Power supplies
The two power su
pplies mount in the rear of the enclosure. See Figure 16. The supplies are autoranging
and operate on
acountry-specicACinputvoltageof202to240VA10%,50to60Hz5%,(188
to264VAC,47to63Hz).
The DC outputs of this power supply are:
+5.1 VDC for th
eEMU,I/Omodule,backplane, and disk drives
+12.1 VD C for the disk drives
+12.5 VDC for the disk drives
The output of
each power supply is 499W, with a peak output of 681 W. A single power supply can
support an en
closure with a full complement of disks.
The power supply circuitry provides protection against:
Overloads
Short circu
its
Overheating
Power supply status and diagnostic information is reported to the EMU with voltage, current, and
temperature signals.
See Regulatory Notices and Specications for the enclosure pow er specications.
The power su
pply temperature sensor provides a temperature range signal to the EMU, which uses this
signal to set the blower speed.
The power supply internal temperature can also control the speed of the blower. The higher the power
supply temperature, the faster the speed of the blower. If the power supply temperature exceeds a preset
value, the power supply automatically shuts down.
Blowers
The power supplymounted blowers cool the enclosure by circulating air through the enclosure. The
blowers, under the control of the EMU or the associated power supply, can operate at multiple speeds.
This ensures that when the enclosure temperature changes the blowers can automatically adjust the
air ow .
If a blower is operating too slowly or has stopped (a “blower failure”), internal circuitry automatically
operates the remaining blower at a higher speed. Simultaneously, the error condition is reported in
several ways, including the power supply indicator, the audible alarm, the enclosure fault indicators,
and the EMU alphanumeric display.
Should both blowers fail, the power supplies automatically shut down.
NOTE:
The blowers are eld-replaceable units and can be replaced, individually, while the system is running.
The blowers are also interchangeable. The failure of a power supply +12.5 VDC circuit disables
the associated blower.
The status indicator on the blower displays the status of both the power supply and the blower. See
Figure 16.SeeTable 12 for denitions of the indicator displays.
52
Enterprise Virtual Array hardware components