Przeglądanie stron 49
Both online high-performance disk drives and FATA disk drives in a variety of capacities and
spindle speeds.
Better vibration damping for improved performance.
Up to 14 disk drives can be installed in a drive enclosure.
Disk drive stat
us indicators
Three status indicators display the drive operational status. Figure 15 shows the disk drive status
indicators. Table 9 provides a description of each status indicator.
Figure 15 Disk drive status indi cators
1. A ct ivi t y
2. Online
3. Fault
Table 9 Dis
k drive sta tus indicator descriptions
Status indicator
Description
Activity
This green status indicator ashes when the disk drive is
being accessed. It is on when th e drive is idle.
Online
The green status indicator is on when the disk drive is
online a
nd operating normally. This indicator will be off
in the following situations:
There is no controller on the bus.
+5.1 VDC is not available.
The drive is not properly installed in the enclosure.
Fault
This amber status indicator is on when there is a disk drive
failure. Depending on the host controller, this indicator may
ash when the controller detects an error condition.
The amber status indicator ashes in synchronization with
the other two status indicators in response to the EMU
locate comma nd.
Disk drive status displays
The disk drive status indicators can assume three states: on, off, or ashing. The status indicators states
for operational drive status are shown in Table 1 0.SeeTable 11 for the non-operational drive status