HP 4100 Enterprise Virtual Array Instrukcja Użytkownika Strona 21

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 180
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 20
8. Power supply 27. Blower 2
10. Status indicators (EMU, enclosure power, enclosure
fault)
9. I/O module A
I/O modules
Two I/O modules provide the interface between the drive enclosure and the host controllers. See
Figure 7 (page 21). They route data to and from the disk drives using Loop A and Loop B, the
dual-loop configuration. For redundancy, only dual-controller, dual-loop operation is supported.
Each controller is connected to both I/O modules in the drive enclosure.
Figure 7 I/O module
1. Status indicators (Upper port, Power, and Lower port)
2. Upper port
3. Lower port
The I/O modules are functionally identical, but are not interchangeable. Module A can only be
installed at the right end of the enclosure, and module B can only be installed at the left end of the
enclosure. See Figure 6 (page 20).
Each I/O module has two ports that can both transmit and receive data for bidirectional operation.
Activating a port requires connecting a FC cable to the port. The port function depends upon the
loop. See Figure 8 (page 21).
Figure 8 Input and output ports
2. Loop A upper port1. Loop A lower port
4. Loop B upper port3. Loop B lower port
Fibre Channel drive enclosures 21
Przeglądanie stron 20
1 2 ... 16 17 18 19 20 21 22 23 24 25 26 ... 179 180

Komentarze do niniejszej Instrukcji

Brak uwag