Hp Array Controller HSG V8.7 Software Instrukcja Użytkownika Strona 201

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 200
Replacement Procedures 55
6. See Configuring an HSG80 Array Controller, page 23, to configure
the controller.
Note If the controller youre installing was previously used in another
subsystem, it will need to be purged of the controllers old
configuration (see CONFIGURATION RESET, page B45).
7. To restore a configuration saved with the SAVE_CONFIGURATION
switch, hold button 6 while releasing the reset button.
8. Using CLCP, install any patches that you had installed on the previous
controller (see Installing a Software Patch, page 66).
9. Mount the logical units on the host. If you are using a Windows NT
platform, restart the server.
10. Set the subsystem date and time with the following command:
SET THIS_CONTROLLER TIME=dd-mmm-yyyy:hh:mm:ss
11. Disconnect the PC or terminal from the controllers maintenance port.
Przeglądanie stron 200
1 2 ... 196 197 198 199 200 201 202 203 204 205 206 ... 575 576

Komentarze do niniejszej Instrukcji

Brak uwag