Hp StorageWorks 1000 Modular Smart Array Instrukcja Użytkownika Strona 39

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 60
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 38
Uso de la CLI
41
HP StorageWorks Modular Smart Array 1000/1500 Interfaz de línea de comandos - Guía de usuario
Comando y respuesta de ejemplo
CLI> set auto_path_change disable
Implicit (automatic load-based) LUN ownership changes are currently
DISABLED.
CLI> set auto_path_change enable
Implicit (automatic load-based) LUN ownership changes are currently
ENABLED.
Implicit LUN ownership change preferences are as follows:
Minimum % of proxied requests to trigger implicit path change..: 75%
Minimum number of requests to LUN before path change enabled...: 65536
Minimum time to wait before changing ownership after power-up..: 30 minutes
Minimum time between ownership changes for LUN.................: 30
minutes
CLI> set auto_path_change twp=15
Implicit (automatic load-based) LUN ownership changes are currently
ENABLED.
Implicit LUN ownership change preferences are as follows:
Minimum % of proxied requests to trigger implicit path change..: 75%
Minimum number of requests to LUN before path change enabled...: 65536
Minimum time to wait before changing ownership after power-up..: 15 minutes
Minimum time between ownership changes for LUN.................: 30
minutes
Przeglądanie stron 38
1 2 ... 34 35 36 37 38 39 40 41 42 43 44 ... 59 60

Komentarze do niniejszej Instrukcji

Brak uwag