Instruc tions
hp StorageWorks Enterprise
Virtual Array Updating
Product Soft ware
VCS Product Version: 3.020 Command View EVA Version:3.2
Sixth Edition
(July 2004)
Part Number:AA-RS29F-TE
This document contains the necessary procedures to update the product software for the HP StorageWorks
Enterprise Virtual Array. This document outlines the proper upgrade process and includes detailed installation
instructions for Enterprise Virtual Array product software, such as HP OpenView Storage Management Appliance
software, HP Storage Works Command View EVA, and HP Storage W orks Virtual Controller Software. For the latest
version of these Instructions and other Enterprise Virtual Array documentation, access the HP stor age website at
http://h18006.www1.hp.com/products/storageworks/enterprise/documentation.html
Przeglądanie stron 0
1 2 3 4 5 6 ... 140 141

Podsumowanie treści

Strona 1 - Product Soft ware

Instruc tionshp StorageWorks EnterpriseVirtual Array UpdatingProduct Soft wareVCS Product Version: 3.020 Command View EVA Version:3.2Sixth Edition(Jul

Strona 2

About this GuideConventionsConventions consist of the following:• Document conventions• Text symbols• Equipment symbolsDocument conventionsThe documen

Strona 4

Chapter 4.Downgrading the Enterprise VirtualArrayThis chapter contains the information about downgrading the product software on yourstoragesystem to

Strona 5 - List of Figures

Chapter 4. Downgrading the Enterprise Virtual Array4.Click Code load.A confirmation message displays.5.Click OK.The Code Load Storage System page disp

Strona 6

Chapter 4. Downgrading the Enterprise Virtual ArrayDowngrading the Enterprise Virtual Array to v2.00x or v3.00xIf you wish to downgrade the existing V

Strona 7 - List of Tables

Chapter 4. Downgrading the Enterprise Virtual ArrayNoteThe software loads in pa rallel on the FC drive enclosures. During the software downgrade,the E

Strona 8

Appendix A. Software Upgrade FlowchartThis appendix provides a flowchart of the Enterprise Virtual Array software upgrading process.105hp StorageWorks

Strona 9 - About this

Appendix A. Software Upgrade Flowchart106hp StorageWorks Enterprise Virtual Array Updating ProductSoftware Instructions

Strona 10 - Conventions

Appendix A. Software Upgra de Flowcharthp StorageWorks Enterprise Virtual A rray Updating ProductSoftware Instructions107

Strona 11 - Equipment symbols

Appendix A. Software Upgrade Flowchart108hp StorageWorks Enterprise Virtual Array Updating ProductSoftware Instructions

Strona 12 - Rack stability

Appendix A. Software Upgra de Flowcharthp StorageWorks Enterprise Virtual A rray Updating ProductSoftware Instructions109

Strona 13 - Getting help

About this GuideEquipment symbolsThe following equipment symbols may be found on hardware to which this guide pertains.They have the following meaning

Strona 14

Appendix A. Software Upgrade Flowchart110hp StorageWorks Enterprise Virtual Array Updating ProductSoftware Instructions

Strona 15 - Getting Started

Appendix A. Software Upgra de Flowcharthp StorageWorks Enterprise Virtual A rray Updating ProductSoftware Instructions111

Strona 16 - Intended audience

Appendix A. Software Upgrade Flowchart112hp StorageWorks Enterprise Virtual Array Updating ProductSoftware Instructions

Strona 17 - Chapter 1. Getting Started

Appendix A. Software Upgra de Flowcharthp StorageWorks Enterprise Virtual A rray Updating ProductSoftware Instructions113

Strona 19

Appendix B. Software Version WorksheetAs you perform the procedures in this guide, use Table B.1 in this appendix to record thenecessary software vers

Strona 20 - Required licenses

Appendix B . Software Version WorksheetNotes116hp StorageWorks Enterprise Virtual Array Updating ProductSoftware Instructions

Strona 21 - Anti virus software

Appendix C. Troubleshooting SMI-S EVAStarting and stopping SMI-S EVAYou can manually start and stop SMI-S EVA from the Storage Management ApplianceMan

Strona 22 - Reference docu

Appendix C. Troubleshooting SMI-S EVATroubleshooting SMI-S EVAThis section explains the commonly-occurring problems that you may face with SMI-S EVA.T

Strona 23 - Location

Appendix D.StorageNetworkingIndustryAssociation Public LicenseSTORAGE NETWORKING INDUSTRY ASSOCIATIONPUBLIC LICENSEVersion 1. 1_______________________

Strona 24

About this GuideRack stabilityRack stability protects personnel and equipment.WarningTo reduce the risk of personal injury or damage to the equipment,

Strona 25 - Chapter 2

Appendix D. Storage Networking Industry Association Public License1.10 "Licensable" means having the right to grant, to the maximum extent p

Strona 26 - Compatibility

Appendix D. Storage Networking Indus try A ssociation P ublic Li cense2.2 Contributor Grant. Subject to third party intellectual property claims, each

Strona 27 - Software Compatibility

Appendix D. Storage Networking Industry Association Public Licensea. Third Party Claims. If Contributor has actual knowledge that a license under a th

Strona 28 - Table 2.4. Elem

Appendix D. Storage Networking Indus try A ssociation P ublic Li censeproduct. In such a case, You must make sure the requirements of this License are

Strona 29 - Array to v

Appendix D. Storage Networking Industry Association Public Licensesurvive any termination of this License. Provisions which, by their nature, must rem

Strona 30

Appendix D. Storage Networking Indus try A ssociation P ublic Li censeshall be reformed only to the extent necessary to make it enforceable. This Lice

Strona 32 - Properties page

Glossar yThis glossary defines terms used in this guide or related to this product and is not acomprehensive glossary of computer terms.active member

Strona 33

Glossarydisk drive enclosure A unit that holds storage system devices such as disk drives, power supplies,blowers, I/O modules, transceivers, or EMUs.

Strona 34

GlossaryGb Gigabit. A measurement of the rate at which the transfer of bits of dataoccurs. Sometimes referred to as Gbps. Nominally, a Gb is a transfe

Strona 35 - (Initialized system) page

About this GuideGetting helpIf you still have a question after reading this guide, contact an HP authorized service provideror access our website: htt

Strona 36

GlossaryAlso called a shutdown upgrade.online upgrade During an online upgrade of the storage system software, VCS is upgraded onthe HSV controllers,

Strona 37

GlossaryVCS Virtual Controller Software. Provides storage controller software capabilityfor the HSV controller.Vdisk Virtual Disk. A simulated disk dr

Strona 39

IndexIndexSymbols5% free disk space, 36, 13, 18AAdd a license page, 71add-on licenses, 28adding licenses, 70administrator privileges, 45administrator

Strona 40

IndexCCA EVA v1.1, 21caution, downgrading storage system, 30, 103CD-ROM installation, Storage Management Appliance software, 44checking EVA health, ti

Strona 41

Indexdisabling SNMP notification, 99disk group configuration, 35Disk Group Properties page, 36documentconventions, 10prerequisites, 18Documentation CD

Strona 42

IndexGgetting help, 13Hhardware errors, 31hardware status, 75help, obtaining,13Home page, 52host I/O, stopping, 74host kits, release notes, 23, 25host

Strona 43

Indexkits, required, 18kits, software, 18Ll, 82LEDs, checking status, 31license fulfillment website, 71license keys, adding, 71licensesloading, 70rede

Strona 44 - Wizard—installation types

Indexoperating systems, and JREs, 20operating systems, recommended browsers, 20OS timeouts, 29OV SAM, 19, 98Ppassword protection, 82password protectio

Strona 45

Indexsoftware tracking, 115SSSU, 47Stop Applications wizard, 54stopping Command View EVA, 54StorageAreaManager,98StorageAreaManager migration, 98Stora

Strona 47

Indexenabling password access, 82host server upgrades, 47loadingadd-onlicenses, 70migrating Network View, 98redeeming license keys, 40upgrading Busine

Strona 48

IndexVdisk Active Member Properties page, 38Vdisk Family Properties page, 38Vdisk Folder Properties page, 37verifying software version, 45, 67View Eve

Strona 49

Chapter 1.Getting StartedThis chapter provides information about the intended audience, required kits, and referencedocumentation. Please ensure that

Strona 50 - System page

Chapter 1. Getting StartedIntended audienceThis document is intended for customers who need to upgrade the StorageWorks EnterpriseVirtual Array (EVA)

Strona 51

Chapter 1. Getting StartedHP recommends that you review the documentation listed in Table 1.1 to familiarize yourselfwith the various hardware and sof

Strona 52

Chapter 1. Getting StartedPrerequisitesThis section lists the required tools for successful upgrades and downgrades of the softwarein the Enterprise V

Strona 53 - Click Manage Tools

Chapter 1. Getting StartedIn addition to documentation, this kit contains the following:• HP StorageWorks Enterprise Virtual Array System Software Ver

Strona 54 - HSV Element Manager

Copyright © 1998-2004 Hewlett-Packard Development Company, L.P.Hewlett-Packard Company makes no warranty of any kind with regard to this material, inc

Strona 55 - Figure 3

Chapter 1. Getting StartedRecommended browsers and Java™ Runtime EnvironmentsTable 1.2 lists the recommended browsers for running Storage Management A

Strona 56

Chapter 1. Getting Startedmust obtain the appropriate licenses before you begin the upgrade procedure described inChapter 3: Upgrading the Enterprise

Strona 57

Chapter 1. Getting StartedReference documentationTable 1.3 liststhe documents to which you might refer during the upgrade and downgradeprocesses. The

Strona 58

Chapter 1. Getting StartedTitleLocationHP StorageWorks Business CopyEVA/MA/EMA Host Agentv2.2 for Windows InstallationGuide(T3032-961 07)http://h18006

Strona 59

Chapter 1. Getting StartedTitleLocationHP StorageWorks OpenVMS KitV3.0E for Enterprise Virtual ArrayInstallation and Configuration Guide(AA-RUGUC-TE)h

Strona 60

Chapter 2.Software Compatibility MatricesThe Enterprise Virtual Array uses various software that work with each other to manage thestorage solution. W

Strona 61 - Wizard—installation complete

Chapter 2 . Software Compatibility MatricesTable 2.1 indicates the compatible versions of element manager software and storage systemsoftware. Command

Strona 62

Chapter 2. Software Compatibility MatricesTable 2.2 indicates the compatible versions of VCS and Enterprise Virtual Array. TheEVA3000 storage system u

Strona 63

Chapter 2 . Software Compatibility MatricesTable 2.4 indicates the compatible versions of the element manager software and add-onlicenses such as, Bus

Strona 64

Chapter 3.Upgrading the Enterprise VirtualArray to v3.020Upgrading from Enterprise Virtual Array v3.0xx to v3.020 involves several steps, whichmust be

Strona 65 - C:\Compaq\SWPInstallKits

Table of ContentsAbout this Guide... 9Conventions ...10Documentconventions...

Strona 66 - Wizard—select file

Chapter 3. U pgrading the Enterprise Virtual Array to v3.020• Step 1: Checking the health of the Enterprise Virtual Array• Step 2: Redeeming license k

Strona 67

Chapter 3. Upgrading the Enterprise Virtual Array to v3.020Step 1: Checking t he health of the Enterprise Virtual ArrayEstimated Time to Complete1 hou

Strona 68

Chapter 3. U pgrading the Enterprise Virtual Array to v3.020Figure 3.1. Command View EVA—Hardware folder inthe Navigation paneb. Click the Hardware fo

Strona 69 - Important

Chapter 3. Upgrading the Enterprise Virtual Array to v3.020d.Click the component icon to display the properties page. The Operational statefield indic

Strona 70

Chapter 3. U pgrading the Enterprise Virtual Array to v3.020Figure 3.4. Command View EVA—Disk EnclosureProperties page—checking the firmware versione.

Strona 71

Chapter 3. Upgrading the Enterprise Virtual Array to v3.020Figure 3.5. Command View EVA—View Events pagec.Click Controller Event Log.The Controller Ev

Strona 72 - Click Add license

Chapter 3. U pgrading the Enterprise Virtual Array to v3.020a. In Command View EVA, click the Disk Group folder in the Navigation pane.The Disk Group

Strona 73 - Step 8: Upgradi

Chapter 3. Upgrading the Enterprise Virtual Array to v3.020Figure 3.8. Command View EVA—Disk Group Propertiespage—checking free capacity9. Check the V

Strona 74

Chapter 3. U pgrading the Enterprise Virtual Array to v3.020Figure 3.9. Command View EVA—Vdisk FolderProperties pageNoteIf you are using virtual disk

Strona 75

Chapter 3. Upgrading the Enterprise Virtual Array to v3.020Figure 3.11. Command View EVA—Vdisk Active MemberProperties paged.Check the Redundancy fiel

Strona 76

Uninstalling SMI-S EVA . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84Installing SMI-S EVA on the Storage Management Appliance . . . . . .

Strona 77

Chapter 3. U pgrading the Enterprise Virtual Array to v3.020Step 2: Redeeming license keysEstimated Time to Complete1to48hoursVerify that you have the

Strona 78

Chapter 3. Upgrading the Enterprise Virtual Array to v3.020CautionIfyouhaveAuditorEventlogfilesthatarelargerthanthenewmaximumsizes,andyouwant to retai

Strona 79

Chapter 3. U pgrading the Enterprise Virtual Array to v3.020Figure 3.12. Storage Management Appliance software—Settings page5.Click Maintenance in the

Strona 80

Chapter 3. Upgrading the Enterprise Virtual Array to v3.020Figure 3.14. Storage Management Appliance software—Installation Wizard7.Click Next at the b

Strona 81

Chapter 3. U pgrading the Enterprise Virtual Array to v3.020Figure 3.15. Storage Management Appliance software—InstallationWizard—installation types8.

Strona 82

Chapter 3. Upgrading the Enterprise Virtual Array to v3.020When the installation finishes, the Storage Management Appliance reboots and theStorage Man

Strona 83

Chapter 3. U pgrading the Enterprise Virtual Array to v3.020Figure 3.16. Storage Management Appliance Online Help46hp StorageWorks Enterprise Virtual

Strona 84 - Uninstalling SMI-S EVA

Chapter 3. Upgrading the Enterprise Virtual Array to v3.020Step 4: Upgrading host serversEstimated Time to Completevaries by host type (see Table 3.2)

Strona 85

Chapter 3. U pgrading the Enterprise Virtual Array to v3.020Step 5: Clearing t he passwords on the HSV controllersEstimated Time to Complete15 minutes

Strona 86

Chapter 3. Upgrading the Enterprise Virtual Array to v3.020Figure 3.17. Command View EVA—Management Agent Options page3.Click Storage system password

Strona 87

List of Figures3.1. Command View EVA—Hardware folder in the Navigation pane . . . . . . . . . . . . . . . 323.2.CommandViewEVA—HardwareFolderPropertie

Strona 88

Chapter 3. U pgrading the Enterprise Virtual Array to v3.020Figure 3.19. Command View EVA—Disable Password Access to StorageSystem page5. Select the s

Strona 89 - Configuring SMI -S EVA

Chapter 3. Upgrading the Enterprise Virtual Array to v3.020Step 6 : Upgrading Command View EVAEstimated Time to Complete45 minutesThis section contain

Strona 90 - JAAS.policy

Chapter 3. U pgrading the Enterprise Virtual Array to v3.0202. From a client computer, launch a Web browser and browse to the Storage ManagementApplia

Strona 91

Chapter 3. Upgrading the Enterprise Virtual Array to v3.020Figure 3.22. Storage Management Appliance software—Settings page5.Click Manage Tools.The Ma

Strona 92 - Administrator

Chapter 3. U pgrading the Enterprise Virtual Array to v3.020Figure 3.23. Storage Management Appliance software—Manage Tools page6.Select the command v

Strona 93

Chapter 3. Upgrading the Enterprise Virtual Array to v3.020Figure 3.24. Storage Management Appliance software—Stop Applicationswizard8.Click Next.A me

Strona 94 - SSL support

Chapter 3. U pgrading the Enterprise Virtual Array to v3.020Figure 3.25. Storage Management Appliance software—Stop Applicationswizard—successful mess

Strona 95 - Enabling SSL

Chapter 3. Upgrading the Enterprise Virtual Array to v3.020Figure 3.26. Storage Management Appliance software—Maintenance page13. Determine the instal

Strona 96

Chapter 3. U pgrading the Enterprise Virtual Array to v3.020Figure 3.27. Storage Management Appliance software—Installation Wizard3.Click Next at the

Strona 97 - Step 11: Upgrad

Chapter 3. Upgrading the Enterprise Virtual Array to v3.020Figure 3.28. Storage Management Appliance software—InstallationWizard—installation types4.C

Strona 98 - Step 14 : Inst

3.43. Command View EVA—Initialized Storage System Properties page . . . . . . . . . . . . . 753.44.CommandViewEVA—firstcodeloadconfirmationmessage...

Strona 99 - Step 15: Disabl

Chapter 3. U pgrading the Enterprise Virtual Array to v3.020Figure 3.29. Storage Management Appliance software—InstallationWizard—installation in prog

Strona 100

Chapter 3. Upgrading the Enterprise Virtual Array to v3.020Figure 3.30. Storage Management Appliance software—InstallationWizard—installation complete

Strona 101 - Chapter 4

Chapter 3. U pgrading the Enterprise Virtual Array to v3.020Figure 3.31. Storage Management Appliance software—Devices page12.Verify that a command vi

Strona 102 - Software Instructions

Chapter 3. Upgrading the Enterprise Virtual Array to v3.020Figure 3.32. Storage Management Appliance software—InstallationWizard—FTP server installati

Strona 103

Chapter 3. U pgrading the Enterprise Virtual Array to v3.020The management appliance returns to the Maintenance page.9.Click Devices in the tool bar.T

Strona 104

Chapter 3. Upgrading the Enterprise Virtual Array to v3.020NoteMake sure that the .SWP file is in theC:\Compaq\SWPInstallKitsdirectory. TheInstallatio

Strona 105 - . Software Upgrade Flowchart

Chapter 3. U pgrading the Enterprise Virtual Array to v3.0207.Click Next at the bottom of the page.The screen returns with the file display name Comma

Strona 106

Chapter 3. Upgrading the Enterprise Virtual Array to v3.020Figure 3.36. Storage Management Appliance software— Devices page10.Verify that a command vi

Strona 107

Chapter 3. U pgrading the Enterprise Virtual Array to v3.020Figure 3.37. Command View EVA—HSV Storage Network Properties page5.Click Help in the Sessi

Strona 108

Chapter 3. Upgrading the Enterprise Virtual Array to v3.020Figure 3.39. Command View EVA Help—About pageImportantIf you are not using a recommended br

Strona 109

List of Tables1. DocumentConventions...101.1.RelatedDocumentation ...171.2.RecommendedBrowser

Strona 110

Chapter 3. U pgrading the Enterprise Virtual Array to v3.020Step 7: Loading the add-on licensesEstimated Time to Complete5 minutes per licenseIf you a

Strona 111

Chapter 3. Upgrading the Enterprise Virtual Array to v3.020Figure 3.41. Command View EVA — Licensing Options page4.Click Enter new license key.The Add

Strona 112

Chapter 3. U pgrading the Enterprise Virtual Array to v3.0207.Click Add license.8. To enter additional license keys, repeat step 5 through step 7 for

Strona 113

Chapter 3. Upgrading the Enterprise Virtual Array to v3.020Step 8: Upgrading the VCS/Storage System Software to v3.020Estimated Time to Complete45 min

Strona 114

Chapter 3. U pgrading the Enterprise Virtual Array to v3.020During a rolling upgrade of the storage system software, VCS is upgraded on the HSVcontrol

Strona 115 - Appendix B

Chapter 3. Upgrading the Enterprise Virtual Array to v3.020Figure 3.43. Command View EVA—Initialized Storage System Propertiespage3. Check the status

Strona 116

Chapter 3. U pgrading the Enterprise Virtual Array to v3.020CautionYou cannot load code onto the controllers if:• The storage configuration is being c

Strona 117 - . Troubleshooting SMI-S EVA

Chapter 3. Upgrading the Enterprise Virtual Array to v3.020Figure 3.45. Command View EVA—Code Load Storage System-Page 18. Insert the installation CD-

Strona 118 - Troubleshooting SMI-S EVA

Chapter 3. U pgrading the Enterprise Virtual Array to v3.020Figure 3.46. Command View EVA—Code Load Storage System-Page 211.Click Next Step.A confirma

Strona 119 - Associat

Chapter 3. Upgrading the Enterprise Virtual Array to v3.020Figure 3.48. Command View EVA—upgrade confirmation message13.Click OK to confirm that you h

Strona 121

Chapter 3. U pgrading the Enterprise Virtual Array to v3.020Figure 3.50. Command View EVA—Code Load Storage System-Page 3NoteThesoftwareloadsinparalle

Strona 122

Chapter 3. Upgrading the Enterprise Virtual Array to v3.020Figure 3.51. Command View EVA—EMU firmware update message15.Click OK.16. Refresh the browse

Strona 123

Chapter 3. U pgrading the Enterprise Virtual Array to v3.020Step 9: Adding passwords to the HSV controllers (optional)Estimated Time to Complete15 min

Strona 124

Chapter 3. Upgrading the Enterprise Virtual Array to v3.020Figure 3.53. Command View EVA—Enable Password Access to a StorageSystem page5. Select the W

Strona 125

Chapter 3. U pgrading the Enterprise Virtual Array to v3.020Step 10: Installing SMI-S EVA (optional)HP StorageWorks SMI-S EVA v3.2 provides the Storag

Strona 126

Chapter 3. Upgrading the Enterprise Virtual Array to v3.020NoteThedefaultappliancenameforaStorageManagementAppliance(hardwareversion1.0)begins withswm

Strona 127 - Glossar y

Chapter 3. U pgrading the Enterprise Virtual Array to v3.020Installing from a CD-ROMComplete the following procedure to install SMI-S EVA v3.2 on the

Strona 128 - Glossary

Chapter 3. Upgrading the Enterprise Virtual Array to v3.020Installation is complete.Installing hp StorageWorks SMI-S for EVA <Date> <Time>

Strona 129

Chapter 3. U pgrading the Enterprise Virtual Array to v3.020NoteThe default appliance name for a Storage Management Appliance (hardware version 1.0)be

Strona 130

Chapter 3. Upgrading the Enterprise Virtual Array to v3.020NoteIn some cases, the message, Rebooting this Appliance,isdisplayed.If the installation fa

Strona 131

About thisGuideThis guide provides information to help you:• Upgrade the Storage Management Appliance software, Command View EVA, and VirtualControlle

Strona 132

Chapter 3. U pgrading the Enterprise Virtual Array to v3.020Modify the configuration files as indicated in Table 3.5.Table 3.5. Configuration FilesFil

Strona 133

Chapter 3. Upgrading the Enterprise Virtual Array to v3.020EVAprovider.propertiesConfigure EVAprovider.properties files as indicated in Table 3.6.Tabl

Strona 134

Chapter 3. U pgrading the Enterprise Virtual Array to v3.020NoteDonotmodifyanyparameterthatisnotlistedinTable 3.7.Table 3.7. Cim.properties FileFieldP

Strona 135

Chapter 3. Upgrading the Enterprise Virtual Array to v3.020NoteThe parameter Group is one of the groups listed by the -LG option. A user name can exis

Strona 136

Chapter 3. U pgrading the Enterprise Virtual Array to v3.0204.Click Set Options.The System Options page displays.5.Select Configure event notification

Strona 137

Chapter 3. Upgrading the Enterprise Virtual Array to v3.020clients with the ability to authenticate the entity claiming to be the SMI-S server, and al

Strona 138

Chapter 3. U pgrading the Enterprise Virtual Array to v3.020NoteSee Port occupation for more information.Viewing certificates using the keytool com m

Strona 139

Chapter 3. Upgrading the Enterprise Virtual Array to v3.020Step 11: Upgrading Business Copy EVA (if installed)Estimated Time to Complete45 minutesIf y

Strona 140

Chapter 3. U pgrading the Enterprise Virtual Array to v3.020Step 12: Upgrading Continuous Access EVA (if installed)Estimated Time to Complete45 minute

Strona 141

Chapter 3. Upgrading the Enterprise Virtual Array to v3.020Step 15: Disabling SNMP notification to the PRS h ostSome Enterprise Virtual Arrays run the

Komentarze do niniejszej Instrukcji