0.1.en.04 CRITICAL condition—Loop a drive link rate incorrect
The drive is c apable of operating at the loop link rate but is running at a different rate. For example, the
drive is operat
ing at 1 Gbps, and the loop is operating at 2 Gbps. Only when the drive is operating at
the Fibre Chann
el link rate established by the I/O module can this drive transfer data.
This error remains active until the problem is corrected.
Complete the following procedure to correct this problem:
1. Record all six characters of the condition report.
2. Remove and rep
lace the drive in the enclosure.
3. Observe the drive status indicators to ensure the drive is operational.
4. Observe the EMU to ensure the error is corrected.
5. If removing a
nd replacing the drive did not correct the problem, replace the drive.
6. Observe the drive status indicators to ensure the drive is operational.
7. Observe the EMU to ensure the error is corrected.
8. If unable to
correct the problem, contact your authorized service representative.
0.1.en.05 CRITICAL condition—Loop b drive link rate incorrect
The drive is c apable of operating at the loop link rate but is running at a different rate. For example, the
drive is opera ting at 1 Gbps, and the loop is operating at 2 Gbps. Only when the drive is operating at
theFibreChannellinkrateestablishedbytheI/Omodulecanthisdrivetransferdata.
This error remains active until the problem is corrected.
Complete the following procedure to correct this problem:
1. Record all six characters of the condition report.
2. Remove a n d replace the drive in the enclosure.
3. Observe the drive status indicators to ensure the drive is operational.
4. Observe the EMU to ensure the error is corrected.
5. If removing and replacing the drive did not correct the problem, replace the drive.
6. Observe the drive status indicators to ensure the drive is operational.
7. Observe the EMU to ensure the error is corrected.
8. If unable to correct the problem, contact your authorize d service representative.
Power supply conditions
The format of a power supply condition report is 0.2.en.ec,where:
0.2. is the power supply element type number
en. is
the two-chara cter power supply element number
ec is the error code
Figure 4 7 shows the location of power supply 1 and power supply 2.