HP NetServer DiagToolsError Reference and User GuidePrinted in September 1998

Strona 2 - Audience Assumptions

Chapter 2 Preparing to Run DiagTools6Once the installation is complete, the Utility Partition (with DiagTools included) will be ready for use. Seechap

Strona 3 - Contents

Chapter 2 Preparing to Run DiagTools7

Strona 5 - 1 DiagTools Overview

93 Running DiagTools in the Graphical Mode (fromDiskette)Once you have completed the steps in chapter 2 under “How to Make a DiagTools Diskette,” you

Strona 6 - DiagTools Capabilities

Chapter 3 Running DiagTools in the Graphical Mode (from Diskette)10Before continuing, ensure that the followingare correctly configured...Starting Con

Strona 7 - About Error Messages

Chapter 3 Running DiagTools in the Graphical Mode (from Diskette)11Interpreting Basic Test ResultsOnce you run the DiagTools Basic Tests, you can see

Strona 8 - Chapter 1 DiagTools Overview

Chapter 3 Running DiagTools in the Graphical Mode (from Diskette)12Running the Advanced System TestsAdvanced System Test Menus and OptionsThe graphica

Strona 9 - 2 Preparing to Run DiagTools

Chapter 3 Running DiagTools in the Graphical Mode (from Diskette)13b. To select a series of tests, highlight the item to be tested on the Main Menu. T

Strona 10

Chapter 3 Running DiagTools in the Graphical Mode (from Diskette)14About the Support TicketThe Support Ticket is a text file you can create using Diag

Strona 11

Chapter 3 Running DiagTools in the Graphical Mode (from Diskette)15down the NetServer, redo the installation, and replace all covers. Redo the system

Strona 12

iiNoticeThe information contained in this document is subject to change without notice.Hewlett-Packard makes no warranty of any kind with regard to th

Strona 14 - Running the Basic Tests

174 Running DiagTools in the Text Mode (fromthe Utility Partition)Preparation in AdvanceOnce you have completed the steps in chapter 2 under “DiagTool

Strona 15

Chapter 4 Running DiagTools in the Text Mode (from the Utility Partition)18CAUTION Before you reboot the server be sure users have been warned and net

Strona 16

Chapter 4 Running DiagTools in the Text Mode (from the Utility Partition)19and choose View Test Results.NOTE In the Misc Menu, only the Page Up and Pa

Strona 17

Chapter 4 Running DiagTools in the Text Mode (from the Utility Partition)20the screen (and in the list shown below). Use the arrow keys to highlight t

Strona 18 - To Create A Support Ticket

Chapter 4 Running DiagTools in the Text Mode (from the Utility Partition)21IDEFDD (Flexible Disk Drive)SCSIKBD (Keyboard)MiscBatchNOTE Do NOT use the

Strona 19

Chapter 4 Running DiagTools in the Text Mode (from the Utility Partition)22Verify that DiagTools correctly detected all processors and memory on the

Strona 20

Chapter 4 Running DiagTools in the Text Mode (from the Utility Partition)23Each time you create a Support Ticket, it overwrites the previous one. To p

Strona 21 - Distant Server

Chapter 4 Running DiagTools in the Text Mode (from the Utility Partition)24• If any processors, memory or SCSI devices (listed in Table 4-2) are still

Strona 22 - Main Menu in Text Mode

255 Error Message ReferenceError Messages and Their SourcesErrors are designated by a hexadecimal number. These numbers are listed in this chapter wit

Strona 23

iiiContents1 DiagTools Overview...1Introduction to Hardware Diagnos

Strona 24

Chapter 5 Error Message Reference26Code Description Recommended Actionexecution error.0007h Verify a Segment forReading) instructionexecution error.Ma

Strona 25

Chapter 5 Error Message Reference27Code Description Recommended ActionGS registers.3. Be sure the processor board (if any) is seated.4. Make sure the

Strona 26

Chapter 5 Error Message Reference28Code Description Recommended Action001Eh The detected CPUSpeed is not thesame as specified.Check jumpers or switche

Strona 27

Chapter 5 Error Message Reference29Code Description Recommended Action5. Make sure the memory elements (DIMMs) are properly seated.6. Check system fan

Strona 28

Chapter 5 Error Message Reference30Code Description Recommended Action3. Be sure the processor board (if any) is seated.4. Make sure the CPU chip is s

Strona 29 - 5 Error Message Reference

Chapter 5 Error Message Reference31Code Description Recommended Action0030h Read/Write test onDMA controller 1failed.1. Take ESD precautions and make

Strona 30

Chapter 5 Error Message Reference32Code Description Recommended Action8. If system repeatedly shows this error, replace the CPU chip or board, asappro

Strona 31

Chapter 5 Error Message Reference33Code Description Recommended Action6. Check system fans. If overheating occurs, chip may shut down.7. If the system

Strona 32

Chapter 5 Error Message Reference34Code Description Recommended Action0074h CMOS RAM time isinvalid.Run BIOS Setup if problem persists replace battery

Strona 33

Chapter 5 Error Message Reference35Code Description Recommended Action5. Make sure the CPU chip is seated. (Take ESD precautions.)6. Make sure the mem

Strona 34

ivGetting a Configuration Report...21Reviewing Results: Running the Viewers...

Strona 35

Chapter 5 Error Message Reference36Code Description Recommended Action8. If the system ran with temperature high, let it cool for 30 minutes, then res

Strona 36

Chapter 5 Error Message Reference37Code Description Recommended Actiontwice.0097h DiagTools Error Download a new version of DiagTools from the HP web

Strona 37

Chapter 5 Error Message Reference38Code Description Recommended Action2. If necessary, update the BIOS.3. Clear the CMOS and rerun configuration. See

Strona 38

Chapter 5 Error Message Reference39Code Description Recommended Action6. Be sure the processor board (if any) is seated.7. Make sure the CPU chip is s

Strona 39

Chapter 5 Error Message Reference40Code Description Recommended Actionrestart.11. If system repeatedly shows this error, replace the element with the

Strona 40

Chapter 5 Error Message Reference41Code Description Recommended Actionreference label or card.4. Make sure the system board is seated.5. Check the sea

Strona 41

Chapter 5 Error Message Reference42Code Description Recommended Action6. Check system fans. If overheating occurs, chip may shut down.7. If the system

Strona 42

Chapter 5 Error Message Reference43Code Description Recommended Action4. Make sure the CPU chip is seated.5. Make sure the memory elements (DIMMs) are

Strona 43

Chapter 5 Error Message Reference44Code Description Recommended Action0100h ROM read error. 1. Take ESD precautions and make sure the system board is

Strona 44

Chapter 5 Error Message Reference45Code Description Recommended Actiontechnical reference label or card.5. Examine the support ticket and check for fa

Strona 45

11 DiagTools OverviewIntroduction to Hardware Diagnostic ToolsThe purpose of hardware diagnostic software is to provide tools for checking serious har

Strona 46

Chapter 5 Error Message Reference46Code Description Recommended Actiontechnical reference label or card.5. Examine the support ticket and check for fa

Strona 47 - Memory Test Menu

Chapter 5 Error Message Reference47Code Description Recommended Action4. Check the positions of DIMMs to see that positioning matches that on thetechn

Strona 48

Chapter 5 Error Message Reference48Code Description Recommended Action5. Examine the support ticket and check for failures.6. Bring the system down to

Strona 49

Chapter 5 Error Message Reference49FDD (Flexible Disk Drive or Floppy) TestsFlexible Disk Drives are tested for rotational speed, elevator, and seek c

Strona 50

Chapter 5 Error Message Reference50Code Description Recommended Action0322h Floppy SpeedError.1. Try a different diskette.2. Check the cable between t

Strona 51

Chapter 5 Error Message Reference51Code Description Recommended ActionTest.3. Change the floppy drive.4. Change the system board.03FEh Diskette datare

Strona 52

Chapter 5 Error Message Reference52Code Description Recommended Action2. Replace the keyboard and rerun the test.3. Replace the system board.0413h Key

Strona 53

Chapter 5 Error Message Reference53Code Description Recommended Action4. Check for proper termination, using technical reference card or label.5. Chec

Strona 54

Chapter 5 Error Message Reference54Code Description Recommended Action4. Check for proper termination, using technical reference card or label.5. Chec

Strona 55 - KBD (Keyboard) Tests

Chapter 5 Error Message Reference55Code Description Recommended Actionget the same error, call the HP Customer Care Center.0514h DiagTools Error Downl

Strona 56 - SCSI Device Tests

Chapter 1 DiagTools Overview2DiagTools CapabilitiesDiagTools for HP NetServers is a set of off-line diagnostic tests, including tests for system and p

Strona 57

Chapter 5 Error Message Reference56Code Description Recommended Action4. Check seating of board or SCSI card.5. Check for proper termination, using te

Strona 58

Chapter 5 Error Message Reference57Code Description Recommended Action4. Check seating of board or SCSI card.5. Check for proper termination, using te

Strona 59

Chapter 5 Error Message Reference58Code Description Recommended Action0606h DiagTools Error Report error to HP Customer Care Center and get the latest

Strona 60

Chapter 5 Error Message Reference59Code Description Recommended Action0803h DiagTools Error Report error to HP Customer Care Center and get the latest

Strona 61 - Misc Tests

Chapter 5 Error Message Reference60Code Description Recommended ActionDrive x in Sector y.2. Check the cable between the CD and its controller.3. Chan

Strona 62

Chapter 5 Error Message Reference61Code Description Recommended Action4. Be sure the processor board (if any) is seated.5. Make sure the CPU chip is s

Strona 63 - IDE CD-ROM

Chapter 5 Error Message Reference62Code Description Recommended Action4. Be sure the processor board (if any) is seated.5. Make sure the CPU chip is s

Strona 64 - Multiprocessor Test

Chapter 5 Error Message Reference63Code Description Recommended Action4. Be sure the processor board (if any) is seated.5. Make sure the CPU chip is s

Strona 65

Chapter 5 Error Message Reference64Code Description Recommended Action4. Be sure the processor board (if any) is seated.5. Make sure the CPU chip is s

Strona 66

Chapter 5 Error Message Reference65Code Description Recommended ActionFailure. The patternread back from thecache is not same asthe pattern written.la

Strona 67

Chapter 1 DiagTools Overview3DiagTools User Interface Modes: Graphical or Text-BasedDiagTools has two different types of interface modes. The graphica

Strona 68

Chapter 5 Error Message Reference66Code Description Recommended Action9. If system repeatedly shows this error, replace the CPU chip or board, asappro

Strona 69

Chapter 5 Error Message Reference67Code Description Recommended Action7. Check system fans. If overheating occurs, chip may shut down.8. If the system

Strona 71

69A Test MenusBasic Test MenusNOTE DiagTools will run a different selection basic tests depending upon the type of hardwarecomponents present.Listed

Strona 72

Appendix A Test Menus70Advanced System TestsYou may select Advanced System Tests by pressing F2 after completion of Basic Tests When advanced testsare

Strona 73 - A Test Menus

71B Test DescriptionsTest DescriptionsSystem Test MenuThe tests included in the System Test Menu exercise the basic functionality of theCPU, ensuring

Strona 74 - Advanced System Tests

Appendix B Test Descriptions72 Timer TestThis test checks the accuracy of the timer count by calibrating it against theperiodic interrupt of the real

Strona 75 - B Test Descriptions

Appendix B Test Descriptions73Memory Test MenuThe Memory Test Menu includes tests that exercise all aspects of the storagemedia and key memory locatio

Strona 76 - Appendix B Test Descriptions

Appendix B Test Descriptions74Address TestThe address test writes a value in one location of memory and then scans theentire memory to find out a refl

Strona 77

Appendix B Test Descriptions75Elevator seek TestThis test verifies the track-to-track seeking capability of the floppy drive. Thistest is sometimes ca

Strona 78

Chapter 1 DiagTools Overview4• inability to indicate problems with wrongly configured systems or the network• inability to boot to systems that cannot

Strona 79

Appendix B Test Descriptions76SCSI Disk Read TestThis test reads logical blocks from the SCSI disk. If the starting logical blocknumber and end logica

Strona 80

Appendix B Test Descriptions77Serial PortA maximum of four serial ports (COM1 through COM4) are tested. Allparameters i.e. number of data bits, number

Strona 82

79C Batch MenuBatch MenuThe Batch Menu allows users to specify what tests to run as well as how manytimes to repeat a particular test.Edit Batch Param

Strona 83 - C Batch Menu

Appendix C Batch Menu80Run BatchSelecting this options is the same as pressing <F10> from the main menu. Thisoption allows you to run all of the

Strona 84 - Batch Help

81IndexAAdvanced System Testsmenus, 70Advanced System Tests, DiagTools, 11BBasic System Test, Diag Tools, 10basic testsmemory, 69miscellaneous, 69SCSI

Strona 85

52 Preparing to Run DiagToolsBegin with Simple TroubleshootingGenerally, you use DiagTools during installation to ensure that hardware components are