Hp PCIe U320 SCSI Host Bus Adapter Instrukcja Użytkownika Strona 1

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Przechowywanie Hp PCIe U320 SCSI Host Bus Adapter. HP PCIe U320 SCSI Host Bus Adapter User Manual [es] Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 0
HP StorageWorks U320e SCSI Host Bus
Adapter
User guide
AH627-96001
Part number: AH6279600 1
1
st edition: March 2007
Przeglądanie stron 0
1 2 3 4 5 6 ... 60 61

Podsumowanie treści

Strona 1 - User guide

HP StorageWorks U320e SCSI Host BusAdapterUser guideAH627-96001Part number: AH627–9600 11st edition: March 2007

Strona 2

10About this guide

Strona 3 - Contents

1 FeaturesThe HP StorageWorks U320e SCSI Host Bus Adapter represents the seventh generation of parallel SCSItechnology, an I/O interface that is commi

Strona 4

12Features

Strona 5

2 InstallationCAUTION:Back up your system data before changing or installing hardware.Follow the steps in this chapter to install the host bus a d apt

Strona 6

WARNING!When installing the adapter in a server in a rack, to reduce the risk of p ersonal injur y or damage to theequipment, adequately stabilize the

Strona 7

The last device in the bus — that farthest from the adapter — must be properly terminated for eachSCSI bus. When planning device termination, keep the

Strona 8

b. Use a sm all, flat screwdriver to remove the four stand-offs on the external connectors, asshown in Figure 3.11315Figure 3 Removing t he stand-offsc

Strona 9 - Documentation

Installing the adapter hardwareCAUTION:Electrostatic discharge can damage electronic components. Be sure you are properly grounded bef orebeginning th

Strona 10 - About this guide

4. Poweruptheserverandperipherals.The HP U320e SCSI Host Bus Adapter comes pre-configured to operate properly in a variety of commonsetups. However, so

Strona 11 - 1 Features

2. Unzip the driver package and view the readme.txt file for release notes and installationinstructions.HP provides patches for the AH627A driver in th

Strona 12 - Features

Legal and notice information© Copyright 2007 H ewlett-Packard Development Company, L.P.Confidential computer software. Valid license from HP required f

Strona 14 - Planning the installation

3 SCSI D omain Validation utility(Windows only)The SCSI Domain Validation utility tests the physical connection between host adapter and devicesto ens

Strona 15

5. Follow the directions in the installer to finish the installation.Running the Domain Validation utilityToruntheATTOSCSIDomainValidationtool:1. Launc

Strona 16 - Preparing the ser ver

The SCSI Domain Validation help text provides useful information about setting up the tests. Review thehelp text for a more detailed explanation of th

Strona 17 - Connecting the devices

24SCSI Domain Validation utility ( Windows only)

Strona 18 - Installing drivers

4Configuration toolThe HP StorageWorks U320e SCSI Host Bus Adapter ships with the latest firmware installed andconfiguration set to work in m ost install

Strona 19 - Updating firmwa

Using the Configuration ToolNOTE:The HP StorageWorks U320e SCSI Host Bus Adapter is designed to operate properly using factorysettings. Entering invali

Strona 20 - Installation

to the adapter and channel selected. See "NV RAM settings" on page 27 for information about theNVRAM settings.PCI information is displayed i

Strona 21 - (Windows only)

Fallback SyncRate (MB/s)Choices: 40/20, 20/10, and 10/5Default: 40/20Spec ifies the maximum synchronous transfer rate to be negotiated when theadapter

Strona 22 - Running the Dom

Sync Rate (MB/s) Choices: Sync DT IU (320, 160), Sync DT (160, 80, 40), Sync ST WIDE(80, 40, 20, 10), Sync ST Narrow (40, 20, 10, 5)Default: Sync DT I

Strona 23

ContentsAboutthisguide ... 7Intendedaudience... 7Documentconventionsandsymbols ...

Strona 24

30Configuration tool

Strona 25 - 4Configuration tool

5 Trou bleshootin gThis chapter describes troubleshooting techniques that can be used to identify and resolve issuesassociated with the HP StorageWork

Strona 26 - Using the Configuration Tool

Windows installation troubleshootingWhen working properly, the ATTO Technology Banner should appear shortly after booting the computer,as shown in Fig

Strona 27 - NVR AM setting

SymptomsTroubleshooting stepsThe host adapter is installedin the computer but i t doesnot appear during the systemBIOS scan.• Check the adapter in sta

Strona 28 - Configuration tool

SymptomsTroubleshooting step sThe host adapter is detectedduring the system's BIOS scanbutitisnotdetectedbytheoperating system.When working prope

Strona 29

Linux installation t roubleshootingTable 5 Linux troubleshooting tableSymptomsTroubleshooting stepsThe host adapter driverwas loaded properly andevery

Strona 30

SymptomsTroubleshooting step sThe host adapter isrecognized, but it does notdetect any of the connectedSCSI devices.The command dmesg can be used to s

Strona 31 - 5 Trou bleshootin g

Table 7 Messages from Flash tab ac tionsError messageSolutionThis is not a flash file,oritiscorrupt.The flash file is corrupt or the Configuration To ol do

Strona 32

Increase transfer sizeIf you are writing to an application that uses a lot of sequential disk I/O to a contiguous area on disk,you should use as large

Strona 33 - Troubleshooting steps

6 Technical specificationsEnvironmental and physical specifications:• Operating temperature: 0–45 °C• Humidity: 10–90% non-condensing• Airflow: 100 LFM (

Strona 34 - Troubleshooting step s

6 Technical specifications ... 39ARegulatorycomplianceandsafety... 41Regulatorycompliance...

Strona 35 - Linux installat

40Technical specifications

Strona 36 - Configuration Tool messages

A Regulatory com pliance a ndsafet yRegulatory complianceRegulatory compliance identification numbersFor the purpose of regulatory compliance cer ti fic

Strona 37 - Use the latest driver

Class B equipmentThis equipment h as been tested and found to comply with the limits for a Class B digital device, p ursuantto Part 15 of the FCC Rule

Strona 38 - Analyz e your I/Os

Laser safety warningWARNING!To reduce the risk of exposure to hazardous radiation:• Do not try to open the laser device enclosure. There are no user-s

Strona 39 - 6 Technical specifications

Japanese noticeKorean noticesSafetyTaiwan battery recycling noticeThe Taiwan EPA requires dry battery manufacturing orimporting firmsinaccordancewithAr

Strona 40 - Technical specifications

and current rating marked on the product. In addition, the diameter of the wire must be a minimum of1.0 0 m m2or 18 AWG, and the length of the c ord m

Strona 41 - A Regulatory com pliance a nd

Dutch noticeVerwijdering van afgedankte apparatuur door privé-gebruikers in de Europese UnieDit symbool op het product of de verpakking geeft aan dat

Strona 42 - Laser device

Finnish noticeLaitteiden hävittäminen kotitalouksissa Euroopan unionin alueellaJos tuotteessa tai sen pakkauksessa on tämä merkki, tuotetta ei saa häv

Strona 43 - BSMI notice

Greek notice. ,..,,.Hungarian noticeKészülékek magánháztartásban történ selejtezése az Európai Unió területén A készüléken, illetve a készülék csomag

Strona 44 - Power cords

Italian noticeSmaltimento delle apparecchiature da parte di privati nel territorio dell'Unione EuropeaQuesto simbolo presente sul prodotto o sull

Strona 45 - Danish notice

Figures1..Kitcontents ... 132..Removingthebracketscrews... 153..Removing thestand-offs ...

Strona 46 - English notice

Lihuanian noticeNolietotu iek rtu izn cin šanas noteikumi lietot jiem Eiropas Savien bas privtaj s m jsaimniec b sŠds simbols uz izstr d juma vai uz t

Strona 47 - German notice

Portuguese noticeDescarte de Lixo Elétrico na Comunidade Européia Este símbolo encontrado no produto ou na embalagem indica que o produto não deve se

Strona 48 - Hungarian notice

Spanish noticeEliminación de residuos de equipos eléctricos y electrónicos por parte de usuarios particulares en la Unión EuropeaEste símbolo en el pr

Strona 49 - Latvian notice

B Electrostatic dischargeTo prevent damaging the system, be aware of the precautions you need to follow when setting up thesystem or handling parts. A

Strona 50 - Polish notice

54Electrostatic discharge

Strona 51 - Slovenian notice

GlossaryANSI American National Standards Institutearbitrate Process of selecting one L_ Port from a collection of ports which ask for use ofthe arbitr

Strona 52 - Swedish notice

is almost complete so that it can prepare for the next transfer while the targetcompletes the current transfer.full duplex A communication protocol wh

Strona 53 - B Electrostatic discharge

process by eliminating the bus free phase. When combined with packetization,reduces command overhead and m aximizes bus use.read and writedata streami

Strona 55 - Glossary

In dexAaudience,7Avis Canadien, regulatory compliance notice,43BbatteriesTaiwan EPA recycling and disposal,44boot straps, using,53BSMI, regulatory com

Strona 56

Tables1 ..Documentconventions... 72..SCSIcapabilities... 143..Tabs displayedbydevicetype ...

Strona 57

installationconnecting devices,17drivers,18installing the adapter hardware,17planning,14preparing the server,16replacing the bracket,15system requirem

Strona 58

Wwarningslasers, radiation,43waste electrical and electronic equipmentdirective,45waste equipment disposal for EU privatehouseholds,46websitescustomer

Strona 59

About this guideThis guide provides information about:• installing and connecting devices to the H P StorageWorks U320e SCSI Host Bus Adapter• configur

Strona 60

NOTE:Provides additional information.TIP:Provides helpful hints and shortcuts.HP technical supportFor worldwide technical support information, see the

Strona 61

•http://www.hp.com/support/downloadsDocumentationfeedbackHP welcomes your feedback.To make comments and suggestions about product documentation, pleas

Komentarze do niniejszej Instrukcji

Brak uwag