KAPL09603-E

8. Messages598• Clear Data• Get HDLM Driver Status• Get HDLM Manager Status• Get HDLM Alert Driver Status•Online• Offline• Get SNMP Trap Information•

Strona 581 - KAPL09604-E

8. Messages599KAPL11907-IXML reception - aa...aaDetailsThis information is required for resolving problems.aa...aa: XML information (character string)

Strona 582 - 8.10 KAPL10001 to KAPL11000

8. Messages6008.12 KAPL13001 to KAPL14000KAPL13601-WThe audit log configuration file does not exist. Restart the HDLM Manager, and execute the "d

Strona 583 - KAPL10008-W

8. Messages601An internal error occurred during processing to read the audit log configuration file.ActionContact your HDLM vendor or the maintenance

Strona 584 - KAPL10011-W

8. Messages6028.13 KAPL15001 to KAPL16000KAPL15010-WThe HDLM utility was executed by the user who does not have the authority. Command Line = aa...aaD

Strona 585 - KAPL10013-W

8. Messages603aa...aa: Name of the utility that the user executedKAPL15026-IInformation about exclusion from VxVm management was successfully output.

Strona 586 - KAPL10016-W

8. Messages604dd...dd: Command that the user executedKAPL15104-Waa...aa path(s) were failed to place bb...bb. Command Line = cc...ccDetailsaa...aa: Nu

Strona 587 - KAPL10021-I

8. Messages605aa...aa: Command that the user executedKAPL15111-WThe HDLM command was started or stopped by the user who does not have the authority. C

Strona 588

8. Messages6068.14 Return Codes for Hitachi Command Suite Common Agent ComponentWhen an operation requested of HDLM from Global Link Manager terminate

Strona 589 - KAPL10036-E

8. Messages607ActionClick Refresh to update the host information, check the path status, and then retry the offline operation.1015DetailsThe Offline p

Strona 590 - KAPL10202-W

2. HDLM Functions41• Collects no error information.• Collects error information from the Error level and higher.• Collects error information from the

Strona 591 - KAPL10223-E

8. Messages608maintenance contract for HDLM. For details on the DLMgetras utility, see 7.2 The DLMgetras Utility for Collecting HDLM Error Information

Strona 592 - KAPL10228-W

8. Messages609An attempt to recover the path failed because of insufficient memory. Online processing will be stopped if online processing is running

Strona 593 - (cc...cc)

8. Messages6101032DetailsAn attempt to recover the path failed because the correct disk label has not been set in the LU for the path to be put online

Strona 594 - Errno = bb...bb (cc...cc)

8. Messages611utility for collecting HDLM error information to collect the error information, and then contact your HDLM vendor or maintenance company

Strona 595 - KAPL10242-I

8. Messages612ActionRefresh the host information, check the path status, and then perform the operation again.1045DetailsA parameter is invalid.Action

Strona 596 - KAPL10251-W

613AppendixesA. Sun Cluster 3.2 CommandsB. Functional Differences Between Versions of HDLMC. Glossary

Strona 597 - KAPL10255-E

A. Sun Cluster 3.2 Commands614A. Sun Cluster 3.2 CommandsTable A-1: Correspondence Between Sun Cluster 3.1 Commands and Sun Cluster 3.2 Commands shows

Strona 598 - Device = dd...dd

A. Sun Cluster 3.2 Commands615#1Execute this command in step 13 in (10) Set Up Sun Cluster of 3.5.1 Preparations for a New Installation of HDLM and in

Strona 599 - KAPL10298-E

B. Functional Differences Between Versions of HDLM616B. Functional Differences Between Versions of HDLMThis section explains the functional difference

Strona 600 - KAPL10320-E

C. Glossary617C. GlossaryThis glossary explains the terms used in this manual.Aautomatic failbackA function for checking the status of paths at regula

Strona 601 - KAPL10368-I

2. HDLM Functions422.12 Collecting Audit Log DataHDLM and other Hitachi storage-related products provide an audit log function so that compliance with

Strona 602 - KAPL10372-E

C. Glossary618DDevA logical division of an LU that HDLM controls and operates. A Dev is equivalent to a slice or a partition in Solaris.In Solaris, ea

Strona 603 - KAPL10375-W

C. Glossary619failoverA function for switching to another normal path if there is an error in the current access path, thereby enabling the system to

Strona 604 - KAPL10379-E

C. Glossary620A host device name is assigned using the cUtXdY format.The variables used in cUtXdY indicate the following:U: Controller number reserved

Strona 605 - KAPL10383-E

C. Glossary621• The Extended Least Blocks algorithmlocal boot disk environmentAn environment in which a boot disk is located on the host.logical devic

Strona 606 - KAPL10387-W

C. Glossary622(See also: owner path, non-owner controller)owner pathA path that passes through an owner controller for an LU in the Thunder 9500V Seri

Strona 607 - KAPL10390-W

C. Glossary623RreservationThe reservation function enables a host to declare that it has exclusive rights to use a particular LU, and prevents other h

Strona 609 - KAPL10398-E

625IndexSymbols/etc/system filesetup 105/kernel/drv/sd.conf filesetup 104Aabbreviations defined iiiactive host 53addinga new logical unit 292audit log

Strona 610 - KAPL10704-I

Index626cUtXdYsZ 14Ddefault and recommended values 377Dev 7, 8, 618Dev number 618diagram conventions viidirectory to which collected information is ou

Strona 611 - KAPL10708-E

Index627path error 347HBA 8HBA (Host Bus Adapter) 619hbsa.tar.Z 440HDev 10HDevName 346HDLMfeatures 4functions 5installing 101, 110, 118installing with

Strona 612 - KAPL10712-E

2. HDLM Functions43The categories of audit log data that can be collected differ depending on the product. The following sections explain only the cat

Strona 613 - KAPL10716-E

Index628INSTALLATION_SETTINGS 468installhdlm 468installhdlm.log 475installingHDLM 110, 118HDLM with Sun Cluster 118HDLM without Sun Cluster 110install

Strona 614 - KAPL10719-I

Index629Oobtainingpath information 348program information 352offline 23, 363offline(C) status 27offline(E) status 27online 23, 370online status 27onli

Strona 615 - KAPL10723-I

Index630HDLM manager 283in Solaris 10 270statistics 358clearing to the initial value 358status transitions 28stoppingHDLM manager 283storage systems 2

Strona 616 - KAPL10953-E

2. HDLM Functions44Table 2-9: Categories and Audit Events that Can Be Output to the Audit LogCategory Explanation Audit eventSeverity#1Message IDStart

Strona 617 - KAPL10954-E

2. HDLM Functions45ConfigurationAccess Viewing or updating configuration informationInitialization of path statistics was successful.6 KAPL15101-IInit

Strona 618 - 8.11 KAPL11001 to KAPL12000

2. HDLM Functions46#1The severity levels are as follows:3: Error, 4: Warning, 6: Informational#2If you use Ctrl + C to cancel the DLMgetras utility fo

Strona 619 - KAPL11904-E

2. HDLM Functions47example, an HDLM utility is executed from external media.##:The following audit log data is output:• Categories: StartStop, Authent

Strona 620 - KAPL11906-I

iiiConventions: AbbreviationsThis manual uses the following abbreviations for product names.Abbreviation Full name or meaningDevice Manager Agent Devi

Strona 621 - XML transmission - aa...aa

2. HDLM Functions48Filtering by category:The following categories can be specified:•StartStop• Authentication• ConfigurationAccess• All of the aboveFo

Strona 622 - 8.12 KAPL13001 to KAPL14000

2. HDLM Functions49sage-ID,date-and-time,entity-affected,location-affected,audit-event-type,audit-event-result,subject-ID-for-audit-event-result,hardw

Strona 623 - KAPL13606-W

2. HDLM Functions50#: The output of this item depends on the audit event.Example of the message section for the audit event An attempt to display HDLM

Strona 624 - 8.13 KAPL15001 to KAPL16000

2. HDLM Functions512.13 Integrated HDLM management using Global Link ManagerBy using Global Link Manager, you can perform integrated path management o

Strona 625

2. HDLM Functions52Figure 2-14: Example System Configuration Using HDLM and Global Link Manager

Strona 626

2. HDLM Functions532.14 Cluster SupportHDLM can also be used in cluster configurations.For details on cluster software supported by HDLM, the supporte

Strona 628 - Component

55Chapter3. Creating an HDLM EnvironmentThis chapter describes the procedures for setting up an HDLM environment and the procedure for canceling those

Strona 629 - DLMgetras utility, see

3. Creating an HDLM Environment563.1 HDLM System RequirementsCheck the following before installing HDLM:3.1.1 Hosts and OSs Supported by HDLMYou can i

Strona 630 - DLMgetras

3. Creating an HDLM Environment57• Hitachi Universal Storage Platform 100• Hitachi Universal Storage Platform 600• Hitachi Universal Storage Platform

Strona 631

ivHP XP512 HP StorageWorks Disk Array XP512HP XP1024 HP StorageWorks XP1024 Disk ArrayHP XP10000 HP StorageWorks XP10000 Disk ArrayHP XP12000 HP Stora

Strona 632

3. Creating an HDLM Environment58• HP XP10000/HP XP12000/HP XP20000/HP XP24000• SVS(2) HBAsFor details on the applicable HBAs, see the HDLM Release No

Strona 633

3. Creating an HDLM Environment59#4You must apply MP2 or later when using the I/O fencing function. The I/O fencing function can be used only when Hit

Strona 634

3. Creating an HDLM Environment60#1When used with the Thunder 9500V series, Lightning 9900V series, Hitachi USP, Hitachi AMS2000/AMS/TMS/WMS/SMS serie

Strona 635 - Appendixes

3. Creating an HDLM Environment61SVM 1.0#4VxVM 4.1#5VxVM 5.0#5Sun Cluster 3.1#1 #5NoneSVM 1.0#6Sun Cluster 3.1 (9/04)#1 #5NoneSVM 1.0#6Sun Cluster 3.1

Strona 636 - A. Sun Cluster 3.2 Commands

3. Creating an HDLM Environment62#1In either of the following cases, the load balancing function is disabled because a reservation is issued to one of

Strona 637

3. Creating an HDLM Environment63Does not support the I/O fencing function.#3Does not support linkage with SFVS (Storage Foundation Volume Server).#4D

Strona 638

3. Creating an HDLM Environment64#11For a two-node configuration, the pathcount setting is only supported for the SCSI protocol (fencing protocol) of

Strona 639 - C. Glossary

3. Creating an HDLM Environment65(3) When Creating an Oracle RAC 10g EnvironmentRequired programsTable 3-5: Programs required to create an Oracle RAC

Strona 640 - DNum field

3. Creating an HDLM Environment66Vo l u m e M a n a g e r A S M • ASM is bundled with Oracle RAC 10g.• ASM is used as the disk memory area for files

Strona 641

3. Creating an HDLM Environment67Cluster Oracle Clusterware 10.1.0.5.0 --Volume Manager None (Specify an HDLM raw device)--Configuration 5 OS Solaris

Strona 642

vThis manual also uses the following abbreviations.UNIX A generic term for:• AIX• Solaris• Linux• HP-UXVirtual Storage Platform A generic term for:• H

Strona 643 - /dev/dsk and /dev/rdsk

3. Creating an HDLM Environment68Table 3-6: Programs required to create an Oracle RAC 10g environment (For Solaris 10)ConfigurationProgram RemarksConf

Strona 644 - /devices

3. Creating an HDLM Environment69Volume Manager ASM • ASM is bundled with Oracle RAC 10g.• ASM is used as the disk memory area for files and recovery

Strona 645

3. Creating an HDLM Environment70Cluster Sun Cluster 3.1 8/05 and Oracle Clusterware 10.2.0.2.0Volume Manager None (Specify an HDLM raw device by the

Strona 646

3. Creating an HDLM Environment71Volume Manager ASM • ASM is bundled with Oracle RAC 10g.• ASM is used as the disk memory area for files and recovery

Strona 647 - , 381, 617

3. Creating an HDLM Environment72Configuration 12OS Solaris 10 --Oracle RAC 10g Oracle 10g Database 10.2.0.3.0 Only two-node configurations are suppor

Strona 648

3. Creating an HDLM Environment73Configuration 15OS Solaris 10 --Oracle RAC 10g Oracle 10g Database 10.2.0.3.0 --Cluster Oracle Solaris Cluster 3.3 an

Strona 649

3. Creating an HDLM Environment74Configuration 18OS Solaris 10 --Oracle RAC 10g Oracle 10g Database 10.2.0.4.0 Only two-node configurations are suppor

Strona 650

3. Creating an HDLM Environment75#You must apply MP1 or later.Required patchesTable 3-7: Patches required to create an Oracle RAC 10g environment (For

Strona 651

3. Creating an HDLM Environment76#When using Oracle RAC 10g 10.2.0.1.0, apply 108993-45, not 108993-19.Table 3-8: Patches required to create an Oracle

Strona 652

3. Creating an HDLM Environment77Change the value of MISSCOUNT to the following value or greater: (number-of-paths-connected-to-the-voting-disk x 60 s

Komentarze do niniejszej Instrukcji

Brak uwag