Hp XP Continuous Access Software Instrukcja Użytkownika Strona 111

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 110
RAID Manager command reference 111
array, check the RM command device name before
using this argument.
–C Changes and displays the RM command device being
used by the RM.
If the command device is blocked due to the online
maintenance (microprogram replacement) of the disk
array, check the RM command device name before
using this argument.
By using this argument again after completion of the
online maintenance (microprogram replacement), the
previous command device is reinstated.
–u unitid This argument is in effect when the –D or –C argument
is specified. It specifies the unit ID of a command
device as the target.
If this argument is omitted, unit IDs are 0.
–ND –g group Displays the network address and port name being used
by RM.
–NC –g group Changes the network address and port name being used
by RM and displays the changed network address
name.
–g group Specifies the group name written in the configuration
definition file.
Example Entering horcctl –D –C identifies a protection mode command device by
adding “*” to the device name as follows:
HP-UX
# horcctl -D
Current control device = /dev/rdsk/c0t0d0*