86 HP StorageWorks MSA500 G2 Storage System User Guide
01 HP MSA500-G2 Startup Complete .........................................................................................89
02 Enable Volume <n>? '<'=NO, '>'=YES...................................................................................89
03 Critical Lock-Up Detected. Code=<n>h .................................................................................89
04 Enable Volumes ? '<'=NO, '>'=YES........................................................................................90
05 System Name: <name>............................................................................................................90
06 Restarting System....................................................................................................................91
07 Clone Firmware? '<'=NO, '>'=YES .........................................................................................91
08 Firmware Flash Failed .............................................................................................................91
20 Initializing SCSI Subsystem....................................................................................................92
21 Scanning for SCSI Devices .....................................................................................................92
22 Initializing SCSI Devices ........................................................................................................92
24 Bad SCSI Bus Mode Non-LVD Device Found.......................................................................92
30 I2C Read Failure <I2C device name> .....................................................................................93
31 I2C Write Failure <I2C device name> ....................................................................................93
32 Chassis NVRAM Contents Corrupted.....................................................................................93
40 Begin Redundancy Support .....................................................................................................94
41 Redundancy Active Active Controller.....................................................................................94
42 Redundancy Active Standby Controller ..................................................................................94
43 Redundancy Failed Hardware Failure .....................................................................................95
44 Redundancy Failed Mismatch Hardware.................................................................................96
45 Redundancy Failed Mismatch Hardware.................................................................................96
47 Redundancy Failed Cache Size Mismatch ..............................................................................97
48 Redundancy Halted Firmware Cloned.....................................................................................97
49 Redundancy Failed Firmware Lockup.....................................................................................98
50 Redundancy Failed Out of Memory ........................................................................................98
51 Redundancy Failed I/O Request Error.....................................................................................99
52 Redundancy Failed PCI Bus Error ........................................................................................100
53 Redundancy Failed No Second Controller ............................................................................100
54 Redundancy Failed Cache DIMMs Mismatch ......................................................................101
60 No Cache Module Found.......................................................................................................101
61 Dual Cache Module Size Mismatch ......................................................................................102
62 Cache Module #<n> <n>MB.................................................................................................102
63 Valid Cache Data Found at Power-Up ..................................................................................102
64 Cache Data Lost Battery Dead ..............................................................................................103
65 Cache Hardware Enabled ......................................................................................................103
66 Cache Hardware Failed and Disabled....................................................................................103
67 Cache Hardware Temporarily Disabled ................................................................................104
68 Obsolete Cache Data Deleted ................................................................................................104
69 Cache Batteries Low, Recharging .........................................................................................105
70 Cache Disabled No Configuration.........................................................................................105