Przeglądanie stron 132
DescriptionItem
Displays the number of volumes for which some pages in the volume are not assigned to the tiers
specified by tiering policy level due to insufficient pool capacity. Select the Shortage point-and-
shoot filed to display the volumes whose statuses are Shortage in the Tiering Policy Group Volume
List panel.
Shortage
TIP:
When a volume is in the Shortage status, you need to take measures such as adding capacity to
the pool or moving data to other pools.
Volume Summary - TPG definition and active policy comparison
DescriptionItem
Displays the number of volumes for which the tiering policy defined for the tiering policy group
is different from the tiering policy set for the storage system. Select the Mismatch point-and-shoot
filed to display the volumeswhose statuses are Mismatch in the Tiering Policy Group Volume List
panel.
Mismatch
Pool Summary - Pool usage threshold
DescriptionItem
Displays the number of pools whose usage rate exceeds the threshold specified for Pool usage
threshold in the Edit Defaults panel. Select the Pools exceeding threshold point-and-shoot filed to
display the volumes whose usage rate exceeds the threshold in the Tiering Policy Group Pool List
panel.
Pools exceeding threshold
TIP:
When a pool is in the Pools exceeding threshold status, you need to take measures such as
adding capacity to the pool or moving data to other pools.
Related topics
Edit Defaults panel , page 116
Tiering Policy Group Pool List panel, page 128
Tiering Policy Group Volume List panel, page 133
Tiering Policy Group Volume List panel
This panel displays a list of volumes in a tiering policy group and the status of those volumes. To
display each tier's capacity information in the right-hand panel, either press the Next function key or
select the Next ---> point-and-shoot field. To return to the left-hand panel, either press the Prev function
key or select the <--- Prev point-and-shoot field.
The following figure shows the left-hand panel of the Tiering Policy Group Volume List panel: