HP A8800 Routers Installation Guide Part number: 5998-1416 Document version: 6W104-20130912
Installing the router Figure 1 shows the steps for installing the router. Figure 1 Installation flowchart Installation prerequisites Before installi
95 (5) Overload automatic protector The protector automatically opens the electric circuit when the current exceeds the threshold and closes the elect
Engineering labels Engineering labels are used to identify cables and devices for easy maintenance after installation. There are two types of engine
Figure 61 Label for power cables 12TO: (1) Cable tie (2) Dividing line on the label Generic labels A generic label is bar-shaped with fixed dimensi
Figure 62 Generic label (1) Dividing line on the label (2) Cut dotted line Labels for devices A device label is used to identify the device name, m
Figure 63 Affixing a label Figure 64 shows the affixed labels when the cable is laid vertically and horizontally. Figure 64 Affixed labels TO:B02 0
Figure 65 Affixing a label TO:B03–48V2 Bind cable ties on both ends of a cable. After the bundling, the finished identification plate should be on t
Figure 67 Affixing a generic label Affixing a label to a device Remove the device label and stick it to the device. You can stick a device label to
Content MeaningExampleB—Chassis number Numbered in top-down order with two digits, for example, 01. C—Slot number Numbered in top-down and left-right
Engineering labels for optical fibers These labels are affixed to optical fibers that connect the fiber ports on the cards in a chassis, or connect f
Content Meaning ExampleB—Chassis number Numbered in bottom-up order with two digits, for example, 01. C—Slot number Numbered in top-down and left-ri
• There is no debris inside or around the rack. • The router can be installed only in a 4-post 19-inch standard rack. Mounting slide rails to the r
• A01-01-05-05-R—The peer end of the optical fiber is connected to Optical Receiving Interface 5 on Slot 05, Chassis 01 in the cabinet on Row A, Col
PGND and RTN are two copper bars, on which the terminal blocks are short-circuited, so which terminal is connected makes no difference. You only need
107 You can fill in the device name, model, IP address, serial number, installation address, and installation date on a device label. Figure 73 Examp
Cable management Label cables before you route or bundle them. For more information about labeling cables, see " Engineering labels for cables.&
Figure 75 Binding the cables • When you route cables through sharp sheet metal penetration points or along sharp edges of mechanical parts, use bu
NOTE: The devices in the following figures are for illustration only. Figure 77 Network cable management 110
111 Figure 78 Optical fiber management Use strapping tapes to carefully bind optical fibers. Avoid excessive force. For more information, see the i
Support and other resources Contacting HP For worldwide technical support information, see the HP support website: http://www.hp.com/support Before c
• HP Education http://www.hp.com/learn Conventions This section describes the conventions used in this documentation set. Command conventions Conven
114 Network topology icons Represents a generic network device, such as a router, switch, or firewall. Represents a routing-capable device, such as
NOTE: The appearance and installation methods of slide rails depend on the slide rail types. Installing cage nuts to the rack Before mounting the c
Index A C D E F G I L M O P R S T V A Affixing labels,98 C Cable management examples,109 Cable management guidelines,108 Cable routing recommendatio
S Safety recommendations,1 SPC card LEDs,86 Subcard LEDs,88 T Technical specifications,61 Technical support,47 V Verifying and diagnosing transceive
To install a cable management bracket: 1. Attach the cable management bracket to the chassis, and align the screw holes on the cable management brack
Figure 5 Installing the cable management bracket on the A8805/A8812 Installing the mounting brackets Before installing the router to the rack, insta
Installing an impedance carrier (optional) An impedance carrier is shipped with the A8808 only. You can install the impedance carrier at the rear of t
that the bottom edge of the slide rail aligns with the middle of the narrowest metal area between holes, and that the cage nuts are installed in the c
3. Insert the grounding screw into the grounding hole and tighten the screw. 4. Connect the other end of the grounding cable to the grounding strip
Installing a DC power supply 1. Remove the air filter frame of the power supply and gently pull the DC power supply handle out. 2. Holding the handl
Installing an NEPS1800-A AC power supply 1. Pull the handle of the power supply downward to the unlock position. 2. Gently push the power supply in
Legal and notice information © Copyright 2011-2013 Hewlett-Packard Development Company, L.P. No part of this documentation may be reproduced or transm
Figure 13 Removing the protection cover 2. Move the ejector levers of the card outward. Supporting the bottom of the card with both hands, slowly p
3. Remove the blank panel (if any) from the slot to be used on the SPE card. 4. Unpack the subcard. To install a subcard: 1. Turn the ejector lever
Connecting an AC power cable CAUTION: NEPS3500-A requires a 16 A power cable (AC), so you must use a 16 A busbar and make sure the AC power source
WARNING! To protect operators from being shocked, install the protection cover over the DC terminal block immediately after you connect the power cab
Verifying the installation WARNING! Before verifying the installation, make sure you have turned off the power to avoid bodily injury and router da
Connecting the router to the network Logging in to the router The most common way to log in to a router is through the console port. It is also the pr
Figure 19 Connecting the router and the PC through the console port To connect the console cable: 1. Connect the DB-9 connector of the console cabl
Figure 20 Connection Description dialog box for HyperTerminal 2. Enter the name of the new connection in the Name box, and then click OK. The syst
Figure 21 Selecting a port for the HyperTerminal connection 3. Select a port from the Connect using list, and then click OK. 4. Set the Bits per se
Figure 22 Setting the serial port parameters 24
Contents Preparing for installation ··················································································································
Figure 23 HyperTerminal window 5. Select File > Properties in the HyperTerminal window. 6. On the Settings tab, select VT100 for terminal emul
Figure 24 Setting the terminal emulation parameters Powering on the router CAUTION: Before powering on the router, locate the power switch in the
2. Turn on the power switch on the router. Before the router is powered on, the following information is displayed: DDR2 SDRAM test successful. Syste
kbd->bi_immr_base = 0xff700000. Starting kernel at 0x10000 ...
Connecting through an AUX cable You need an AUX cable when configuring a router using a remote dial-up modem. An AUX cable is an 8-core shielded cable
Installing a transceiver module CAUTION: During installation, do not touch the golden finger of the SFP module. The installation procedures for an X
Figure 27 Connecting an optical fiber to an SFP module Installing an FMT (optional) The FMT is installed in a cabinet for winding redundant fibers b
CAUTION: Do not bind cables at the air exhaust vent to prevent the cables from aging too fast. For more information, see "Cable management."
Hardware management This chapter describes the hardware management functions of the router. Displaying electrical label data Electrical label data
6 NONE Absent NONE Table 10 Command output Field Description Slot No. Slot number of a card. Brd Type Hardware type of a ca
Displaying the operating state of a fan ··············································································································
Step Command Remarks 1. Reboot a card, or the whole system immediately. reboot [ slot slot-number ] Optional. Available in user view. The precision o
Configuring temperature alarm thresholds for a card Use the following command to set temperature alarm thresholds for a card. When the temperature of
The in-service hardware failure diagnosis includes the detection for chips, cards, and the forwarding service, and automatic fix actions taken for the
Field DescriptionInfo Detailed alarm information. Slot n board state is faulty. Card n is faulty. The reason may be the card is booting or the card f
Digital Diagnostic Monitoring : YES Vendor Name : HP Ordering Name : JD118B Table 15 Command output Field Desc
Diagnosing transceiver modules The device provides the alarm function and digital diagnosis function for transceiver modules. When a transceiver modul
Field RemarksXFP RX loss of signal RX signal is lost. RX not ready RX is not ready. RX CDR loss of lock RX clock cannot be recovered. TX fault TX
42 Table 18 Command output Field DescriptionTransceiver diagnostic information Fault detection information of the transceiver module plugged in the in
Troubleshooting This chapter describes how to troubleshoot router installation failures. The router power supply system, fans, and cards have multipl
Table 19 AC power supply LED LED Status Description Input Steady green Power is being input correctly. Off The power supply is absent or has input v
v Transceiver modules ································································································································
Table 21 Fan LEDs LED Status Description RUN Off The fan tray has failed. Steady green The fan tray is operating properly. ALM Off The fan tray is
2. Press the MPU RESET button to reset the MPU, and then verify that the corresponding RUN LED is on. 3. Make sure the MPU is seated properly. You
47 6. If the LED is for a copper or fiber combo port, make sure the port has been activated. If not, use the combo enable { copper | fiber } command
Replacement procedures This chapter provides information about replacing components on the router. Replacing a power supply system WARNING! • Power
Figure 30 Replacing a DC power supply (A) DC power supply to be removed (B) DC power supply to be installed Replacing an AC power supply 1. Pull th
5. Slowly push a new power frame into the slot along the slide rails until the rear of the power frame has close contact with the backplane. 6. Use
Cleaning a power supply air filter To ensure proper ventilation of the power supply, HP recommends that you clear the air filter monthly. The NEPS350
2. Remove the blank panel (if any) from the slot to be used. Keep the removed blank panel and protection cover for future use. 3. Unpack the card to
Figure 35 Replacing a card Replacing a subcard CAUTION: When the router is operating, you must remove the SPE card before removing or installing t
Figure 36 Replacing a subcard (A) Subcard to be removed (B) Subcard to be installed Replacing a fan tray CAUTION: Fan trays are hot-swappable. If
Preparing for installation Overview This series is a line of data center routers. You can deploy the A8800 routers at the core layer and distribution
3. Gently insert the new fan tray into the fan tray slot along the slide rails until it has close contact with the backplane. 4. Use a Phillips scr
Figure 38 Replacing a fan tray for an A8808 (A) Fan tray to be removed (B) Fan tray to be installed Replacing a chassis air filter CAUTION: Clean
Figure 39 Replacing chassis air filters for an A8808 Replacing an air filter for an A8805/A8812 1. Loosen the captive screws on the air filter, as
Figure 41 CF card slot (1) CF card cover (2) CF card eject button (3) CF card (4) CF card LED The CF card is installed on the MPU of the router. If
Figure 42 Replacing a CF card Replacing a transceiver module CAUTION: When installing or removing an SFP transceiver module, do not touch the gold
Figure 43 Removing an SFP transceiver module Figure 44 Installing an SFP transceiver module 60
Hardware specifications Environmental requirements Table 22 Environment requirements Temperature RangeOperating temperature Long term: 0°C to 45°C (32
Figure 45 A8805 front view (1) ESD-preventive wrist strap port (2) MPU slots (slots 0 and 1) (3) LPU slots (slots 2 to 6)(4) Power supply slots (5
Figure 46 A8805 rear view (1) Rear cover handle (2) Grounding screw (3) Fan tray A8808 chassis views You can install one or two power supplies, b
Figure 47 A8808 front view (1) Fan tray (2) MPU slots (slots 4 and 5) (3) LPU slots (slots 0 to 3, 6 to 9) (4) Cable management bracket (5) Power
Installation site requirements The following tables provide information about temperature and humidity, cleanness, and air quality requirements. CAU
Figure 48 A8808 rear view (1) Air filter (2) Grounding screw (3) Rear cover handle 65
A8812 chassis views You can install one or two power supplies, but intermixing of AC and DC power supplies is not allowed. In this figure, four AC pow
Figure 50 A8812 rear view (1) Rear cover handle (2) Grounding screw (3) Fan tray 67
Chassis specifications Table 23 Chassis specifications Model Max power consumption Weight Dimensions (H × W × D) Height (RU)A8805 2040 W (AC) 1795 W
Figure 51 Fan trays (1) RUN LED (2) ALM LED Table 24 Fan LEDs LED Status Description RUN Off The fan tray has failed. Steady green The fan
Figure 52 A8805 airflow (1) Chassis air intake (2) Chassis air outlet (3) Power supply air intake (4) Power supply air outlet A8808 airflow The c
Figure 53 A8808 airflow (1) Chassis air intake (2) Chassis air outlet (3) Power supply air intake (4) Power supply air outlet If you have install
Card model Power consumption Net weight Dimensions (H × W × D) SPC-GP48L 67 W to 115 W 3.50 kg (7.72 lb)40 × 400 × 380 mm (1.57 × 15.75 × 14.96 in)
Card model Power consumption Net weight Dimensions (H × W × D) PIC-CL2G8L 18.22 W to 33 W 0.65 kg (1.43 lb) 37 × 165 × 142 mm (1.46 × 6.50 × 5.59 i
Item SR02SRP1F3 SR02SRP2F3 Ports • 1 console port • 1 AUX port • 1 network management port • 1 RS-232/485 port (reversed for future use) • 1 CF c
Rack-mounting requirements Before rack-mounting a router, make sure the rack meets the following requirements: • HP recommends that the router is mo
Subcard specifications Table 30 Subcard specifications Model Interface type and number Available transceiver modules and cablesPIC-GP10L 10-port 100
Model Interface type and number Available transceiver modules and cablesPIC-CL1G8L 1-port OC-3/STM-1 channelized to E1/T1 CPOS optical interface (SFP
Model Interfaces Supported interface modulesIM-LB • One console port • Two USB ports (reserved) • Two 10/100/1000 BASE-T copper ports • Two GE com
Table 33 AC power supply LEDsLED Status Description Input (IN) Steady green The input voltage is in the normal range. Off The power supply or power s
Figure 56 NEPS3500-D DC power supply (1) Power input LED (2) Power output LED (3) Power fault LED Table 34 DC power supply LEDs LED Status Descrip
• Make sure the maximum total output power of the power supplies exceeds the system power consumption. (HP recommends reserving a certain power de-ra
No. Specifications 2 Connector type Code (Length) Countries or regions where the type of power cables conforms to local safety regulations and
No. Specifications 4 Connector type Code (Length) Countries or regions where the type of power cables conforms to local safety regulations and c
83 No. Specifications I type 0404A01A (3 m or 9.8 ft)Australia Connector outline Power cable outline Connector outline 7 Connector type Cod
LEDs In this document, SPC cards refer to the interface cards prefixed with SPC, for example, SPC-GP48L, and SPE cards refer to the base cards prefix
4 The rack accessories and installation tools are not described in this section. The accessories and installation tools may vary depending on the rack
MPU LEDs Figure 57 MPU LEDs (1) CF card status LED (CFS) (2) Network management port LED (ACT) (3) Network management port LED (LINK)(4) MPU status L
LED Status DescriptionFlashing yellow Data is being transmitted and/or received. LPU status LEDs Table 43 LPU status LEDs LED Status Description R
LINK/ACT LED Table 45 describes the LINK/ACT LED for the interfaces on the SPC-GP48L card and the GE fiber interfaces numbered from 1 to 16 on the SPC
88 SPE card LED The LED for all SPE cards is the same. Table 48 SPE card LED LED Status Description RUN Steady green The card is faulty or is start
Transceiver modules CAUTION: If you connect a long-haul (at least 40 km, or 24.86 miles) transceiver module to a short optical fiber (see Figure 58)
NOTE: Multi-mode optical fibers are described using a system of classification determined by the ISO 11801 standard—OM1, OM2, and OM3—which is based
Product code Description Central wavelength Connector Fiber Max. transmission distanceJD115A HP X170 1G SFP LC LH70 1510 Transceiver 1510 nm LC 9/125
OC-48/STM-16 SFP transceiver modules Table 52 OC-48/STM-16 SFP transceiver modules Product code Description Central wavelengthConnector Fiber Max. tra
93 Product code Description Central wavelength Connector Fiber Max transmission distanceJD120B HP X110 100M SFP LC LX Transceiver 1310 nm LC 9/125 μm
Lightning protection Connecting the AC power supply to a power strip with lightning protection If part of the AC power line is routed outdoors, use a