cmudiff filter is <ON>, with parameters -d
cmu_pdsh>
cmu_pdsh> dmidecode
The comment now shows “(2 populations) o185i[040,042] are 83% similar”. This comment
suggests that those two compute nodes have a different BIOS release date than all other nodes.
NOTE: A nonresponsive node in the node selection for single window pdsh causes the answer
from other nodes to be delayed until a timeout occurs from the nonresponsive node. You can reduce
this delay by setting the value in the ConnectTimeout in .ssh/config variable. For example:
# vi /root/.ssh/config
Host *
StrictHostKeyChecking no
ConnectTimeout 1
6.13 Parallel distributed copy (pdcp)
The pdcp task enables you to copy a file from the HP Insight CMU administration server to multiple
nodes simultaneously.
To copy the file:
1. Right-click the nodes you want to copy to.
2. On the contextual menu, select pdcp (distributed copy). The following window opens: