C H A P T E R 7 HP e-Commerce/XML Server Accelerator SA7150 User Guide
136
UTL Alarm CLI commands
To set Utilization Threshold Alarm time window:
set utl_window <seconds> (Range: 5-65000,
default: 15)
To set Utilization Threshold Alarm high-water value:
set utl_highwater <percentage> (Range: 2-
100, default: 90)
To set Utilization Threshold Alarm low-water value:
set utl_lowwater <percentage> (Range: 1-99,
default: 60)
To display current settings:
show utl_window
show utl_highwater
show utl_lowwater
Examples:
HP SA7150> set utl_window 10
HP SA7150> show utl_window
Utilization Window set [secs]: 10
HP SA7150> set utl_highwater 80
HP SA7150> show utl_highwater
Utilization High water mark [%]: 80
HP SA7150> set utl_lowwater 60
HP SA7150> show utl_lowwater
Utilization Low water mark [%]: 60