Troubleshooting the Myrinet interconnect 9–15
9.24 Troubleshooting the Myrinet interconnect
This section provides some useful tips for investigating and solving potential problems with a Myrinet
interconnect. In this section, the term node is used to refer to any system that is connected to the interconnect:
a node can be a server in the HP SFS system, or a client node. The term nodeset is used to describe the
collection of nodes that are on an interconnect.
9.24.1 Start, stop, and check status
When a Myrinet interconnect is used, the associated software module on the nodes is the gm module.
To start the gm module on a node, enter the following command:
# /etc/init.d/gm start
To stop the gm module on a node, enter the following command:
# /etc/init.d/gm stop
To determine the status of the gm module on a node, enter the following command:
# /etc/init.d/gm status
To determine whether the gm module is started at boot time, enter the following command:
# chkconfig --list gm
9.24.2 Myrinet interconnect stress test
To run a stress test on the Myrinet interconnect, enter the following command:
# /opt/gm/bin/gm_stress
9.24.3 Nodeset and Node ID information
To determine the ID of a node on the Myrinet interconnect, enter the following command:
# /usr/sbin/gmlndnid -l
To determine what nodes are visible to a node on the Myrinet interconnect, enter the following command:
# /opt/gm/bin/gm_board_info
The nodeset is determined by the gm_mapper utility, and the nodeset is updated only if the gm_mapper
utility is running. You can start and stop the gm_mapper utility using the Myrinet interconnect driver. To
determine if the gm_mapper utility is running, enter the following command:
# ps auwwx | grep gm_mapper | grep -v grep
If the gm_mapper utility is not running, start it by entering the following command:
# /etc/init.d/gm start mapper
9.24.4 Disconnected link in Myrinet 2XP interconnect
If the output from the gm_board_info command does not show details of the route table for a server, this
may indicate that a link has been disconnected in the interconnect. The following example shows the output
in such a case:
[root@delta3 root]# /opt/gm/bin/gm_board_info
GM build ID is "2.1.22_Linux_rc20050811191453PDT
[email protected]:/build/nightly.jimi/builds/ia32_jimi_
HOT/output/
build/gm-2.1.22_Linux Tue Sep 27 00:53:27 IST 2005."