Hp ProLiant XL220a Gen8 v2-Server Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Sprzęt komputerowy Hp ProLiant XL220a Gen8 v2-Server. HP ProLiant XL220a Gen8 v2-Server User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 0
HP ProLiant XL220a Gen8 v2 Server
User Guide
Abstract
This document is for the person who installs, administers, and troubleshoots servers and storage systems. HP assumes you are qualified in the
servicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels.
Part Number: 752048-001
June 2014
Edition: 1
Przeglądanie stron 0
1 2 3 4 5 6 ... 73 74

Podsumowanie treści

Strona 1 - User Guide

HP ProLiant XL220a Gen8 v2 Server User Guide Abstract This document is for the person who installs, administers, and troubleshoots servers and stora

Strona 2

Component identification 10 Drive numbering Item Description 1 Drive bay 2 (node 1) 2 Drive bay 1 (node 1) 3 Drive bay 1 (node 2) 4 Drive bay 2

Strona 3 - Contents

Component identification 11 Item LED Status Definition 1 Locate Solid blue The drive is being identified by a host application. Flashin

Strona 4 - Contents 4

Operations 12 Operations Power down the server Before powering down the server for any upgrade or maintenance procedures, perform a backup of critic

Strona 5 - Contents 5

Operations 13 Remove the drive 1. Determine the status of the drive from the drive LED definitions ("Hot-plug drive LED definitions" on p

Strona 6 - Component identification

Operations 14 Remove the processor air baffle 1. Power down the server (on page 12). 2. Disconnect all peripheral cables from the server. 3. Remo

Strona 7 - Front panel LEDs and buttons

Operations 15 6. Remove the PCI riser board assembly. A T-10 screwdriver (for horizontal screws) and a T-15 screwdriver (for vertical screws) are re

Strona 8 - System board components

Operations 16 8. Disconnect the front panel LED board assembly cables. 9. Remove all drives ("Remove the drive" on page 13). 10. Remove

Strona 9 - System maintenance switch

Operations 17 Install the processor air baffle 1. Install the processor air baffle. IMPORTANT: If the DIMM latches are not fully closed, the b

Strona 10 - Drive numbering

Operations 18 2. Install the PCI riser board assembly. 3. Connect all cables to existing expansion boards. 4. Install the server (on page 18). 5

Strona 11

Operations 19 To install the component: 1. Prepare the server for installation. 2. Install the server. When seated properly, the server will be f

Strona 12 - Operations

© Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties

Strona 13 - Remove the server

Setup 20 Setup Setup overview Installation of a server requires the following steps: 1. Install and configure a chassis. 2. Install any server opt

Strona 14

Setup 21 CAUTION: To prevent improper cooling and thermal damage, do not operate the chassis unless all bays are populated with a component or a b

Strona 15

Setup 22 Installing the operating system To operate properly, the server must have a supported operating system installed. For the latest informatio

Strona 16 - Operations 16

Hardware options installation 23 Hardware options installation Introduction If more than one option is being installed, read the installation instru

Strona 17

Hardware options installation 24 c. Remove the heatsink from the processor backplate. WARNING: To reduce the risk of personal injury from hot s

Strona 18 - Install the server

Hardware options installation 25 CAUTION: THE PINS ON THE SYSTEM BOARD ARE VERY FRAGILE AND EASILY DAMAGED. To avoid damage to the system board: •

Strona 19 - Operations 19

Hardware options installation 26 4. Apply all the grease to the top of the processor in the following pattern to ensure even distribution. 5. Inst

Strona 20

Hardware options installation 27 Memory subsystem architecture The memory subsystem in this server is divided into channels. The processor supports

Strona 21 - Powering up the chassis

Hardware options installation 28 Item Description Definition 1 Size — 2 Rank 1R = Single-rank 2R = Dual-rank 3R = Three-rank 4R = Quad-rank

Strona 22 - Registering the server

Hardware options installation 29 CAUTION: To avoid damage to the drives, memory, and other system components, the air baffle, and drive blanks mus

Strona 23 - Processor option

Contents 3 Contents Component identification ...

Strona 24

Hardware options installation 30 Drive guidelines When adding drives to the server, observe the following general guidelines: • The system automat

Strona 25

Hardware options installation 31 Controller options The server supports installation of controller options in the PCI riser assembly for node 1 and

Strona 26 - Memory options

Hardware options installation 32 FBWC cache module and capacitor pack option To install the component: 1. Power down the server (on page 12). 2. D

Strona 27 - DIMM identification

Hardware options installation 33 9. Install the FBWC capacitor pack into the holder mounted in the server. 10. Route the capacitor pack cables as

Strona 28 - Installing a DIMM

Hardware options installation 34 o Node 2 11. Connect and route all drive cables. For more information, see "Drive cabling (on page 52)."

Strona 29

Hardware options installation 35 • When installing or replacing hardware, HP service providers cannot enable the TPM or the encryption technology.

Strona 30 - Installing a hot-plug drive

Hardware options installation 36 8. Install the TPM security rivet by pressing the rivet firmly into the system board. 9. Install the PCI riser bo

Strona 31 - Controller options

Hardware options installation 37 8. Enable the TPM in the OS. For OS-specific instructions, see the OS documentation. CAUTION: When a TPM is ins

Strona 32

Software and configuration utilities 38 Software and configuration utilities Server mode The software and configuration utilities presented in this

Strona 33

Software and configuration utilities 39 iLO 4 enables and manages the Active Health System (on page 39) and also features Agentless Management. All

Strona 34

Contents 4 HP Trusted Platform Module option ...

Strona 35

Software and configuration utilities 40 The data that is collected is managed according to the HP Data Privacy policy. For more information see the

Strona 36

Software and configuration utilities 41 HP Insight Diagnostics Offline Edition performs various in-depth system and component testing while the OS i

Strona 37

Software and configuration utilities 42 HP Insight Remote Support is available as part of HP Warranty, HP Care Pack Service, or HP contractual suppo

Strona 38 - HP iLO Management

Software and configuration utilities 43 ProLiant BL, ML, DL, and SL servers. The toolkit includes a modular set of utilities and important documenta

Strona 39 - Active Health System

Software and configuration utilities 44 • Language selection For more information on RBSU, see the HP ROM-Based Setup Utility User Guide on the HP

Strona 40 - Intelligent Provisioning

Software and configuration utilities 45 Boot options Near the end of the boot process, the boot options screen is displayed. This screen is visible

Strona 41 - Erase Utility

Software and configuration utilities 46 Utilities and features Array Configuration Utility ACU is a utility with the following features: • Runs as

Strona 42 - HP Insight Online

Software and configuration utilities 47 HP Smart Storage Administrator HP SSA is a configuration and management tool for HP Smart Array controllers.

Strona 43 - HP ROM-Based Setup Utility

Software and configuration utilities 48 For more information, go to the HP website (http://www.hp.com/go/hpsc) and click on Drivers, Software &

Strona 44 - Auto-configuration process

Software and configuration utilities 49 Keeping the system current Drivers IMPORTANT: Always perform a backup before installing or updating devi

Strona 45 - Configuring AMP modes

Contents 5 Electrostatic discharge ...

Strona 46 - Utilities and features

Software and configuration utilities 50 HP operating systems and virtualization software support for ProLiant servers For information about specific

Strona 47 - ROMPaq utility

Troubleshooting 51 Troubleshooting Troubleshooting resources The HP ProLiant Gen8 Troubleshooting Guide, Volume I: Troubleshooting provides procedur

Strona 48 - Redundant ROM support

Cabling 52 Cabling Internal server cabling This section provides guidelines that help you make informed decisions about cabling the server and hardw

Strona 49 - Keeping the system current

Cabling 53 Front panel LED board assembly cabling FBWC capacitor pack cabling SUV cable connectors CAUTION: Before disconnecting the SUV cab

Strona 50 - ProLiant servers

Cabling 54 Item Connector Description 1 Serial For trained personnel to connect a null modem serial cable and perform advanced diagnostic p

Strona 51 - Troubleshooting

Regulatory information 55 Regulatory information Safety and regulatory compliance For safety, environmental, and regulatory information, see Safety

Strona 52 - Cabling

Regulatory information 56 Valid date formats include the following: • YWW, where Y indicates the year counting from within each new decade, with 20

Strona 53 - SUV cable connectors

Electrostatic discharge 57 Electrostatic discharge Preventing electrostatic discharge To prevent damaging the system, be aware of the precautions yo

Strona 54 - Item Connector Description

Specifications 58 Specifications Environmental specifications Specification Value Temperature range* — Operating 10°C to 35°C (50°F to 95°F) Shi

Strona 55 - Regulatory information

Support and other resources 59 Support and other resources Before you contact HP Be sure to have the following information available before you call

Strona 56 - Warranty information

Component identification 6 Component identification Front panel components Item Description 1 Drive bay 2 (node 1) 2 Drive bay 1 (node 1) 3 SUV c

Strona 57 - Electrostatic discharge

Support and other resources 60 providers or service partners) identifies that the repair can be accomplished by the use of a CSR part, HP will ship

Strona 58 - Specifications

Support and other resources 61 Pour plus d'informations sur le programme CSR de HP, contactez votre Mainteneur Agrée local. Pour plus d'in

Strona 59 - Support and other resources

Support and other resources 62 HINWEIS: Einige Teile sind nicht für Customer Self Repair ausgelegt. Um den Garantieanspruch des Kunden zu erfüllen,

Strona 60

Support and other resources 63 sustituciones que lleve a cabo el cliente, HP se hará cargo de todos los gastos de envío y devolución de componentes

Strona 61 - Customer Self Repair

Support and other resources 64 Opcional – Peças cujo reparo feito pelo cliente é opcional. Essas peças também são projetadas para o reparo feito pel

Strona 62

Support and other resources 65

Strona 63 - Reparo feito pelo cliente

Support and other resources 66

Strona 64

Acronyms and abbreviations 67 Acronyms and abbreviations ABEND abnormal end ACU Array Configuration Utility ADM Advanced Data Mirroring AMP Advan

Strona 65

Acronyms and abbreviations 68 HP SIM HP Systems Insight Manager HP SSA HP Smart Storage Administrator HP SUM HP Smart Update Manager iLO Integrat

Strona 66

Acronyms and abbreviations 69 RBSU ROM-Based Setup Utility RDIMM registered dual in-line memory module RDP Rapid Deployment Pack RoHS Restriction

Strona 67 - Acronyms and abbreviations

Component identification 7 Front panel LEDs and buttons Item Description Status 1 NIC 1 LED (node 1) Solid green = Link to network Flashing gr

Strona 68

Acronyms and abbreviations 70 UDIMM unregistered dual in-line memory module UID unit identification VCA Version Control Agent VCRM Version Contro

Strona 69

Documentation feedback 71 Documentation feedback HP is committed to providing documentation that meets your needs. To help us improve the documentat

Strona 70 - Version Control Agent

Index 72 A ACU (Array Configuration Utility) 38, 46, 47 air baffle, installation 17 air baffle, removal 14 Array Configuration Utility (ACU)

Strona 71 - Documentation feedback

Index 73 installing I/O modules 20 installing operating system 22 installing the processor air baffle 17 Integrated Lights-Out (iLO) 38, 40

Strona 72 - Index 72

Index 74 W website, HP 59

Strona 73 - Index 73

Component identification 8 Item Description Status 6 Power On/Standby button and system power LED (node 2) Solid green = System on Flashing green

Strona 74 - Index 74

Component identification 9 Item Description 16 PCIe riser board connector (node 2) 17 System maintenance switch (node 2) 18 Drive backplane power c

Powiązane modele: Apollo 6000 Chassis

Komentarze do niniejszej Instrukcji

Brak uwag