Hp Netserver L Server series Instrukcja Użytkownika Strona 43

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 42
Chapter 4 Installing Additional Memory
37
5. Remove the air flow guide. See Figure 4-1.
Refer to "Removing the Rear Chassis Blower/Bracket and Air Flow Guide"
in Chapter 2, "Opening and Closing the HP Netserver."
6. Locate the DIMM slots on the system board. See Figure 4-2.
7. Open the retaining latches.
8. Lift the DIMM completely away from the slot.
9. Place the DIMM in its anti-static container.
10. Repeat Steps 6-9 for as many DIMMs as you need to remove.
NOTE If you power up the HP Netserver when there are no DIMMs
installed, the screen displays an error message or appears blank
and sounds beep codes.
Przeglądanie stron 42
1 2 ... 38 39 40 41 42 43 44 45 46 47 48 ... 145 146

Komentarze do niniejszej Instrukcji

Brak uwag