D2 HSG80 Users Guide
Passthrough Device Reset Event Sense Data Response
Events reported by passthrough devices during host/device operations
are conveyed directly to the host system without intervention or
interpretation by the HSG80controller, with the exception of device
sense data that is truncated to 160 bytes when it exceeds 160 bytes.
Events related to pass-through device recognition, initialization, and
SCSI bus communication events that result in a reset of a pass-through
device by the HSG80 controller are reported using standard SCSI Sense
Data, as shown in Figure D1. For all other events, refer to the
templates to follow.
Instance Codes (byte offset 32-35) are described in Table D1,
Instance Codes on page D18.
ASC and ASCQ codes (byte offsets 12 and 13) are described in
Table D7, ASC and ASCQ Codes on page D85.
Figure D1 Pass-through Device Reset Event Sense Data
Response Format
off bit 7 6 5 4 3 2 1
Valid
Segment
FM
Information
Instance Code
Field Replaceable Unit Code
Error Code
0
1
2
3-6
7
8-11
12
13
14
15
16
17
0
Sense Key
Additional Sense Length
Additional Sense Code (ASC)
Additional Sense Code Qualifier (ASCQ)
Sense Key Specific
CXO-5093A-MC
EOM ILI Rsvd
SKSV
Przeglądanie stron 435