High Voltage Unit Removal
7-32 Removal/Replacement Procedures
High Voltage Unit Removal
To remove the high voltage unit:
1 Open the top and back covers.
2 Remove the EMI grounding plate (if present) from the rear of the printer (four
screws).
3 From the top, loosen the screw holding the high voltage unit in place.
4 Pull the high voltage unit out from the back of the printer.
5 Disconnect connectors CN23, CN24, CN85, and the two high voltage leads.
6 Remove the high voltage unit.