HP Insight Management Agents 9.5 User
Guide
Abstract
This guide provides information about the Hewlett-Packard Insight Management Agents software, including the usage, managing,
and troubleshooting.
This guide is intended for the person who installs, administers, and troubleshoots servers and storage systems. HP assumes you
are qualified in the servicing of computer equipment and trained in recognizing hazards in products with hazardous energy
levels.
NOTE: SmartStart CD is available for installing HP Insight Management Agents software on G7 and earlier versions of the
ProLiant servers only. However, for pre-Gen8 and Gen8 ProLiant servers, HP Insight Management Agents can be installed using
the HP Service Pack for ProLiant (HP SPP).
HP Part Number: 308447-406
Published: February 2014
Edition: 1
Przeglądanie stron 0
1 2 3 4 5 6 ... 174 175

Podsumowanie treści

Strona 1 - Abstract

HP Insight Management Agents 9.5 UserGuideAbstractThis guide provides information about the Hewlett-Packard Insight Management Agents software, includ

Strona 2

IMPORTANT: For the HP Insight Management Agents to work properly, configure the followingbrowser options:• Enable Java• Enable JavaScript• Accept all

Strona 3 - Contents

number of errors is counted from the time shown in the Service Hours item in the SCSI PhysicalDrive section.Having a large number of retry corrected e

Strona 4 - 4 Contents

◦ Recovering—The logical drive is using Interim Recovery Mode. In Interim Recovery Mode,at least one physical drive has failed, but the logical drive’

Strona 5 - Contents 5

• Percent Rebuild Complete—Displays the percent complete of the resynchronization of the data.When the value reaches 100, the rebuilding process is co

Strona 6 - 6 Contents

• Physical Width—Displays the actual width of the data transfer bus for this device. The followingvalues are valid:◦ Narrow (8 bits)—The device suppor

Strona 7 - Contents 7

• SAS Logical Drive• SAS Tape Drive• SAS Storage SystemSAS Host Bus AdapterSelect a host bus adapter entry from the Mass Storage list to display the f

Strona 8 - 8 Contents

◦ Missing-Was Offline—Indicates a physical drive that was located in the system and hada status of offline has been removed.◦ Solid State Disk Wear Ou

Strona 9 - Browser requirements

• Media Type—Indicates the type of media the physical drive is composed of. The followingvalues are valid:◦ Rotating Platters—The physical drive media

Strona 10 - Obtaining JVM from Oracle

◦ Offline—The logical drive is offline and cannot be accessed by the operating system.User action may be required to bring the drive back online.◦ Unk

Strona 11 - Security

SAS Tape DriveSelect a SAS tape drive from the SAS host bus adapter sub-menu to display the followinginformation:• Model—Displays the model of the SAS

Strona 12

◦ Unknown - The Storage Agents do not recognize the status of the fan subsystem. You mayneed to upgrade your software.◦ No Fan - This storage system d

Strona 13 - Logging in

Accessing on a different operating systemsTo access Insight Management Agents from a browser running on a machine not running a MicrosoftOS, complete

Strona 14

iSCSI Storage ConnectionsSelect an iSCSI Instance entry from the Storage list to display instance and portal information anda submenu containing separ

Strona 15 - System Management Homepage

◦ IPv4z - The address is an IP version 4 address with a zone index.◦ IPv6z - The address is an IP version 6 address with a zone index.◦ DNS - The addr

Strona 16

• Number Connections displays the number of transport protocol connections that currentlybelong to this session.• Maximum R2T displays the maximum num

Strona 17 - Switch to icon view

• Protocol displays the transport protocol over which this connection is running. The followingvalues are valid:◦ IPv4 - The address is an IP version

Strona 18 - Home tab

Sub-system ClassificationPower SubsystemThis section displays information about the redundant power supplies. The following entries maybe displayed:•

Strona 19 - Overall System Health Status

• Used Capacity (%)—Represents the current power supply capacity which is a percentage ofits maximum capacity.• Used Capacity (W)—Represents the curre

Strona 20 - Version control

Temperature Sensors Information• Temperature condition—Displays the current temperature condition of the system or client PC.This value can be:◦ OK—Th

Strona 21 - Settings tab

Fault Tolerant Fans InformationThis section displays an entry for each of the device or system processor fans.• Fan—The number that uniquely specifies

Strona 22

Advanced Memory Protection (AMP)This section displays the following information about the Advanced Memory Protection sub-system.• AMP Mode Status—Disp

Strona 23

◦ Advanced ECC—You can configure the system for the Advanced ECC type of AdvancedMemory Protection.◦ Mirroring (deprecated)—You can configure the syst

Strona 24 - User Preferences

When the System Management Homepage is launched for the first time on operating systems otherthan those from Microsoft and Linux, anonymous access to

Strona 25 - Webapps tab

banks are duplicate. If more ECC errors occur, the system activates the spare memoryand disables the memory that receives the maximum errors.◦ Mirrori

Strona 26 - Event Notifier for Windows

◦ Memory RAID—The board or cartridge is configured for memory RAID mode.◦ LockStep—The board or cartridge is configured for LockStep mode.◦ LockStep M

Strona 27 - Event Notifier for Windows 27

• HP SmartMemory—Displays whether the DIMM slot is populated with an HP SmartMemoryDIMM.• Maximum Frequency—Displays memory module maximum frequency i

Strona 28 - 2 Agent information

PCI DevicesThis section displays a list of expansion boards and their associated slot numbers. You can alsoview System Resources that are used by each

Strona 29 - System Agent

Integrated Lights Out• Model—Displays the edition of the iLO in the server.• Hardware Version—Displays the Hardware revision of iLO model on the serve

Strona 30 - 30 Agent information

Reset Integrated Lights-Out (iLO)The Reset Remote Insight button is used to Reset the Remote Insight Board. Once the Remote Insightis reset, The HP In

Strona 31 - Storage agent

all warning thresholds to the highest warning threshold value. If you change one threshold, thesame threshold on all of the other volumes automaticall

Strona 32 - IDE ATA disk drives

interrupt activity. This counter displays the difference between the values observed in the lasttwo samples, divided by the duration of the sample int

Strona 33 - Storage agent 33

switches/sec rate for all threads running on all processors in the computer is measured innumbers of switches. Context switch counters on the system a

Strona 34 - IDE ATA logical drives

be compared to other counts of pages, such as Memory: Page Faults/sec, without conversion.It includes pages retrieved to satisfy faults in the file sy

Strona 35 - Array Controller Information

Deploying the configurations to servers running NetWareIn NetWare, the webagent.INI file is located in the sys:\system\cpqmgmt\webagentdirectory and s

Strona 36 - 36 Agent information

• Pool Nonpaged Bytes—Number of bytes in the nonpaged pool, an area of system memory(physical memory used by the operating system) for objects that ca

Strona 37 - Storage agent 37

Physical Disks• Volume—Name of the physical drive for which statistical information is gathered.• Queue Length—Average number of both read and write r

Strona 38 - 38 Agent information

The system processor bar graphs display the percentage of total possible system processor utilizationover the specified period of time. A bar graph is

Strona 39 - Storage agent 39

• Timeout—Displays how many minutes ASR waits before initiating a recovery process. ASRdepends on the software support to routinely notify the ASR har

Strona 40 - 40 Agent information

• USB Port Control—Prevents the transfer of data through the integrated universal serial bus(USB) port.• Floppy Disk Control—Prevents writing to the d

Strona 41 - Storage agent 41

• Socket—Displays the currently selected processor’s socket. Use this information for identificationpurposes.• Cache—Displays the amount of device or

Strona 42 - 42 Agent information

• mirrorNoFaults—The system is protected by Advanced Memory Protection in the mirroredmode. No DIMM faults have been detected.• mirrorWithFaults—The s

Strona 43 - Storage agent 43

• Board Status—This provides the current status of the Advanced Memory Protection memoryboard or cartridge. The following status values are supported:

Strona 44 - Physical Drive Information

The industry-standard addresses for serial ports are as follows:• COM1 set to 3F8h• COM2 set to 2F8hThese addresses are sometimes changed due to confl

Strona 45 - Storage agent 45

System Resources• This section lists the resources in use by the device or client workstation in the following order:• IRQ Numbers—The Interrupt Reque

Strona 46 - 46 Agent information

NOTE: The Security Alert dialog box shown is specific to Internet Explorer. However,Netscape 4.0 and later is supported as well.NOTE: If you want to i

Strona 47 - Storage agent 47

appropriate utility for your device or client) to enter a system serial number if one does notappear and you have a device or client that supports the

Strona 48 - 48 Agent information

• Load State• Input Power Type• Maximum PowerEnclosure Power Supplies• Condition• Power Supply• Serial Number• Part Number• Spare Part Number• Firmwar

Strona 49 - Spare Information

• Position (Slot Number)• Height \ Width \ Depth• Number of Bays OccupiedEnclosure Fuses• Condition• Fuse• Location• PresentEnclosure Network Connecto

Strona 50 - Predictive Indicators

◦ Processes◦ RegistryUsage◦ SystemUpTime◦ TotalThreads• CPQ_ServerAccessPermissionErrors◦◦ ContextBlockQueueRate◦ GrantedAccessErrors◦ LogonErrors◦ Se

Strona 51 - Problem Indicators

• CPQ_PagingFilePageFileUsagePercent◦◦ PagingFile• CPQ_CacheCopyReadHitsPercent◦◦ CopyReadRate• CPQ_PhysicalDiskCurrentDiskQueueLength◦◦ DiskBytesPers

Strona 52 - Failure Indicators

◦ PacketsSentPersec◦ TotalByteRate• CPQ_Tcp (CPQ_Tcpv4 for Windows Server 2003)ConnectionFailures◦◦ ConnectionsActive◦ ConnectionsEstablished◦ Segment

Strona 53 - Statistics

The following list describes errors that might be logged. If any of these errors occur, run SystemDiagnostics on the system or see the software docume

Strona 54 - 54 Agent information

• NMI-Processor Internal Error 1—A processor internal parity error occurred, resulting in adevice failure.• NMI-Processor Internal Error 2—The process

Strona 55 - Storage agent 55

To clear a degraded or failed event log, repair the condition that caused a log entry to begenerated, and then mark the log entry as repaired. Perform

Strona 56 - 56 Agent information

3 Subsystem specific to a NetWare operating systemOperating system overviewHP now provides operating system management for NetWare environments. The N

Strona 57 - Storage agent 57

NOTE: If you have enabled anonymous access, then you can access the System ManagementHomepage displays without asking for any credentials locally.NOTE

Strona 58 - 58 Agent information

• System Time—The date and time kept by this server.• Up Time—The time (in hundredths of a second) since this server was last restarted.• User Count—T

Strona 59 - Storage agent 59

User Information pageThe User Information page lists all user accounts in this file server. Users in the table might or mightnot be logged in at the t

Strona 60 - 60 Agent information

Table 3-4 Available status conditionsAudit connection recordedNeed security changeDS audit connection recordedMacStationLogout in progressConnection a

Strona 61 - Tape Drive Information

• TimeOffset—In the format of +/- XX:XX:XX (hour:minute:second). To do a set, modify the valuein the predefined format in the text field, and click SE

Strona 62 - 62 Agent information

4 CR3500 RAID Array SCSI controllerMass storage RAID ArrayThis section displays RAID array information. Five banners appear in this section.RAID array

Strona 63 - Storage agent 63

Physical Drive status• The following conditions are valid:• On Line—The drive attached to this channel is a fully-functional member of this RAID set.•

Strona 64 - Storage Systems

I/O response over the RAID set creation. A rate above 50 puts a higher priority on the RAIDset creation at the expense of I/O activity.• Cache Size—Di

Strona 65 - Storage agent 65

External Expansion CabinetThis section displays the External Expansion Cabinet information. The following conditions arevalid:• Power Supply Status—Di

Strona 66 - 66 Agent information

5 Support and other resourcesInformation to collect before contacting HPBe sure to have the following information available before you contact HP:• So

Strona 67 - Storage System Information

The service also provides access to software updates and reference manuals in electronic form asthey are made available from HP.With this service, Ins

Strona 68 - 68 Agent information

• Management processor – Integrated Lights Out• Data source• Switch to List view• Switch to Icon view• Legend• RefreshUserThe User field displays the

Strona 69 - Storage agent 69

Ctrl+x or Ctrl-x A key sequence that indicates you must hold down the keyboardkey labeled Ctrl while you press the letter x.ENVIRONMENT VARIABLE The n

Strona 70 - 70 Agent information

6 Documentation feedbackHP is committed to providing documentation that meets your needs. To help us improve thedocumentation, send any errors, sugges

Strona 71 - Storage agent 71

A TroubleshootingInsight Management Agents for servers issuesInability to perform remote reboot on a server from the Management Console1. Load CPQAGIN

Strona 72 - 72 Agent information

1. Select Edit Preferences⇒Advanced (expand)⇒Cache.2. Under the Compare the page in the cache to the page on the network heading, select theevery time

Strona 73

• Frame sizes are optimized for medium-sized fonts. If you switch your browser to use larger orsmaller fonts, then you must manually adjust the frame

Strona 74 - 74 Agent information

IMPORTANT: For Windows Server 2003, Windows 2000, Windows NT, NetWare 5.1,and NetWare 6.0 (SNMP Only), enter the Monitor and Control community strings

Strona 75 - Accelerator Information

under Configure SNMP Service. The Insight Manager community string is set in the DeviceSetup window from the management console (select Device Setup f

Strona 76 - 76 Agent information

Load the device driver using one of the following methods:• If an HP SCSI controller is installed in the monitored system, load the correct device dri

Strona 77 - Storage agent 77

Problems if the address 127.0.0.1 is not added to SNMP host listThe following problems occur only if the address 127.0.0.1 is not added to the SNMP ho

Strona 78

1. Select Operation⇒Hardware Setup.2. Re-select the tape drive to use. If these actions do not eliminate the error message, the tapedrive might not be

Strona 79 - Storage agent 79

Figure 4 System Management Homepage — List ViewSwitch to icon viewDisplays the System Management Homepage contents as folder icons.Figure 5 System Man

Strona 80 - 80 Agent information

Identifier when HP Systems Insight Manager performs an SNMP SET command to the NetWareserver.1. To remove the permanence of the Global Unique Identifi

Strona 81 - Logical Drive Information

5. Uncheck the Automatically Restart check box.6. Click OK.Insight Management Agents for servers issues 171

Strona 82 - 82 Agent information

GlossaryThis Glossary provides the list of all the glossary terms and their definitions.Automatic ServerRecovery (ASR)A server feature designed to aut

Strona 83 - Snapshot Resource Volumes

Simple NetworkManagementProtocol (SNMP)SNMP defines a set of commands that a management application uses to retrieve or change thevalues of items a ma

Strona 84 - 84 Agent information

IndexAaccountsuser, 11Adapter Information Page, 153array controllers, 20ASR POST failure, 168authorized resellers, 158Bbrowserrequirements, 9CClient d

Strona 85 - Storage agent 85

typographic conventions, 159Uupdate serviceregistering, 158User Information Page, 151Vvaluesinability to change,, 169Wwarranty, 158Web-enabled Managem

Strona 86 - External Storage Connections

Figure 6 System Management Homepage — Status IconsRefreshClick on the Refresh link to refresh the System Management Homepage.Body frameThe body of the

Strona 87 - Storage agent 87

• System Configuration• Version ControlFigure 7 System Management Homepage — Home tabOverall System Health StatusThe Overall System Health Status disp

Strona 88 - Controller information

© Copyright 2002, 2014 Hewlett-Packard Development Company, L.P.The information contained herein is subject to change without notice. The only warrant

Strona 89 - SCSI device information

The window also displays information about the following NIC components:• Embedded NIC• Integrated Lights-Out NICNICThe NIC displays information about

Strona 90 - Tape library

Settings tabThe Settings tab provides you with the ability to access the agent options and define theManagement HTTP Server security settings.Figure 8

Strona 91 - Storage agent 91

Figure 10 System Management Homepage — SNMP & Agent Settings pageIf you make Management Agents Configuration changes, you must click the Restart A

Strona 92 - Tape devices

SecurityProvides following options and also contains notes which describe the usage of the each of theoption available and also procedure to set the v

Strona 93 - Storage agent 93

are considered less secure than certificate based trust modes. The following are the securityoptions in the Trust Mode:◦ Trust by Certificate—Sets HP

Strona 94 - CD storage system

Tasks tabThe Tasks tab displays links to task-oriented pages provided by participating HP Web-EnabledSystem Management software.NOTE: If the HP Web-En

Strona 95 - Storage systems

Figure 13 System Management Homepage — Webapps tabSupport tabThe Support tab contains of links to available support services like – ProLiant Essential

Strona 96 - SCSI physical drives

The wizard displays the following three screens to guide you easily through the process:• Welcome to the HP Event Notifier Configuration Wizard• Mail

Strona 97 - Storage agent 97

2 Agent informationManagement Host agentThe Management Host agent gathers data for the HP Host OS MIB. This data includes:• Server/host name and OS ve

Strona 98 - Drive indicators

Threshold AgentThe Threshold Agent is designed to provide support for HP Insight Manager user-defined thresholds.It also provides a generic way to set

Strona 99 - Drive statistics

Contents1 HP Insight Management Agents for servers...9Browser requirements ...

Strona 100 - SCSI logical drives

Cluster resources groupsThe Cluster Resources Groups section displays the cluster resources by resource group. The followinginformation might appear:•

Strona 101 - Storage agent 101

• Address Mask—Displays the address mask used by the network in the format specified by thetransport type.• Description—Displays the text network desc

Strona 102 - SCSI bus information

Agents might need to be updated. Select any of the devices from the submenu to display moreinformation about the devices. The following information di

Strona 103 - Storage agent 103

◦ Failed—The disk drive has failed and must be replaced.◦ Unknown—The Storage Agents cannot determine the status of the disk drive. You mightneed to u

Strona 104 - SAS Host Bus Adapter

• Disk Type—Indicates the type of disk drive. The following values are valid:ATA—The disk is a parallel ATA disk drive.◦◦ SATA—The disk is a Serial AT

Strona 105 - Storage agent 105

◦ Rebuilding—Indicates that the logical drive is rebuilding a physical drive. When complete,the logical drive returns to normal operation.◦ Failed—Ind

Strona 106 - SAS Logical Drive

The following information displays for each controller:• Model—Displays the type of controller card.• Controller Status—Displays the array controller

Strona 107 - Storage agent 107

◦ Different Firmware—The other controller indicates a different firmware version.◦ Different Cache—The other controller indicates a different cache si

Strona 108 - SAS Storage System

• Daughter Board Type—Displays the type of daughter board installed on the array controller.The following values are valid:◦ Not Supported—Indicates t

Strona 109 - Storage agent 109

◦ RAID Stack Version—lists the RAID stack version operating the B-series array controller.This value may change when upgrading or downgrading the oper

Strona 110 - 110 Agent information

User Preferences...24Tasks tab...

Strona 111 - Session Information

◦ Unavailable—An Cache Module has not been configured.◦ Unknown—The Storage Agents cannot determine the status of the Cache Module. Youmay need to upg

Strona 112 - Connect Information

• Error Code—Displays the status of the cache operations. The following values are valid:None—Cache operations are currently configured and enabled fo

Strona 113 - Storage agent 113

◦ Redundant Low Battery—Cache operations are temporarily disabled. The redundantcontroller has insufficient cache battery power.◦ Redundant Size Misma

Strona 114 - Sub-system Classification

◦ Flash Backed Cache Capacitor Failed To Charge—Indicates that write cache operationshave been permanently disabled. The cache has been disabled becau

Strona 115 - System Information

an image of an identified drive and a Stop button. Click the Stop button to end identification beforethe time expires.After the drive identification c

Strona 116 - 116 Agent information

◦ Not Authenticated—The physical drive could not be authenticated as a genuine HP harddrive. The array controller will no longer control the drive LED

Strona 117 - Sub-system Classification 117

• S.M.A.R.T. Support—Indicates whether or not the SCSI physical drive supports S.M.A.R.T. Thepossible values are:◦ Available—This drive supports predi

Strona 118 - 118 Agent information

• Drive Type—Indicates the type of physical drive. The following values are valid:SCSI—The physical drive is a parallel SCSI drive.◦◦ SATA—The physica

Strona 119 - Sub-system Classification 119

◦ Not Redundant—Indicates that the physical drive previously had more than one I/O pathto the controller but now has no redundant I/O path.◦ Disk Fail

Strona 120 - Memory Summary

Identify DriveSelect the length of time to identify the physical drive from the drop-down list box and then clickthe Start button. The page automatica

Strona 121 - Memory Details

Backplane Information...71Asset Information...

Strona 122 - 122 Agent information

Predictive IndicatorsUse the Predictive Indicators to predict when a drive, which is now operating normally, may needto be replaced.• S.M.A.R.T. Statu

Strona 123 - Sub-system Classification 123

Problem IndicatorsUse the Problem Indicators to determine when a drive failure has occurred that may be correctablewithout replacing the drive. The Pr

Strona 124 - Integrated Lights Out

1. Ensure that all system and storage system cables are intact and seated properly. You mayneed to replace cables.2. Check the physical proximity of t

Strona 125 - Operating System

• Hardware Errors—The Hardware Errors counter records the number of times that a physicalSCSI drive returned a Hardware Error status when a SCSI comma

Strona 126 - Processors

• Recovered Read Errors—Displays the number of read errors corrected through physical driveretries. Over time, all drives produce these errors. If you

Strona 127 - Sub-system Classification 127

◦ Ready rebuild—Indicates that the logical drive is ready for Automatic Data Recovery. Thephysical drive that failed has been replaced, but the logica

Strona 128 - 128 Agent information

When the status is Rebuilding one of the following values displays to indicate the progress ofthe rebuild:◦ Percent Rebuild Complete—Displays the perc

Strona 129 - Sub-system Classification 129

◦ RAID 60—Advanced data guarding (RAID 6) with multiple parity groups.◦ RAID 1 (ADM) - Advanced Data Mirroring—For each physical drive, there are two

Strona 130 - 130 Agent information

• Caching Algorithm displays the caching algorithm currently in use for the cache volume. Thefollowing values are valid:◦ Unknown—Indicates that the S

Strona 131 - Processor Utilization

Identify Drive1. Select the length of time to identify the physical drives that make up the logical drive from thedrop-down list box, and then click t

Strona 132 - Auto Recovery

Session Statistics Information...112Associated iSCSI Connections ...

Strona 133

Tape Storage System InformationSelect the Tape Storage System Information entry from the Mass Storage submenu to display thefollowing information.• St

Strona 134 - System Board

◦ Ultra3—The current data transfer speed for this tape library is 80 million transfers persecond.◦ Unknown—The agent is unable to determine the curren

Strona 135 - Sub-system Classification 135

◦ Missing - Was Offline—Indicates that a tape drive that was located in a system and hada status of offline has been removed.◦ Unknown—Indicates that

Strona 136 - 136 Agent information

• Negotiated Link Rate—Displays the negotiated link rate for SAS and SATA tape drives. Thepossible values are:◦ 1.5 Gbps—The negotiated link rate for

Strona 137 - Sub-system Classification 137

• Rewrites—Displays the number of times blocks that had to be rewritten to the device. Thisvalue is maintained since the Tape Hardware Interface drive

Strona 138 - 138 Agent information

• Fan Status—Displays the status of the fan subsystem in the drive enclosure, or box. The followingvalues are possible:◦ OK—The fan subsystem is worki

Strona 139 - System Summary

• Side Panel—Displays the status of the side panel of the drive enclosure, or box. The followingvalues are possible:◦ In Place—The side panel is close

Strona 140 - Enclosure Information

External Array Storage SystemsThis section displays general and status information about external array storage systems. Selectan external array stora

Strona 141 - Server Enclosure

• IO Module Type displays the storage system chassis SCSI I/O module type that is installed.The following values are possible:◦ 2 Port Ultra3 SCSI Mod

Strona 142 - ◦ CpqQueueLength

◦ EV Timeout Error - The recovery server option environment variable, that contains thestatus, cannot be accessed. The attempted access timed out.◦ Un

Strona 143 - Sub-system Classification 143

Serial and Parallel Ports...137Universal Serial Bus Port...

Strona 144 - 144 Agent information

◦ Not Supported - This storage system does not support reporting fan status through thisstorage system backplane. The fan status is reported through t

Strona 145 - Sub-system Classification 145

◦ Not Redundant (Power Supply 2 Missing) - This storage system does not have a redundantpower supply. The power supply in bay 2 is missing.◦ Not Suppo

Strona 146 - 146 Agent information

◦ Power Supplies - This is a composite of all the installed power supplies.◦ Unknown - The Storage Agents do not recognize the bay. You may need to up

Strona 147 - Integrated Management Log

◦ Fans - This is a composite of all the installed fan modules.◦ Unknown - The Storage Agents are unable to determine the location of this storage syst

Strona 148 - 148 Agent information

◦ High - indicates the expand priority is high.◦ Unknown - indicates that the expand priority is not recognized. You may need to upgradethe Storage Ag

Strona 149 - Summary page

◦ Other No Drives - This controller can see the attached drives, but the other controllercannot.◦ Unsupported Drives - One or more attached drives has

Strona 150 - File System page

• Read Errors displays the total number of read memory parity errors that were detected whilereading from the Array Accelerator. If a memory parity er

Strona 151 - Connection page

the system is first powered up, the board performs a data compare test between themirrored copies. If the data does not match, an error has occurred.

Strona 152 - Server Parameter page

When there are redundant controllers only the active controller can be used to identify the drivesconnected to the controller.IMPORTANT: The Start or

Strona 153 - Adapter Information page

• Serial Number displays the serial number assigned to the physical drive. This value is basedupon the serial number as returned by the SCSI inquiry c

Strona 154 - Mass Storage Physical

5 Support and other resources...158Information to collect before contacting HP...

Strona 155 - Mass Storage controller

• Placement indicates whether the physical drive is in an internal or external storage system.The following values are valid:◦ Internal - The physical

Strona 156 - Environment Monitoring Unit

Logical Drive InformationA list of logical drives associated with the controller displays in the Mass Storage submenu. Eachlogical drive in the list d

Strona 157 - External Expansion Cabinet

• Fault Tolerance displays the fault tolerance mode of the logical drive. To change the faulttolerance mode, run the System Configuration Utility.The

Strona 158 - 5 Support and other resources

Identify DriveSelect the length of time to identify the physical drives that make up the logical drive from thedrop-down list box and then select the

Strona 159 - Typographic conventions

◦ Resource Volume Disconnected - The snapshot resource volume has been disconnectedfrom the source volume.◦ Source Volume Not Located - The source vol

Strona 160

• Mounted indicates if the snapshot is currently mounted. The following values are valid:Mounted - The snapshot is currently mounted.◦◦ Not Mounted -

Strona 161 - 6 Documentation feedback

• Subnet Mask displays the IP subnet mask of the switch.• Gateway Address displays the gateway IP address of the switch.• Manage Switch is a link to t

Strona 162 - A Troubleshooting

◦ Not Connected - Indicates that the fibre channel port is not connected or the device towhich it is connected is powered down.◦ Unknown - Indicates t

Strona 163 - Known browser issues

• Controller Bus displays the array controller's bus number for the connection to this storagesystem.• The condition of the connection path, the

Strona 164 - SNMP community string issues

◦ The StorageWorks Library Adapter◦ Third-party SCSI Controller Model◦ Unknown—The driver software or storage agents might need to be upgraded, or you

Strona 165 - Insight Manager issues

1 HP Insight Management Agents for serversThe HP System Management Homepage version 8.25 and later acts as the Web server for theManagement Agents. Fo

Strona 166 - Missing NIC information

The following information is a list of device types and the information displayed for all SCSI devices:• Device Type—Identifies the type of SCSI devic

Strona 167

• Serial Number—Displays the unit serial number for the library. It can be used for identificationpurposes.• Firmware Version—Displays the firmware re

Strona 168 - Other problems

◦ Not supported—Indicates that the library cannot detect or report hot-swap status.◦ Unknown—The hot-swap status of the tape library cannot be determi

Strona 169

• Library Drive—Indicates whether the tape drive is included in a tape library. The followingvalues are valid:◦ Yes—The tape drive is included in a ta

Strona 170 - 170 Troubleshooting

• Cleaning Tape Needs Replacement—Indicates the cleaning tape associated with the autoloaderis at the end of the tape. If the cleaning tape is at the

Strona 171 - 6. Click OK

Storage systemsSelect a storage system item from the SCSI controller submenu to display the following informationabout ProLiant Storage Systems.• Box

Strona 172 - Glossary

• Backplane Speed—Displays the speed of the storage system backplane. The following valuesare possible:◦ Ultra3—The storage system is capable of Ultra

Strona 173

◦ Missing was Failed—A physical drive that was located in the system and had a status offailed has been removed.◦ Missing was Predictive Failure—A phy

Strona 174 - 174 Index

Drive indicatorsSelect a SCSI physical drive from the SCSI controller submenu to display information on actionsto take when a SCSI physical drive is n

Strona 175

• Failure Indicator—Use this utility to determine the cause of failure for a failed drive. If the drivehas failed and this counter is non-zero, replac