Hp StorageWorks 1510i Modular Smart Array Instrukcja Użytkownika Strona 71

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 154
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 70
migrate unit
Description Migrates an ex
isting LUN from one RAID level to another. If you attempt to
move to an unsu
pported RAID conguration for a LUN, an error message
is displayed.
NOTE:
Before changing the RAID level or stripe size of a LUN, verify there is
available, unused space on the array. Migrating from one RAID level
to another may require additional space for parity and organizational
purposes.
Syntax migrate unit <unit> raid_level=<raid level>
[stripe_size=<size>]
Operands <unit>
The number (0-31) of the LUN to modify.
raid_level=<raid level>
The RAID fault-tolerance level to use. RAID levels include:
0 = RAID 0 (no fault tolerance)
1 = RAID 1 (mirroring)
5 = RAID 5 (distributed parity)
6 = RAID 6 (Advanced Data Guarding)
NOTE:
If more than one pair of drives are included in a RAID 1 array, the
data is striped across the rsthalfofthedrivesinthearrayandthen
each drive is mirrored to a drive in the remaining half of the drives for
fault tolerance. This method is referred to as RAID 1+0.
stripe_size=<size>
[Optional]Thestripesizetoassign(inKB).Optionsinclude:
• RAID0usesstripesizes8,16,32,64,128,and256(Default:128KB)
• RAID1usesstripesizes8,16,32,64,128,and256(Default:128KB)
RAID 5 uses stripe sizes 8, 16, 32, and 64 (Default: 16 KB)
RAIDADGusesstripesizes8,16,32,and64(Default:16KB)
Example
Tomigrateunit0toRAID5withastripesizeof32KB:
CLI> migrate unit 0 raid_level=5 stripe_size=32
The RAID level of Unit 0 will now be 5.
Unit 0 is being migrated.
Use “show unit 0” to monitor progress.
See also add unit
bind unit
delete unit
1510i Modular Smart Array Command Line Interface user guide