246 HP StorageWorks Disk Array XP RAID Manager: User’s Guide
BR-W-E-E displays the flags for checking data block
size.
R=Read → E=Enable and D=Disable
W=Write → E=Enable and D=Disable
E=Endian format → L=Little and B=Big
E=Not rejected when validation error → W=Write
and R=Read
MR-W-B displays the flags for checking block header
information.
R=Read → E=Enable and D=Disable
W=Write → E=Enable and D=Disable
B=Block #0 → E=Enable and D=Disable
BR-W-B displays the flags for checking data block
number information.
R=Read → E=Enable and D=Disable
W=Write → E=Enable and D=Disable
B=Data Block → E=Enable and D=Disable
SR-W-B-S displays the flags for checking data block
checksum.
R=Read → E=Enable and D=Disable
W=Write → E=Enable and D=Disable
B=Block #0 → E=Enable and D=Disable
S=Checksum → E=Enable and D=Disable
–v offset
Displays the range setting for data block size of Oracle
I/O and a region on a target volume for validation
checking.
Bsize displays the data block size of Oracle I/O, in units
of bytes.
STLBA displays the Start of LBA on a target volume,
in units of LBAs.
ENLBA displays the End of LBA on a target volume,
in units of LBAs. If STLBA and ENLBA are both zero,
all blocks are checked.