3. Contact your HP-authorized service representative.
8.7.en.12 NONCRITICAL condition—I/O Module NVRAM read failure
The system is unable to read data from the I/O module NVRAM.
Complete the following procedure to correct this problem:
1. Record all six characters of the condition report.
2. Contact your HP-authorized service representative.
8.7.en.13 NONCRITICAL condition—I/O module removed
The system detects that an I/O module has been removed.
To correct the problem, install an I/O module.
Host conditions
The EMU has the capability of displaying host controller defined condition reports on the EMU
alphanumeric display.
The format of a host condition report is F.F.en.ec, where:
F.F. is the host element type number
en. is the two-character host element number
ec is the error code
The host controller can display host controller defined error codes on the EMU alphanumeric display