Sub-system Classification
Power Subsystem
This section displays information about the redundant power supplies. The following entries may
be displayed:
Location—Displays the bay where the power supply is located.
Condition—Displays the status of the power supply. The following values are possible:
OK—A power supply is installed and operating normally.
Failed—A power supply is installed and is no longer operating. Replace the power supply.
Not Installed—Nothing is installed in this power supply bay.
Unknown—The Server Agent is unable to determine if this storage system power supply
bay is occupied.
Serial Number—Displays the serial number of the power supply. This information can be used
for identification purposes.
Firmware Revision—Displays the firmware revision of the power supply.
Present—Represents whether the power supply is present in the chassis.
Status—Represents the status of the power supply in the chassis. The following values are
possible:
No Error
General Failure
Bist Failure
Fan Failure
Temperature Failure
Interlock Open
EPROM Failed
VREF Failed
DAC Failed
RAM Test Failed
Voltage Channel Failed
Orring Diode Failed
Brownout
Give Up On Startup
NVRAM Invalid
Calibration Table Invalid
If the power supply is absent, the status is "Not Applicable"