Hp ProLiant DL380e Gen8 Server Instrukcja Użytkownika Strona 52

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 51
Hardware options installation 52
2.
Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Do one of the following:
o Extend the server from the rack (on page 20).
o Remove the server from the rack (on page 22).
4. Remove the access panel (on page 23).
5. Do one of the following:
o If you are installing the cache module on the system board or in a storage controller installed in the
primary PCI riser cage, remove the primary PCI riser cage ("Remove the PCI riser cages" on page
25).
o If you are installing the cache module on a storage controller installed in the optional secondary PCI
riser cage, remove the secondary PCI riser cage ("Remove the PCI riser cages" on page 25).
CAUTION: When connecting or disconnecting the capacitor pack cable, the connectors on the
cache module and cable are susceptible to damage. Avoid excessive force and use caution to
avoid damage to these connectors.
6. Connect the capacitor pack cable to the cache module.
7. When using the embedded array controller:
Przeglądanie stron 51
1 2 ... 47 48 49 50 51 52 53 54 55 56 57 ... 141 142

Komentarze do niniejszej Instrukcji

Brak uwag