HP ProLiant BL465c Server Blade
User Guide
September 2006 (First Edition)
Part Number 418191-001
Przeglądanie stron 0
1 2 3 4 5 6 ... 86 87

Podsumowanie treści

Strona 1 - User Guide

HP ProLiant BL465c Server Blade User Guide September 2006 (First Edition) Part Number 418191-001

Strona 2 - Audience assumptions

Component identification 10 The symbols correspond to the symbols located on the interconnect bays. For more information, see the HP ProLiant

Strona 3 - Contents

Component identification 11 Local I/O cable Item Connector Description 1 Server blade For connecting to the local I/O cable connector on the se

Strona 4 - Contents 4

Operations 12 Operations In this section Power up the server blade...

Strona 5 - Contents 5

Operations 13 After initiating a virtual power down command, be sure that the server blade goes into standby mode by observing that the system power

Strona 6 - Component identification

Operations 14 Install the access panel 1. Place the access panel on top of the server blade with the hood latch open. Allow the panel to extend past

Strona 7 - Front panel LEDs

Setup 15 Setup In this section Overview ...

Strona 8 - SAS and SATA hard drive LEDs

Setup 16 Installing interconnect modules For specific steps to install interconnect modules, see the documentation that ships with the interconnect m

Strona 9 - System board components

Setup 17 Installing a server blade CAUTION: To prevent improper cooling and thermal damage, do not operate the server blade or the enclosure unles

Strona 10 - System maintenance switch

Setup 18 3. Prepare the server blade for installation. 4. Install the server blade. Completing the configuration To complete the server blade and

Strona 11 - Local I/O cable

Hardware options installation 19 Hardware options installation In this section Introduction ...

Strona 12 - Operations

© Copyright 2006 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties

Strona 13 - Remove the access panel

Hardware options installation 20 2. Prepare the hard drive. 3. Install the hard drive. 4. Determine the status of the hard drive from the hot-plu

Strona 14 - Install the access panel

Hardware options installation 21 • Handle the processor only by the edges. • Do not touch the bottom of the processor, especially the contact area

Strona 15 - Overview

Hardware options installation 22 5. Remove the processor socket protective cover. Retain the cover for future use. CAUTION: Failure to completely

Strona 16 - Connecting to the network

Hardware options installation 23 7. If the processor has separated from the installation tool, carefully re-insert the processor in the tool. 8. Al

Strona 17 - Installing a server blade

Hardware options installation 24 9. Press down firmly until the processor installation tool clicks and separates from the processor, and then remove

Strona 18 - Completing the configuration

Hardware options installation 25 11. Remove the thermal interface protective cover from the heatsink. 12. Align the tab on the processor retention

Strona 19 - Hard drive option

Hardware options installation 26 NOTE: The Advanced Memory Protection option in RBSU provides additional memory protection beyond Advanced ECC. By

Strona 20 - Processor option

Hardware options installation 27 4. Remove the air baffles. 5. Open the DIMM slot latches. 6. Install the DIMM. 7. Install the air baffles. 8.

Strona 21

Hardware options installation 28 Optional mezzanine cards enable network connectivity and provide Fibre Channel support. For mezzanine card locations

Strona 22

Hardware options installation 29 HP Smart Array E200i Battery-Backed Write Cache module option To install the component: 1. Power down the server bl

Strona 23

Contents 3 Contents Component identification...

Strona 24

Hardware options installation 30 8. Remove the Smart Array E200i cache module. 9. Install the Smart Array E200i battery pack on the new cache modul

Strona 25 - Memory options

Hardware options installation 31 10. Install the Smart Array E200i cache module. 11. Install the USB key, if necessary. 12. Install the front pane

Strona 26 - Installing DIMMs

Cabling 32 Cabling In this section Using the local I/O cable...

Strona 27 - Mezzanine card option

Cabling 33 4. Connect a USB keyboard to the second USB connector. Item Description 1 Monitor 2 USB mouse 3 USB keyboard 4 Local I/O cable Acc

Strona 28

Cabling 34 NOTE: Use a USB hub when connecting a USB diskette drive and/or USB CD-ROM drive to the server blade. The USB hub provides additional c

Strona 29

Software and configuration utilities 35 Software and configuration utilities In this section Server blade deployment tools...

Strona 30

Software and configuration utilities 36 • Remotely boot a host server blade to a virtual media image to perform a ROM upgrade or install an OS. • S

Strona 31

Software and configuration utilities 37 • Ethernet NIC with 10/100 RJ-45 connector • TCP/IP networking and an IP address compatible with one of the

Strona 32 - Cabling

Software and configuration utilities 38 Deployment methods Three primary deployment methods are supported: IMPORTANT: To deploy a server blade wi

Strona 33

Software and configuration utilities 39 CD-ROM deployment CD-ROM deployment involves using a bootable CD that executes scripts to configure the hard

Strona 34

Contents 4 Configuration tools...

Strona 35 - In this section

Software and configuration utilities 40 Diskette image deployment To deploy with a diskette image, the user creates a DOS-based network-enabled boot

Strona 36 - Network-based PXE deployment

Software and configuration utilities 41 Configuration tools SmartStart software SmartStart is a collection of software that optimizes single-server

Strona 37

Software and configuration utilities 42 IMPORTANT: RBSU automatically saves settings when you press the Enter key. The utility does not prompt yo

Strona 38 - Deployment methods

Software and configuration utilities 43 • Suggests the optimum configuration for an unconfigured system • Provides different operating modes, enabl

Strona 39 - CD-ROM deployment

Software and configuration utilities 44 10. Press the F10 key to confirm exiting RBSU. The server will automatically reboot. Option ROM Configurati

Strona 40 - Diskette image deployment

Software and configuration utilities 45 • Remotely power up, power down, or reboot the host server. • Send alerts from iLO 2 regardless of the stat

Strona 41 - Configuration tools

Software and configuration utilities 46 HP ProLiant Essentials Virtualization Management Software The ProLiant Essentials Virtual Machine Management

Strona 42 - Array Configuration Utility

Software and configuration utilities 47 Safety and security benefits When you flash the system ROM, ROMPaq writes over the backup ROM and saves the

Strona 43 - SAN configuration

Software and configuration utilities 48 Survey Utility Survey Utility, a feature within HP Insight Diagnostics (on page 47), gathers critical hardwa

Strona 44 - Management tools

Software and configuration utilities 49 For installation information, refer to the HP ISEE Client Installation and Upgrade Guide (ftp://ftp.hp.com/p

Strona 45 - Management Agents

Contents 5 POST error messages and beep codes...

Strona 46 - Redundant ROM support

Software and configuration utilities 50 Operating system version support Refer to the operating system support matrix (http://www.hp.com/go/supporto

Strona 47 - Diagnostic tools

Troubleshooting 51 Troubleshooting In this section Troubleshooting resources ...

Strona 48 - Array Diagnostic Utility

Troubleshooting 52 Important safety information Familiarize yourself with the safety information in the following sections before troubleshooting the

Strona 49 - Keeping the system current

Troubleshooting 53 subassembly/module-level repair. Because of the complexity of the individual boards and subassemblies, no one should attempt to ma

Strona 50 - Care Pack

Troubleshooting 54 NOTE: To verify the server configuration, connect to the System Management homepage and select Version Control Agent. The VCA g

Strona 51 - Troubleshooting

Troubleshooting 55 Start diagnosis flowchart Use the following flowchart to start the diagnostic process. Item Refer to 1 "General diagnos

Strona 52 - Important safety information

Troubleshooting 56 General diagnosis flowchart The General diagnosis flowchart provides a generic approach to troubleshooting. If you are unsure of

Strona 53 - Symptom information

Troubleshooting 57 Server blade power-on problems flowchart Symptoms: • The server does not power on. • The system power LED is off or amber. •

Strona 54 - Troubleshooting flowcharts

Troubleshooting 58 NOTE: For the location of server LEDs and information on their statuses, refer to the server documentation. Possible causes: •

Strona 55 - Start diagnosis flowchart

Troubleshooting 59 POST problems flowchart Symptoms: • Server does not complete POST NOTE: The server has completed POST when the system attempts

Strona 56 - General diagnosis flowchart

Component identification 6 Component identification In this section Front panel components ...

Strona 57 - Symptoms:

Troubleshooting 60 OS boot problems flowchart There are two ways to use SmartStart when diagnosing OS boot problems on a server blade: • Use iLO

Strona 58

Troubleshooting 61 Possible causes: • Corrupted OS • Hard drive subsystem problem • Incorrect boot order setting in RBSU Item See 1 HP ROM-Bas

Strona 59 - POST problems flowchart

Troubleshooting 62 * See the server blade OS boot problems flowchart (on page 60) Server fault indications flowchart Symptoms: • Server boots, but

Strona 60 - OS boot problems flowchart

Troubleshooting 63 Possible causes: • Improperly seated or faulty internal or external component • Unsupported component installed • Redundancy fa

Strona 61

Troubleshooting 64 POST error messages and beep codes Introduction to POST error messages The error messages and codes in this section include all

Strona 62 - Troubleshooting 62

Troubleshooting 65 For a complete listing of error messages, refer to the "POST error messages" in the HP ProLiant Servers Troubleshooting

Strona 63 - Redundancy failure

Battery replacement 66 Battery replacement If the server blade no longer automatically displays the correct date and time, you may need to replace t

Strona 64 - Troubleshooting 64

Regulatory compliance notices 67 Regulatory compliance notices In this section Regulatory compliance identification numbers ...

Strona 65 - Troubleshooting 65

Regulatory compliance notices 68 Class A equipment This equipment has been tested and found to comply with the limits for a Class A digital device,

Strona 66 - Battery replacement

Regulatory compliance notices 69 Modifications The FCC requires the user to be notified that any changes or modifications made to this device that a

Strona 67 - FCC rating label

Component identification 7 Front panel LEDs Item Description Status 1 UID LED Blue = Identified Blue flashing = Active remote management Off

Strona 68 - FCC logo, United States only

Regulatory compliance notices 70 Disposal of waste equipment by users in private households in the European Union This symbol on the product or on

Strona 69 - Modifications

Regulatory compliance notices 71 Korean notice Class A equipment Class B equipment Laser compliance This product may be provided with an optical

Strona 70 - BSMI notice

Regulatory compliance notices 72 • Do not attempt to recharge the battery. • Do not expose the battery to temperatures higher than 60°C (140°F).

Strona 71 - Battery replacement notice

Electrostatic discharge 73 Electrostatic discharge In this section Preventing electrostatic discharge...

Strona 72

Specifications 74 Specifications In this section Environmental specifications ...

Strona 73 - Electrostatic discharge

Technical support 75 Technical support In this section Before you contact HP...

Strona 74 - Specifications

Technical support 76 • Mandatory—Parts for which customer self repair is mandatory. If you request HP to replace these parts, you will be charged fo

Strona 75 - Technical support

Technical support 77 Pour plus d'informations sur le programme CSR de HP, contactez votre Mainteneur Agrée local. Pour plus d'informations

Strona 76

Technical support 78 CSR-Teile werden abhängig von der Verfügbarkeit und vom Lieferziel am folgenden Geschäftstag geliefert. Für bestimmte Standorte

Strona 77 - Customer Self Repair

Technical support 79 Customer Self Repair Veel onderdelen in HP producten zijn door de klant zelf te repareren, waardoor de reparatieduur tot een mi

Strona 78 - Technical support 78

Component identification 8 SAS and SATA hard drive LEDs Item Description 1 Fault/UID LED (amber/blue) 2 Online LED (green) SAS and SATA h

Strona 79 - Reparo feito pelo cliente

Technical support 80 Conforme a disponibilidade e o local geográfico, as peças CSR serão enviadas no primeiro dia útil após o pedido. Onde as condiç

Strona 82 - Technical support 82

Acronyms and abbreviations 83 Acronyms and abbreviations ABEND abnormal end ACU Array Configuration Utility ADU Array Diagnostics Utility AMP Adv

Strona 83 - Acronyms and abbreviations

Acronyms and abbreviations 84 IML Integrated Management Log NBP Network Bootstrap Program ORCA Option ROM Configuration for Arrays PCIe periphera

Strona 84

Index 85 A access panel 13, 14 ACU (Array Configuration Utility) 42 ADU (Array Diagnostic Utility) 48 ASR (Automatic Server Recovery) 44, 83

Strona 85 - Index 85

Index 86 installation, server options 19 installing hardware 19 Integrated Management Log (IML) 48 internal USB connector 47 J Japanese notic

Strona 86 - Index 86

Index 87 System Erase Utility 45 system maintenance switch 10 Systems Insight Manager 45 T Taiwan battery recycling notice 72 technical suppo

Strona 87 - Index 87

Component identification 9 Online/activity LED (green) Fault/UID LED (amber/blue) Interpretation Off Steadily amber A critical fault condition has b

Komentarze do niniejszej Instrukcji

Brak uwag