Toolkit utilities 39
CONREP –l (Load from Data File) Example Usage for HP
ProLiant 100 series servers
To load the BIOS configuration settings from a previously captured/edited data file (in this case
“sl160zconrep.dat”) to an SL160z G6 server:
[root@ilo002481b08134 conrep]# ./conrep -l -xconrepSL160zg6_20090728.xml -fsl160zconrep.dat
conrep 3.00 - SmartStart Scripting Toolkit Configuration Replication Program
Copyright (c) 2007-2009 Hewlett-Packard Development Company, L.P.
System Type: ProLiant SL160z G6
ROM Date : 07/28/2009
ROM Family : O33
Processor Manufacturer : Intel
XML System Configuration : conrep_SL160zg6_20090728.xml
Hardware Configuration : sl160zconrep.dat
Loading configuration from sl160zconrep.dat.
ASM values not set! aborting
CONREP Return code: 0
NOTE: The "ASM values not set! aborting" message shown in the output above is a spurious
error message meant only for 300-series and above ProLiant systems. It should be ignored if
seen on an HP ProLiant 100-series server.
CONREP Data File Sample Contents for HP ProLiant 100 series
servers
A typical data file generated by CONREP is similar to the following:
<Conrep_data>
<Section name="Controller_Order">
<Id0>0e 11 40 80 </Id0>
<Slot0>00 </Slot0>
<BusDev0>00 08 </BusDev0>
<Rest0>01 </Rest0>
<Id1>0e 11 ff ff </Id1>
<Slot1>00 </Slot1>
<BusDev1>00 78 </BusDev1>
<Rest1>c1 </Rest1>
/Section>
<Section name="Language">ENGUSAus </Section>
<Section name="System_WOL">Disabled</Section>