220 HSG80 Users Guide
Table 24 Key to Figure 27 Cabling for Dual-Redundant
Configuration with Two Hubs (optical)
1. Stop all I/O from the host to its devices on the bus to which you are
connecting the controllers.
2. Connect the Fibre Channel cable from Port 1 on controller A to Port 9
on hub 1. Repeat this step to connect the second cable from Port 1 on
controller B to Port 8 on hub 1.
3. Connect another Fibre Channel cable from Port 2 on controller A to Port
1 on hub 2. Repeat this step to connect the final cable from Port 2 on
controller B to Port 2 on hub 2.
4. Connect each hub to their respective host according to the instructions
in the Getting Started manual.
5. Route and tie the cables as desired.
6. Restart the I/O from the host. Some operating systems may require you
to restart the host to see the devices attached to the new controller.
Item Description Part No.
1Dual Controller
2 12-Port Fibre Channel HUB DHGGA-CA
3 .5 M Fibre Channel Optic cable
1 M Fibre Channel Optic cable
2 M Fibre Channel Optic cable
3 M Fibre Channel Optic cable
5 M Fibre Channel Optic cable
10 M Fibre Channel Optic cable
20 M Fibre Channel Optic cable
30 M Fibre Channel Optic cable
50 M Fibre Channel Optic cable
100 M Fibre Channel Optic cable
200 M Fibre Channel Optic cable
400 M Fibre Channel Optic cable
170482001
170482002
170482003
170482004
170482005
170482006
170482007
170482008
170482009
170482010
170482011
170482012
Przeglądanie stron 73