Przeglądanie stron 107
Single-Ended I/O Module
5–6 UltraSCSI RAID Enclosure
Only when all I/O modules are the same type can an UltraSCSI RAID
subsystem function properly. The Compaq UltraSCSI controller only
supports single-ended buses. Therefore, use only single-ended I/O
modules (DS–BA35X–MN). The enclosure does not support the
following conditions:
Improperly installing a single-ended I/O module
Installing fewer than six single-ended I/O modules
Installing a termination I/O module
Installing a differential I/O module
TERMPOWER Errors
The I/O module displays a TERMPOWER status indication for both
the internal and external bus as shown in Figure 5–4.
Figure 54 I/O Module TERMPOWER LEDs
The nominal TERMPOWER for both buses is +5 V dc.
The green internal (C
ALLOUT 2) and external (CALLOUT 1)
TERMPOWER LEDs are ON during normal operation.
If a TERMPOWER overcurrent condition exists or there is no
TERMPOWER, the associated LED is O
FF.
Figure C
ALLOUTS
1. External
TERMPOWER
2. Internal
TERMPOWER
CXO5829B