5. Enter the settings for the management port.
NOTE:
Port State must be
Enabled
(default) to use the SMU. If the management port state was
disabled,youmustusetheCommandLineInterface(CLI)tore-enableit.(Formore
information, see the Command Line Interface user guide.)
•AssignaHost Name to the storage system (default: chassis serial number). HP
recommends changing this to a more helpful user-dened value.
Port Name MA0 is the default management port. Although other ports can be
congured as the primary management port, HP recommends conguring and using
the default.
To control the path of management trafc to and from the array controller and to
add one level of system security, HP recommends assigning a static IP address to the
management port that is in a different LAN segment than the data ports. To assign
a static IP address, expand the DHCP Setting drop-down box and change the setting
to Disabled. The page expands (shown), showing the currently assigned IP address.
Change this to the address you want to use for management trafc. After changing the
IP address, you may need to re-connect to the SMU using the newly assigned IP address.
•Bydefault,VLAN ID is 0, meaning that trafc owing from the port to the switch will be
untagged.ToassignaVLANforthisporttouse,enteritsvalue.VLANsaresetupon
theswitch,andareusedasonemethodofcontrollingaccesstothestoragesystem.
IMPORTANT:
For dual-controller congurations, repeat these steps to congure the management port on the other
controller.
The default management port for controller A is MA0.
The default management port for controller B is MB0.
Conguring data ports
Conguring each data port includes two steps:
Assigning one or more IP addresses to the port (Step 1).
Assigning one or more TCP portals to each IP address (Step 4).
IMPORTANT:
Congure all data ports you plan to use, including ports on the Ethernet iSCSI module associated
with the controller in slot 2, if installed.
HP Storage Management Utility user guide
35