Hp Surestore Disk Array 12h and FC60 Instrukcja Użytkownika Strona 1

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Przechowywanie Hp Surestore Disk Array 12h and FC60. HP Surestore Disk Array 12h and FC60 User Manual [en] Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 0
This manual was downloaded from http://www.hp.com/support/fc60/
HP SureStore E Disk Array FC60
Advanced User’s Guide
Edition E1200
Printed in U.S.A.
hpHH
Przeglądanie stron 0
1 2 3 4 5 6 ... 465 466

Podsumowanie treści

Strona 1 - Advanced User’s Guide

This manual was downloaded from http://www.hp.com/support/fc60/HP SureStore E Disk Array FC60Advanced User’s GuideEdition E1200 Printed in U.S.A.hpHH

Strona 2 - Safety Notices

10 Attaching Power Cords . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .183Attaching SCSI Cable

Strona 3 - Printing History

100 Recommended Disk Array ConfigurationsTotal Disk Array CapacityThe total capacity provided by the disk array depends on the number and capac

Strona 4 - Manual Revision History

For high-availability, one disk per SCSI channel is used as a global hot spare. 101Topology and Array PlanningFor high-availability, one disk pe

Strona 5 - About This Book

102 Topologies for HP-UXTopologies for HP-UXThe topology of a network or a Fibre Channel Arbitrated Loop (Fibre Channel-AL) is the physical lay

Strona 6

Topologies for HP-UX 103Topology and Array PlanningBasic TopologyThe basic topology covers a number of physical implementations of host systems

Strona 7 - 1 Product Description

104 Topologies for HP-UXFor high availability the hosts and disk arrays can be connected in any of the following ways, with each connection of

Strona 8 - 2 Topology and Array Planning

Topologies for HP-UX 105Topology and Array Planning Figure 35Basic Topology, High Availability Version: Host with Two Fibre Channel I/O Adapters

Strona 9 - 3Installation

106 Topologies for HP-UXFigure 36Basic Topology, High Availability Version: Host with Four Fibre Channel I/O AdaptersThe non-high availability

Strona 10 - 10

Topologies for HP-UX 107Topology and Array Planningcontroller modules in four disk arrays. Each connection between adapter and controller module

Strona 11 - Contents

108 Topologies for HP-UXTable 8 Basic Topology Error RecoveryFailing componentContinue after failure What happens and how to recoverDisk modul

Strona 12 - 5 HP-UX Diagnostic Tools

Topologies for HP-UX 109Topology and Array PlanningFibre Channel cableNo on path to failed cable;Yes if array has dual controller modules and al

Strona 13 - 7 Removal and Replacement

11Contents4 Managing the Disk Array on HP-UXTools for Managing the Disk Array FC60. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 14 - 14

110 Topologies for HP-UXSingle-System Distance TopologyEach instance of the single-system distance topology generally uses the following hardwa

Strona 15 - 15

Topologies for HP-UX 111Topology and Array Planningchapter for part numbers). Fibre optic cables longer than 100 m must be custom-fabricated for

Strona 16 - 16

112 Topologies for HP-UXFigure 38 illustrates the single-system distance topology with one host with two Fibre Channel I/O adapters and three d

Strona 17 - 1 PRODUCT DESCRIPTION

Topologies for HP-UX 113Topology and Array PlanningTable 9 Single-System Distance Topology Error RecoveryFailing componentContinue after failur

Strona 18 - Product Description

114 Topologies for HP-UXFibre Channel I/O adapterNo on path to failed adapter; Yes if array has dual controller modules and alternate paths hav

Strona 19 - Array Controller FC60

Topologies for HP-UX 115Topology and Array PlanningHigh Availability TopologyThe high availability topology increases the availability of the si

Strona 20 - Features

116 Topologies for HP-UXBecause each HP Fibre Channel-AL Hub has ten ports, either two host adapters and eight controller modules or four host

Strona 21 - Scalable Storage Capacity

Topologies for HP-UX 117Topology and Array PlanningFigure 39High Availability Topology

Strona 22 - LED Status Monitoring

118 Topologies for HP-UXTable 10 High Availability Topology Error RecoveryFailing componentContinue after failure What happens and how to reco

Strona 23 - Disk Enclosure Components

Topologies for HP-UX 119Topology and Array PlanningFibre Channel cableNo on path to failed cable;Yes if array has dual controller modules and al

Strona 24 - Figure 2

12 Managing the Disk Array Using Array Manager 60. . . . . . . . . . . . . . . . . . . . . . . . . .276Command Syntax Conventions. . . . . . .

Strona 25 - Operation Features

120 Topologies for HP-UXHigh Availability, Distance, and Capacity TopologyThe high availability, distance, and capacity topology expands on the

Strona 26 - Power Switch

Topologies for HP-UX 121Topology and Array PlanningSupported cable lengths for each segment of the Fibre Channel-AL include 2 m, 16 m, 50 m, 100

Strona 27 - Disk Enclosure SC10 Modules

122 Topologies for HP-UXFigure 40High Availability, Distance, and Capacity Topology

Strona 28

Topologies for HP-UX 123Topology and Array Planning Table 11 High Availability, Distance, and Capacity Topology Error RecoveryFailing component

Strona 29

124 Topologies for HP-UXFibre Channel cableNo on path to failed cable;Yes if array has dual controller modules and alternate paths have been co

Strona 30

Topologies for HP-UX 125Topology and Array PlanningCampus TopologyThe campus topology uses the same hardware components as the high availability

Strona 31

126 Topologies for HP-UX Figure 41Campus Topology

Strona 32 - Power Supplies

Topologies for HP-UX 127Topology and Array PlanningTable 12 Campus Topology Error Recovery Failing componentContinue after failure What happen

Strona 33

128 Topologies for HP-UXFibre Channel cableNo on path to failed cable;Yes if array has dual controller modules and alternate paths have been co

Strona 34

Topologies for HP-UX 129Topology and Array PlanningPerformance Topology with SwitchesPrevious topologies use Fibre Channel HUBs for interconnect

Strona 35

13ContentsSupport Tools Manager . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .347STM User Inte

Strona 36 - Figure 9

130 Topologies for HP-UXFigure 43Four Hosts Connected to Cascaded Switches

Strona 37 - Front Cover

Topologies for Windows NT and Windows 2000 131Topology and Array PlanningTopologies for Windows NT and Windows 2000The topology of a network or

Strona 38 - Controller Modules

132 Topologies for Windows NT and Windows 2000Figure 44An Unsupported Single-Hub TopologyUnsupported Windows TopologyBecause this topology prov

Strona 39 - Controller Module LEDs

Topologies for Windows NT and Windows 2000 133Topology and Array PlanningNon-High Availability TopologiesFigure 45 through Figure 47 illustrate

Strona 40 - Controller Fan Modules

134 Topologies for Windows NT and Windows 2000Figure 45Four Host/Single Hub/ Single Disk Array Non-HA Topology

Strona 41 - Figure 13

Topologies for Windows NT and Windows 2000 135Topology and Array PlanningFigure 46Four Host/Cascaded Hubs/ Dual Disk Array Non-HA Topology

Strona 42 - Power Supply Modules

136 Topologies for Windows NT and Windows 2000Figure 47Four Host/Single Switch/ Dual Disk Array Non-HA Topology

Strona 43 - Power Supply Fan Module

Topologies for Windows NT and Windows 2000 137Topology and Array PlanningHigh Availability TopologiesFigure 48 through Figure 51 illustrate high

Strona 44 - Figure 15

138 Topologies for Windows NT and Windows 2000Figure 48Direct Connect Single Host/Single Disk Array HA Topology

Strona 45 - Battery Backup Unit

Topologies for Windows NT and Windows 2000 139Topology and Array PlanningFigure 49Dual Host/Dual Hub/Four Disk Array HA Topology

Strona 46

14 Disk Enclosure Fan Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .392Disk Enclosure Power Supply M

Strona 47 - Disk Mirroring

140 Topologies for Windows NT and Windows 2000Figure 50Four Host/Dual Hub/Dual Disk Array HA Topology

Strona 48 - Data Parity

Topologies for Windows NT and Windows 2000 141Topology and Array PlanningFigure 51Four Host/Dual Cascaded-Hubs/Four Disk Array HA Topology

Strona 49 - Data Striping

142 Topologies for Windows NT and Windows 2000

Strona 50 - RAID Levels

Installation1433INSTALLATIONHost System Requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145Site

Strona 51

144 OverviewOverview This chapter explains how to install the Disk Array FC60 enclosures into a cabinet and how to configure and connect the co

Strona 52 - RAID 0/1

Host System Requirements 145InstallationHost System RequirementsHP-UXThe Disk Array FC60 is supported on the following host configurations:•Supp

Strona 53

146 Host System RequirementsFibre Channel I/O AdaptersThe host must have the correct adapter installed. The supported host adapters are listed

Strona 54

Site Requirements 147InstallationSite RequirementsEnvironmental RequirementsThe area around the array must be cooled sufficiently so it does not

Strona 55

148 Site Requirements * In-rush current occurs for 10 to 12 milliseconds Table 14 Total Operating and In-Rush Currents Oper

Strona 56

Site Requirements 149Installation * In-rush current occurs for 10 to 12 millisecondsHP recommends the use of magnetic-type circuit breakers, wh

Strona 57 - RAID Level Comparisons

15ContentsAC Power:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .425DC Power

Strona 58 - Table 3

150 Power Distribution Units (PDU/PDRU)Power Distribution Units (PDU/PDRU)PDUs provide a sufficient number of receptacles for a large number of

Strona 59 - Table 4

Power Distribution Units (PDU/PDRU) 151InstallationThe following tables show recommended PDU/PDRU combinations for one or more components in a r

Strona 60 - Table 5

152 Power Distribution Units (PDU/PDRU)Installing PDUs Choose PDU/PDRU locations with the following guidelines in mind:•Place PDU/PDRUs within

Strona 61 - Global Hot Spare Disks

Power Distribution Units (PDU/PDRU) 153Installation Figure 52PDU Placement in 1.6-Meter RackPDU 16 Amp or PDRU 30 AmpPDU 16 Amp or PDRU 30 Am

Strona 62

154 Power Distribution Units (PDU/PDRU) Figure 53PDRU Placement in 2.0-Meter RackPDU (16 Amp)or PDRU (30 Amp)PDU (16 Amp) or PDRU (30 Amp)

Strona 63 - Figure 23

Installing the Disk Array FC60 155InstallationInstalling the Disk Array FC60NoteThe A5277AZ factory assembled disk array is fully configured and

Strona 64

156 Installing the Disk Array FC60Table 21 EIA Spacing for Racks and Array Enclosures NoteIMPORTANT: When installing an enclosure in a rack, i

Strona 65 - Capacity Management Features

Installing the Disk Array FC60 157Installationinstallation to utilize 1/2 EIA units available from the disk system SC10’s 3.5 EIA unit height.Fi

Strona 66 - Disk Array Caching

158 Installing the Disk Array FC60 Figure 54Enclosure EIA Positions for System/E Racks

Strona 67 - Dynamic Capacity Expansion

Installing the Disk Array FC60 159Installation Figure 55Enclosure EIA Positions for Legacy Cabinets

Strona 69 - 2 TOPOLOGY AND ARRAY PLANNING

160 Installing the Disk EnclosuresInstalling the Disk Enclosures Disk enclosures should be installed in the rack starting at the bottom and pro

Strona 70

Installing the Disk Enclosures 161Installation Figure 56Disk Enclosure Contents

Strona 71 - Array Design Considerations

162 Installing the Disk EnclosuresStep 3: Install Mounting RailsSelect the rail kit for the appropriate rack and follow the instructions includ

Strona 72

Installing the Disk Enclosures 163Installation Figure 57Mounting the Disk Enclosure (Rack System/E shown)A Front Mounting Ears C RailB Chassi

Strona 73 - Performance

164 Installing the Disk EnclosuresCAUTIONTo protect the door, do not lift or move the disk enclosure with the door open.3. Unlock and open the

Strona 74

Installing the Disk Enclosures 165Installation7. If using an HP rack, fasten the back of the disk enclosure to the rails using the rear hold-dow

Strona 75 - Expanding Storage Capacity

166 Installing the Disk EnclosuresStep 5: Install Disks and FillersCAUTIONTouching exposed areas on the disk can cause electrical discharge and

Strona 76

Installing the Disk Enclosures 167Installation1. Open the disk enclosure door.2. Put on the ESD strap (provided with the accessories) and insert

Strona 77 - Configuration Considerations

168 Installing the Disk Enclosures6. Open the cam latch (C Figure 60) by pulling the tab toward you.7. Align the disk insertion guide (F) with

Strona 78

Installing the Disk Enclosures 169InstallationNoteWhat if LUN 0 is on disks in the enclosure?If any of the disks in the enclosure are part of LU

Strona 79

Product Description171 PRODUCT DESCRIPTION Product Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 80

170 Installing the ControllerInstalling the ControllerThis procedure describes how to install the Disk Array FC60 controller enclosure into an

Strona 81 - Figure 25

Installing the Controller 171Installation Table 23 Controller Package ContentsFigure Label Part Description (See)A Controller chassis with pre

Strona 82 - Maximum Capacity

172 Installing the Controller Figure 62Controller Enclosure Package Contents

Strona 83 - Figure 26

Installing the Controller 173InstallationStep 3: Install Mounting Rails Select the rail kit for the appropriate rack and follow the instructions

Strona 84

174 Installing the Controller Figure 63Mounting the Controller Enclosure

Strona 85 - Figure 27

Installing the Controller 175Installation5. If installing in an HP rack, secure the back of the enclosure to the rails using the two rail clamps

Strona 86

176 Configuration SwitchesConfiguration Switches This section describes the configuration switches on the controller enclosure and the disk e

Strona 87 - Figure 28

Configuration Switches 177InstallationNoteNote that one BCC is inverted with respect to the other. Thus, the settings on one BCC appear as inve

Strona 88

178 Configuration Switches Full-Bus/Split-Bus (Switch 1) Configuration The disk enclosure’s internal bus connects the disk drives togeth

Strona 89 - Figure 29

Configuration Switches 179Installationa low range of IDs (0, 1, 2, 3, and 4) and a high range of IDs (8, 9, 10, 11, and 12). (BCCs are also prov

Strona 90

18 Product DescriptionProduct DescriptionThe HP SureStore E Disk Array FC60 (Disk Array FC60) is a disk storage system that features high data

Strona 91 - Figure 30

180 Configuration Switchescontroller module A (Fibre Channel connector J3) and Host ID BD2 SW2 selects the address for controller module B (Fib

Strona 92

Configuration Switches 181Installation Figure 65Fibre Channel Connectors and Fibre Channel Host (Loop) ID SwitchesNoteOccasionally two or more

Strona 93 - Figure 31

182 Configuration Switches. Table 26 Fibre Channel AddressesDecimal Binary Decimal Binary Decimal Binary Decimal Binary0123456789101112131415

Strona 94

Attaching Power Cords 183InstallationAttaching Power CordsEach enclosure (controller and disk enclosures) contains dual power supplies that must

Strona 95 - Figure 32

184 Attaching Power Cordsletters among all disk enclosures. “Cascading” refers to overload faults that occur on a backup PDU as a result of pow

Strona 96

Attaching Power Cords 185Installation Figure 66Wiring Scheme for 1.6-Meter RackAAAAAC INBBBBCCCCAC INDDDD30A PDRU 30A PDRUADADACACBCBCBDBD

Strona 97 - Figure 33

186 Attaching Power Cords Figure 67Wiring Scheme for 2.0-Meter RackAEAFAGBEBFBHCFCGCHDGDHAAAAAC INBBBBCCCCAC INDDDDEEEEAC INFFFFGGGGAC INHHHH

Strona 98

Attaching SCSI Cables and Configuring the Disk Enclosure Switches 187InstallationAttaching SCSI Cables and Configuring the Disk Enclosure Switch

Strona 99 - Figure 34

188 Attaching SCSI Cables and Configuring the Disk Enclosure SwitchesFull-Bus Cabling and Switch ConfigurationCabling for a full bus configura

Strona 100 - Total Disk Array Capacity

Attaching SCSI Cables and Configuring the Disk Enclosure Switches 189Installation Figure 68Full Bus BCC Configuration Switch SettingsSegment 1 s

Strona 101 - Table 7

Product Description 19Product DescriptionFigure 1HP SureStore E Disk Array FC60 (Controller with Six Disk Enclosures)SureStore E Disk System SC1

Strona 102 - Topologies for HP-UX

190 Attaching SCSI Cables and Configuring the Disk Enclosure Switches Figure 69Full-Bus CablingSCSI terminator required here

Strona 103 - Basic Topology

Attaching SCSI Cables and Configuring the Disk Enclosure Switches 191InstallationSplit-Bus Switch and Cabling ConfigurationsSplit-bus cabling re

Strona 104

192 Attaching SCSI Cables and Configuring the Disk Enclosure SwitchesFigure 70Split- Bus Configuration Switch Settings Tray ID set to unique va

Strona 105 - Planning

Attaching SCSI Cables and Configuring the Disk Enclosure Switches 193Installation Figure 71Split-Bus CablingSCSI terminatorsrequired on bothBCC

Strona 106

194 Attaching SCSI Cables and Configuring the Disk Enclosure SwitchesBus Addressing ExamplesEach disk module within the disk array is identifie

Strona 107 - Figure 37

Attaching SCSI Cables and Configuring the Disk Enclosure Switches 195Installation Figure 73Full-Bus Addressing Example This disk is on channel 4

Strona 108 - Table 8

196 Connecting the Fibre Channel CablesConnecting the Fibre Channel CablesFibre Channel cables provide the I/O path to the disk array. The Fibr

Strona 109

Connecting the Fibre Channel Cables 197InstallationFigure 74MIA, RFI Gasket, and Fibre Channel Installation3. Connect the Fibre Channel connecto

Strona 110

198 Applying Power to the Disk ArrayApplying Power to the Disk Array Once the hardware installation is complete, the disk array can be powered

Strona 111

Applying Power to the Disk Array 199InstallationFigure 75Disk Enclosure Power Switch and System LEDs 3. Check the LEDs on the front of the disk

Strona 112 - Figure 38

2Notice© Hewlett-Packard Company, 1999, 2000. All rights reserved.Hewlett-Packard Company makes no warranty of any kind with regard to this document,

Strona 113 - Table 9

20 Product DescriptionOperating System SupportThe Disk Array FC60 is currently supported on the following operating systems:•HP-UX 11.0, 11.11,

Strona 114

200 Applying Power to the Disk ArrayFigure 76Controller Enclosure Power Switches5. Check the controller enclosure LEDs (see Figure 78). The Pow

Strona 115 - High Availability Topology

Applying Power to the Disk Array 201InstallationTable 27 Normal LED Status for the Disk Enclosure Module LED Normal State Front

Strona 116

202 Applying Power to the Disk Array Figure 77Disk Enclosure LEDs A System fault LEDB System power LEDC Disk activity LEDD Disk fault LED

Strona 117 - Figure 39

Applying Power to the Disk Array 203InstallationTable 28 Normal LED Status for Controller EnclosureModule LED Normal StateController EnclosureP

Strona 118 - Table 10

204 Applying Power to the Disk ArrayFigure 78Controller Enclosure LEDs A Power On LEDB Power Fault LEDC Fan Fault LEDD Controller Fault LEDE Fa

Strona 119

Applying Power to the Disk Array 205InstallationPowering Down the Array When powering down the disk array, the controller enclosure should be p

Strona 120

206 Verifying Disk Array ConnectionVerifying Disk Array ConnectionOn Windows NT and Windows 2000The HP Storage Manager 60 software is used to v

Strona 121

Verifying Disk Array Connection 207InstallationFigure 79IOSCAN OutputClass I H/W Path Driver State H/W Type Description

Strona 122 - Figure 40

208 Verifying Disk Array ConnectionInterpreting Hardware Paths Each component on the disk array is identified by a unique hardware path. The in

Strona 123 - Table 11

Verifying Disk Array Connection 209InstallationThe port value will always be 255 when using PDA. The loop address, Fibre Channel Host ID of the

Strona 124

Product Description 21Product Description•RAID levels 0, 1, 0/1, 3, and 5 (RAID level 3 supported on Windows NT and Windows 2000 only)•EMS hardw

Strona 125 - Campus Topology

210 Verifying Disk Array ConnectionVSA is an enhancement that increases the number of LUNs that can be addressed on a fibre channel disk array

Strona 126 - Figure 41

Verifying Disk Array Connection 211InstallationThe following information is returned:SCSI describe of dev/rdsk/c9t1d0 vendor: hpproduct: idtype:

Strona 127 - Table 12

212 Verifying Disk Array ConnectionA quick way to determine the LUN number is to multiply the value of the next-to-last segment times 8, and ad

Strona 128

Installing the Disk Array FC60 Software (HP-UX Only) 213InstallationInstalling the Disk Array FC60 Software (HP-UX Only)Once the disk array hard

Strona 129

214 Installing the Disk Array FC60 Software (HP-UX Only)Verifying the Operating SystemThe Disk Array FC60 is supported on the following operati

Strona 130 - Figure 43

Installing the Disk Array FC60 Software (HP-UX Only) 215Installationswlist 3. Execute the following command to create the required device files

Strona 131

216 Configuring the Disk ArrayConfiguring the Disk Array HP-UXAfter installing the disk array software, the following steps must be performed

Strona 132 - Unsupported Windows Topology

Configuring the Disk Array 217InstallationStep 3. Reformat Disk Array MediaCAUTIONThis step will destroy all data on the disk array and remove a

Strona 133 - Characteristics

218 Configuring the Disk ArrayStep 5. Replace LUN 0 LUN 0 was created solely to allow the host to communicate with the disk array when it is fi

Strona 134 - Figure 45

Configuring the Disk Array 219Installationsettings on the host to ensure valid time stamps. This ensures that any information created by the dis

Strona 135 - Figure 46

22 Product Descriptionmodules. This provides a storage capacity range from 36 Gbytes to over 3 Tbytes of usable storage.LED Status MonitoringBo

Strona 136 - Figure 47

220 Configuring the Disk Array•For more information, see "Adding a Global Hot Spare" on page 296•To use SAM, see "Adding a Globa

Strona 137 - High Availability Topologies

Configuring the Disk Array 221Installation6. Set up storage partitions if this premium feature is enabled.7. Set the disk array controller clock

Strona 138 - Figure 48

222 Using the Disk Array FC60 as a Boot Device (HP-UX Only)Using the Disk Array FC60 as a Boot Device (HP-UX Only)The Disk Array FC60 is suppor

Strona 139 - Figure 49

Solving Common Installation Problems 223InstallationSolving Common Installation ProblemsProblem. When performing an ioscan, the host sees the di

Strona 140 - Figure 50

224 Adding Disk Enclosures to Increase CapacityAdding Disk Enclosures to Increase CapacityScalability is an important part of the design of the

Strona 141 - Figure 51

Adding Disk Enclosures to Increase Capacity 225Installation•Consider Adding More Than One Disk Enclosure - Because the process of adding disk en

Strona 142

226 Adding Disk Enclosures to Increase Capacity2. Identify the expanded disk array layout by performing the following tasks:a. Create a detaile

Strona 143 - 3INSTALLATION

Adding Disk Enclosures to Increase Capacity 227InstallationCAUTIONDo not proceed to the next step if any LUN is not in an optimal state and you

Strona 144 - Overview

228 Adding Disk Enclosures to Increase Capacity5. Configure the necessary disk enclosures for full-bus operation. See "Configuration Switc

Strona 145 - Host System Requirements

Adding Disk Enclosures to Increase Capacity 229Installation8. Set the disk Enclosure (Tray) ID switches. See "Disk Enclosure (Tray) ID Swit

Strona 146 - Windows NT and Windows 2000

Disk Enclosure Components 23Product DescriptionDisk Enclosure ComponentsThe SureStore E Disk System SC10, or disk enclosure, is a high availabil

Strona 147 - Site Requirements

230 Adding Disk Enclosures to Increase CapacityStep 5. Completing the ExpansionCAUTIONThe disk array components must be powered up in the speci

Strona 148

Adding Disk Enclosures to Increase Capacity 231Installationtaken not to cross the cables, as this may cause problems with applications that depe

Strona 149

232 Adding Disk Enclosures to Increase CapacityCapacity Expansion ExampleAn example of expanding an Disk Array FC60 is shown in Figure 83. In t

Strona 150

Adding Disk Enclosures to Increase Capacity 233InstallationFigure 83Capacity Expansion ExampleDisks are moved to the slotthat corresponds to the

Strona 151

234 Adding Disk Enclosures to Increase Capacity

Strona 152 - Recommended UPS Models

Adding Disk Enclosures to Increase Capacity 235InstallationFigure 84Capacity Expansion MapFull-bus IDsFull-bus IDsFull-bus IDsFull-bus IDs 00008

Strona 153 - Figure 52

236 Adding Disk Enclosures to Increase CapacityFull-bus IDsFull-bus IDsFull-bus IDsFull-bus IDs 0000888811119999222210101010 333311111111 44441

Strona 154 - Figure 53

Managing the Disk Array on HP-UX2374 MANAGING THE DISK ARRAY ON HP-UX Tools for Managing the Disk Array FC60 . . . . . . . . . . . . . . . . . . . . .

Strona 155 - Installation

238 Tools for Managing the Disk Array FC60Tools for Managing the Disk Array FC60NoteOn Windows NT and Windows 2000, the disk array is managed u

Strona 156

Tools for Managing the Disk Array FC60 239Managing the Disk Array on HP-UXTable 30 Management Tools and Tasks Task ToolSAM Array Manager 60 ST

Strona 157

24 Disk Enclosure Components Figure 2 Disk Enclosure Components, Exploded ViewFan ModulesBCC ModulesPower Supply Modules(Front Door Not Shown)

Strona 158 - Figure 54

240 Installing the Array Manager 60 SoftwareInstalling the Array Manager 60 SoftwareThe Array Manager 60 software must be installed on the host

Strona 159 - Figure 55

Installing the Array Manager 60 Software 241Managing the Disk Array on HP-UXAM60Srvr DaemonThe AM60Srvr daemon is the server portion of the Arra

Strona 160 - Step 2: Unpack the Product

242 Managing Disk Array CapacityManaging Disk Array CapacityDuring installation, a LUN structure is created on the disk array. This structure m

Strona 161 - Figure 56

Managing Disk Array Capacity 243Managing the Disk Array on HP-UXSelecting Disks for a LUNWhen binding a LUN , you must select the disks that wi

Strona 162

244 Managing Disk Array CapacitySelecting disks in the incorrect order of 1:2, 2:2, 1:3, and 2:3 results in mirrored pairs of 1:2/1:3 and 2:2/2

Strona 163 - Figure 57

Managing Disk Array Capacity 245Managing the Disk Array on HP-UXinternal management of enclosure components.) If the disk enclosure is configur

Strona 164 - Door Lock

246 Managing Disk Array CapacityFigure 86Disk Module Addressing Parameters01 2 3456 789Slot Numbers012348 9 10 11 12SCSI IDsDisk enclosure ID s

Strona 165

Managing Disk Array Capacity 247Managing the Disk Array on HP-UXAssigning LUN Ownership When a LUN is bound, you must identify which disk

Strona 166

248 Managing Disk Array Capacitythe RAID level used by a LUN, you must unbind the LUN and rebind it using the new RAID level. With the exceptio

Strona 167

Managing Disk Array Capacity 249Managing the Disk Array on HP-UX•If you choose to limit the number of global hot spares, make sure you are able

Strona 168

Disk Enclosure Components 25Product DescriptionOperation FeaturesThe disk enclosure is designed to be installed in a standard 19-inch rack and o

Strona 169

250 Managing Disk Array CapacityEvaluating Performance ImpactSeveral disk array configuration settings have a direct impact on I/O performance

Strona 170 - Installing the Controller

Managing Disk Array Capacity 251Managing the Disk Array on HP-UXSetting: Cache flush threshold (default 80%)Function: Sets the level at which th

Strona 171 - Table 23

252 Managing Disk Array CapacitySetting: Cache flush limit (default 100%)Function: Determines how much data will remain in write cache when flu

Strona 172 - Figure 62

Managing Disk Array Capacity 253Managing the Disk Array on HP-UXFigure 87Cache Flush Threshold ExampleWrite DataWrite DataWrite Data80%80%80%Cac

Strona 173

254 Adding Capacity to the Disk ArrayAdding Capacity to the Disk ArrayAs your system storage requirements grow, you may need to increase the ca

Strona 174 - Figure 63

Adding Capacity to the Disk Array 255Managing the Disk Array on HP-UX2. Bind a LUN with the new disks using the management tool of your choice,:

Strona 175

256 Adding Capacity to the Disk ArrayAdding Additional Disk EnclosuresAdding additional disk enclosures is another way to increase the capacity

Strona 176 - Configuration Switches

Adding Capacity to the Disk Array 257Managing the Disk Array on HP-UX6. Bind a LUN with the new disks using the management tool of your choice:–

Strona 177

258 Upgrading Controller Cache to 512 Mbytes Upgrading Controller Cache to 512 MbytesController cache can be upgraded from the standard 256 Mb

Strona 178

Upgrading Controller Cache to 512 Mbytes 259Managing the Disk Array on HP-UXTable 32 Controller Cache Upgrade Kit SelectionInitial controller

Strona 179

26 Disk Enclosure Components Figure 3Disk Enclosure Front and Back ViewPower Switch The power switch (B in Figure 3) interrupts power from t

Strona 180

260 Managing the Disk Array Using SAMManaging the Disk Array Using SAMMost of the tasks involved in everyday management of the disk array can b

Strona 181

Managing the Disk Array Using SAM 261Managing the Disk Array on HP-UXChecking Disk Array StatusAll aspects of disk array operation are continual

Strona 182 - Table 26

262 Managing the Disk Array Using SAM3. Select a controller for the appropriate disk array from the Disk Devices list.4. Select the Actions men

Strona 183 - Attaching Power Cords

Managing the Disk Array Using SAM 263Managing the Disk Array on HP-UXGeneral disk array status displayed hereClick hereClick hereClick hereClick

Strona 184

264 Managing the Disk Array Using SAMInterpreting Status IndicatorsA common set of colored status indicators are used to convey the current ope

Strona 185 - Figure 66

Managing the Disk Array Using SAM 265Managing the Disk Array on HP-UX4. Select the Actions menu, the Disk Array Maintenance menu option, then Mo

Strona 186 - Figure 67

266 Managing the Disk Array Using SAM5. Click the Disk Module Status button. The Disk Status window is displayed. Select the option to flash LE

Strona 187 - Attaching SCSI Cables and

Managing the Disk Array Using SAM 267Managing the Disk Array on HP-UX6. Select the disk you want to identify. A check mark will appear on the se

Strona 188

268 Managing the Disk Array Using SAMTo bind a LUN:1. On the main SAM screen, double-click the Disks and File Systems icon.2. On the Disks and

Strona 189

Managing the Disk Array Using SAM 269Managing the Disk Array on HP-UXOrder of selected disks displayed hereSelectunassigneddisks for anew LUN

Strona 190 - Figure 69

Disk Enclosure Components 27Product DescriptionDisk Enclosure SC10 Modules The disk enclosure hot-swappable modules include the following:•Disks

Strona 191

270 Managing the Disk Array Using SAM5. Click the LUN # button and select the desired number for the LUN. You can also enter the LUN number dir

Strona 192

Managing the Disk Array Using SAM 271Managing the Disk Array on HP-UXUnbinding a LUNUnbinding a LUN makes its capacity available for the creatio

Strona 193 - SCSI terminators

272 Managing the Disk Array Using SAMNoteCan I replace any LUN on the disk array?Yes. In addition, the replace command is the only way you can

Strona 194 - Bus Addressing Examples

Managing the Disk Array Using SAM 273Managing the Disk Array on HP-UXAdding a Global Hot SpareGlobal hot spares provide an additional level of p

Strona 195 - This disk is on

274 Managing the Disk Array Using SAMUnassigneddisksselected as hot spares

Strona 196

Managing the Disk Array Using SAM 275Managing the Disk Array on HP-UX5. Select the disk to be used as a global hot spare.Only unassigned disks,

Strona 197

276 Managing the Disk Array Using Array Manager 60Managing the Disk Array Using Array Manager 60 The Array Manager 60 command line utilities al

Strona 198

Managing the Disk Array Using Array Manager 60 277Managing the Disk Array on HP-UXDisk Array ConfigurationAssigning an Alias to the Disk Arrayam

Strona 199

278 Managing the Disk Array Using Array Manager 60Table 34 Array Manager 60 Command Summary Command Tasksamcfg Binding a LUNUnbinding a LUNCha

Strona 200

Managing the Disk Array Using Array Manager 60 279Managing the Disk Array on HP-UXCommand Syntax ConventionsThe following symbols are used in th

Strona 201 - Table 27

28 Disk Enclosure Components Figure 4Disk ModuleDisks fit snugly in their slots. The cam latch (B in Figure 4) is used to seat and unseat th

Strona 202 - Figure 77

280 Managing the Disk Array Using Array Manager 60Selecting a Disk Array and Its ComponentsWhen using Array Manager 60, you must select the dis

Strona 203

Managing the Disk Array Using Array Manager 60 281Managing the Disk Array on HP-UXPreparing to Manage the Disk ArrayBefore you begin using Array

Strona 204 - Figure 78

282 Managing the Disk Array Using Array Manager 60Checking Disk Array StatusAn important part of managing the disk array involves monitoring it

Strona 205 - Powering Down the Array

Managing the Disk Array Using Array Manager 60 283Managing the Disk Array on HP-UXCommand ExampleThe following example all status information fo

Strona 206 - On HP-UX

284 Managing the Disk Array Using Array Manager 60Figure 88Disk Array Sample Status Output (amdsp)Vendor ID = HPProduct ID =

Strona 207

Managing the Disk Array Using Array Manager 60 285Managing the Disk Array on HP-UXVendor ID = HPProduct ID = A5277AArray ID

Strona 208 - 8/12.8.0.255.1.2.0

286 Managing the Disk Array Using Array Manager 60Information for Controller A - 000A00A0B80673A6: Controller Status = GOOD Controller Mo

Strona 209 - 8/12.8.0.6.0.1.3

Managing the Disk Array Using Array Manager 60 287Managing the Disk Array on HP-UXVendor ID = HPProduct ID = A5277AArray ID

Strona 210

288 Managing the Disk Array Using Array Manager 60Listing Disk Array IDsYou may find it useful to list the disk arrays recognized by the host.

Strona 211 - 8/12.8.0.0.0.3.5

Managing the Disk Array Using Array Manager 60 289Managing the Disk Array on HP-UXManaging LUNsUsing Array Manager 60 you can perform the follow

Strona 212 - (3 x 8) + (5) = 29

Disk Enclosure Components 29Product DescriptionBCCs Two Backplane Controller Cards, BCCs, control the disks on one or two buses according to the

Strona 213 - System Requirements

290 Managing the Disk Array Using Array Manager 60•RAIDlevel - RAID level used for the LUN. Valid RAID levels are 0, 1, and 5. RAID 0 support r

Strona 214

Managing the Disk Array Using Array Manager 60 291Managing the Disk Array on HP-UXCommand ExamplesThe following example binds a 5-disk, RAID 5 L

Strona 215

292 Managing the Disk Array Using Array Manager 60Identifying DisksBinding a LUN requires the use of unassigned disks. If you are not sure whic

Strona 216 - Configuring the Disk Array

Managing the Disk Array Using Array Manager 60 293Managing the Disk Array on HP-UXUnbinding a LUNUnbinding a LUN makes its capacity available fo

Strona 217

294 Managing the Disk Array Using Array Manager 60NoteDoes the primary path selected using LVM impact LUN ownership?Yes. The primary path estab

Strona 218 - Step 5. Replace LUN 0

Managing the Disk Array Using Array Manager 60 295Managing the Disk Array on HP-UXTo replace a LUN, type:amcfg -R <cntrlrID>:<LUN> -

Strona 219 - Step 8. Bind LUNs

296 Managing the Disk Array Using Array Manager 60Adding a Global Hot SpareA global hot spare is added using an unassigned disk. If there are n

Strona 220

Managing the Disk Array Using Array Manager 60 297Managing the Disk Array on HP-UXManaging Disk Array ConfigurationAssigning an Alias to the Dis

Strona 221

298 Managing the Disk Array Using Array Manager 60Managing the Universal Transport Mechanism (UTM)On firmware HP08 and later, the Universal Tra

Strona 222

Managing the Disk Array Using Array Manager 60 299Managing the Disk Array on HP-UXNoteAfter executing the above command, the disk array controll

Strona 223

3Format ConventionsDenotesWARNINGA hazard that can cause personal injuryCaution A hazard that can cause hardware or software damageNote Significant c

Strona 224

30 Disk Enclosure ComponentsEach BCC provides two LVD SCSI ports (B in Figure 5) for connection to the controller enclosure.The EEPROM on each

Strona 225

300 Managing the Disk Array Using Array Manager 60see Table 31 on page 250 for details on what performance impact altering these settings may h

Strona 226

Managing the Disk Array Using Array Manager 60 301Managing the Disk Array on HP-UXSetting the Cache Flush LimitSets the amount of unwritten data

Strona 227

302 Managing the Disk Array Using Array Manager 60Disabling Disk Module Write Cache Enable (WCE)NoteTo ensure optimum protection against data l

Strona 228

Managing the Disk Array Using Array Manager 60 303Managing the Disk Array on HP-UXEnabling Disk Write Cache Enable (WCE)CAUTIONWCE should only b

Strona 229

304 Managing the Disk Array Using Array Manager 60Performing Disk Array MaintenanceAt some point during operation of the disk array, you may ne

Strona 230

Managing the Disk Array Using Array Manager 60 305Managing the Disk Array on HP-UXManaging the Rebuild ProcessIf a disk fails, the disk array au

Strona 231

306 Managing the Disk Array Using Array Manager 60•amount identifies the number of blocks to rebuild at a time. This value can be from 1 to 64K

Strona 232 - Capacity Expansion Example

Managing the Disk Array Using Array Manager 60 307Managing the Disk Array on HP-UXA parity scan compares the data and its associated parity to e

Strona 233

308 Managing the Disk Array Using Array Manager 60previous firmware releases are logged in the major event log. Earlier versions of firmware (p

Strona 234

Managing the Disk Array Using Array Manager 60 309Managing the Disk Array on HP-UXViewing Disk Array LogsTo display the disk array controller lo

Strona 235 - Figure 84

Disk Enclosure Components 31Product DescriptionFansRedundant, hot-swappable fans provide cooling for all enclosure components. Each fan has two

Strona 236

310 Managing the Disk Array Using Array Manager 60actual ArrayID must be used here. An alias cannot be used because alias names are not recorde

Strona 237

Managing the Disk Array Using Array Manager 60 311Managing the Disk Array on HP-UX FRU State = FailedDecoded SCSI Sense:Non-media

Strona 238 - Array Manager 60

312 Managing the Disk Array Using Array Manager 60To purge the oldest log file in the host directory, type:amutil -p NoteAlways use the amutil

Strona 239 - Table 30

Managing the Disk Array Using Array Manager 60 313Managing the Disk Array on HP-UXNoteThe patches are not currently included on the HP-UX Suppor

Strona 240

314 Managing the Disk Array Using STMManaging the Disk Array Using STMSTM is an online diagnostic tool, but it can be used to perform some of t

Strona 241 - Running Array Manager 60

Managing the Disk Array Using STM 315Managing the Disk Array on HP-UXUnbinding a LUNThe STM Expert Tool can be used to unbind a LUN. See "U

Strona 242 - Managing Disk Array Capacity

316 Managing the Disk Array Using STMLocating Disk ModulesThe STM Expert Tool can be used to locate disk modules. to aid in identification. The

Strona 243 - Selecting Disks for a LUN

Status Conditions and Sense Code Information 317Managing the Disk Array on HP-UXStatus Conditions and Sense Code InformationThe following tables

Strona 244

318 Status Conditions and Sense Code InformationAM60: DEGRADED--REPLACED DISK BEING REBUILTSTM: DEGRADED - 2A rebuild is in progress on the LUN

Strona 245 - Increasing LUN Capacity

Status Conditions and Sense Code Information 319Managing the Disk Array on HP-UXDisk Status ConditionsThe disk status condition terminology used

Strona 246

32 Disk Enclosure ComponentsPower SuppliesRedundant, hot-swappable 450-watt power supplies convert wide-ranging AC voltage from an external mai

Strona 247 - Selecting a RAID Level

320 Status Conditions and Sense Code InformationAM60: READ FAILEDSTM: FLT - 19The disk array could not read from the disk.Replace the failed di

Strona 248 - Global Hot Spares

Status Conditions and Sense Code Information 321Managing the Disk Array on HP-UXComponent Status ConditionsComponent status conditions are organ

Strona 249

322 Status Conditions and Sense Code InformationFRU CodesThe FRU codes indicate which disk array component is responsible for the log entry. Lo

Strona 250 - Evaluating Performance Impact

Status Conditions and Sense Code Information 323Managing the Disk Array on HP-UX0x08 Disk Enclosure Group - comprises attached disk enclosures.

Strona 251

324 Status Conditions and Sense Code InformationController Enclosure Group FRU Code QualifierWhen the Controller Enclosure group is identified

Strona 252 - Cache page size

Status Conditions and Sense Code Information 325Managing the Disk Array on HP-UXComponent ID Value Component0 Unspecified1Device2 Power Supply3

Strona 253 - Initial cache settings

326 Status Conditions and Sense Code InformationDisk Enclosure Group FRU Code QualifierWhen the Disk Enclosure group is identified (FRU Code =

Strona 254 - Adding More Disk Modules

Status Conditions and Sense Code Information 327Managing the Disk Array on HP-UXSCSI Sense CodesTable 44 lists the SCSI sense codes that may be

Strona 255 - Managing the Disk Array

328 Status Conditions and Sense Code Information0C 00If the accompanying sense key = 4, error is interrupted as follows:Unrecovered Write Error

Strona 256

Status Conditions and Sense Code Information 329Managing the Disk Array on HP-UX11 00 Unrecovered Read ErrorAn unrecovered read operation to a d

Strona 257

Disk Enclosure Components 33Product DescriptionPower supplies share the load reciprocally; that is, each supply automatically increases its outp

Strona 258

330 Status Conditions and Sense Code Information21 00 Logical Block Address Out of RangeThe controller received a command that requested an ope

Strona 259 - Table 32

Status Conditions and Sense Code Information 331Managing the Disk Array on HP-UX29 04 Device Internal ResetThe controller has reset itself due t

Strona 260

332 Status Conditions and Sense Code Information2F 00 Commands Cleared by Another InitiatorThe controller received a Clear Queue message from a

Strona 261 - Checking Disk Array Status

Status Conditions and Sense Code Information 333Managing the Disk Array on HP-UX3F 8N Drive No Longer Usable.The controller has set a drive to a

Strona 262

334 Status Conditions and Sense Code Information3F BD The controller has detected a drive with Mode Select parame-ters that are not recommended

Strona 263

Status Conditions and Sense Code Information 335Managing the Disk Array on HP-UX3F D0 Write Back Cache Battery Has Been DischargedThe controller

Strona 264

336 Status Conditions and Sense Code Information40 NN Diagnostic Failure on Component NN (0x80 - 0xFF)The controller has detected the failure o

Strona 265 - Locating Disk Modules

Status Conditions and Sense Code Information 337Managing the Disk Array on HP-UX44 00 Internal Target FailureThe controller has detected a hardw

Strona 266

338 Status Conditions and Sense Code Information49 80 Drive Reported Reservation ConflictA drive returned a status of reservation conflict.4B 0

Strona 267 - Binding a LUN

Status Conditions and Sense Code Information 339Managing the Disk Array on HP-UX85 01 Drive IO Request AbortedIO Issued to Failed or Missing dri

Strona 268

34 Array Controller Enclosure ComponentsArray Controller Enclosure Components The array controller enclosure, like the disk enclosure, consists

Strona 269

340 Status Conditions and Sense Code Information8B 02 Quiescence Is In Progress or Has Been Achieved8B 03 Quiescence Could Not Be Achieved With

Strona 270

Status Conditions and Sense Code Information 341Managing the Disk Array on HP-UX91 36 Command Lock ViolationThe controller received a Write Buff

Strona 271 - Replacing a LUN

342 Status Conditions and Sense Code Information95 02 Controller Removal/Replacement Detected or Alternate Con-troller Released from ResetThe c

Strona 272

Status Conditions and Sense Code Information 343Managing the Disk Array on HP-UXA6 00 Recovered processor memory failureThe controller has detec

Strona 273 - Adding a Global Hot Spare

344 Status Conditions and Sense Code InformationE0 20/21 Fibre Channel Destination Channel ErrorASCQ = 20: Indicates redundant path is not avai

Strona 274 - Unassigned

HP-UX Diagnostic Tools3455 HP-UX DIAGNOSTIC TOOLSOverview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 275 - Removing a Global Hot Spare

346 OverviewOverviewSTM (Support Tools Manager) is the primary diagnostic tool available for the Disk Array FC60. For diagnosing problems, STM

Strona 276

Support Tools Manager 347HP-UX Diagnostic ToolsSupport Tools ManagerThe STM host-based utility provides capability for managing the Disk Array F

Strona 277 - Table 33

348 Support Tools Managerxstm — the X Windows Interface xstm is the X-Windows screen-based STM interface. Because it is the easiest to use, xst

Strona 278 - Table 34

Support Tools Manager 349HP-UX Diagnostic Toolsmstm — the Menu-based Interfacemstm is the menu-based STM interface. It serves as an alternate in

Strona 279 - Quick Help

Array Controller Enclosure Components 35Product Description Figure 8Controller Enclosure Exploded View During operation, controller enclosure s

Strona 280

350 Support Tools ManagerFigure 90mstm Interface Main Window

Strona 281

Support Tools Manager 351HP-UX Diagnostic ToolsSTM ToolsThe STM tools available for use with the HP SureStore E Disk Array FC60 are listed in Ta

Strona 282

352 Support Tools ManagerUsing the STM Information ToolThe STM Information Tool gathers status and configuration information about the selected

Strona 283

Support Tools Manager 353HP-UX Diagnostic ToolsRunning Information Tool in Menu Mode 1. At the system prompt:– Type mstm– Select Ok2. To select

Strona 284 - Figure 88

354 Support Tools ManagerInterpreting the Information Tool Information LogThe Information Log contains status and configuration information for

Strona 285

Support Tools Manager 355HP-UX Diagnostic ToolsUsing the STM Expert ToolThe Expert Tool provides the capability to manage the HP SureStore E Dis

Strona 286

356 Support Tools ManagerRunning Expert Tool in Menu Mode1. At the system prompt:– Type mstm– Select Ok2. To select the disk array: – Scroll do

Strona 287

Support Tools Manager 357HP-UX Diagnostic ToolsTable 46 Expert Tool Menus and DescriptionsMenu Option Property DescriptionLogs View Event Log N

Strona 289 - Managing LUNs

Troubleshooting3596 TROUBLESHOOTINGIntroduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 290

36 Array Controller Enclosure Components Figure 9Controller Enclosure Front View

Strona 291

360 IntroductionIntroductionThe modular design of the Disk Array FC60 simplifies the isolation and replacement of failed hardware components. M

Strona 292 - Calculating LUN Capacity

Introduction 361TroubleshootingAbout Field Replaceable Units (FRUs)The Disk Array FC60 consists of a Controller Enclosure and one or more SureSt

Strona 293

362 IntroductionHP-UX Troubleshooting Tools There are several tools available for troubleshooting the disk array on an HP-UX host. This include

Strona 294

Introduction 363TroubleshootingEMS Monitor Event Severity Levels Each event detected and reported by the EMS monitor is assigned a severity l

Strona 295 - Managing Global Hot Spares

364 Introduction•Probable Cause/Recommended Action – The cause of the event and suggested steps toward a solution. This information should be t

Strona 296

Disk Array Installation/Troubleshooting Checklist 365TroubleshootingDisk Array Installation/Troubleshooting ChecklistThe following checklist is

Strona 297

366 Power-Up TroubleshootingPower-Up TroubleshootingWhen the disk array is powered up, each component perform an internal self-test, to ensure

Strona 298

Controller Enclosure Troubleshooting 367TroubleshootingNoteIf no LEDs are ON and the fans are not running, it indicates that no AC power is bein

Strona 299 - Managing Cache Parameters

368 Controller Enclosure TroubleshootingController Enclosure LEDsFigure 92 shows the locations of the status LEDs for the controller enclosure.

Strona 300 - Setting Cache Page Size

Controller Enclosure Troubleshooting 369TroubleshootingTable 48 Normal LED Status for Controller EnclosureModule LED Normal StateController Enc

Strona 301 - Setting the Cache Flush Limit

Array Controller Enclosure Components 37Product Description Figure 10Controller Enclosure Rear ViewFront Cover The controller enclosure has a r

Strona 302

370 Controller Enclosure TroubleshootingMaster Troubleshooting TableTable 49 contains troubleshooting information for the controller enclosure

Strona 303

Controller Enclosure Troubleshooting 371TroubleshootingController enclosure and Fan Fault LED (front cover) are onController enclosure fan failu

Strona 304

372 Controller Enclosure TroubleshootingSoftware errors occur when attempting to access controller or disksA Software function or configuration

Strona 305 - Checking Rebuild Progress

Controller Enclosure Troubleshooting 373TroubleshootingController Fan ModuleFan Fault LED is on One or both of the fans in the controller fan mo

Strona 306 - Performing a Parity Scan

374 Controller Enclosure Troubleshooting“Battery Low” error issued by softwarePower turned OFF for extended period and drained battery power.Tu

Strona 307 - Managing Disk Array Logs

Controller Enclosure Troubleshooting 375TroubleshootingPower Supply LED (front cover) is onA Power supply module is missing or not plugged in pr

Strona 308

376 SureStore E Disk System SC10 TroubleshootingSureStore E Disk System SC10 TroubleshootingThis section contains information on identifying an

Strona 309

SureStore E Disk System SC10 Troubleshooting 377TroubleshootingFigure 93Disk Enclosure LEDs Table 50 Disk Enclosure LED FunctionsLED State Ind

Strona 310 - Sample Log Entries

378 SureStore E Disk System SC10 TroubleshootingBCC Fault AmberSelf-test1 / FaultOFF Normal operationFlashing Peer BCC DIP switch settings do n

Strona 311 - Purging Controller Logs

SureStore E Disk System SC10 Troubleshooting 379TroubleshootingNoteIt is normal for the amber Fault LED on a component to go on briefly when the

Strona 312 - Installing Updated Patches

38 Array Controller Enclosure ComponentsController ModulesThe controller enclosure contains one or two controller modules. See Figure 11. These

Strona 313 - Upgrading Disk Firmware

380 SureStore E Disk System SC10 TroubleshootingIsolating Causes Table 52 lists the probable causes and solutions for problems you may detect o

Strona 314

SureStore E Disk System SC10 Troubleshooting 381TroubleshootingPower Supply LED is amberCritical Amber Critical – An incompatible or defective c

Strona 315

382 SureStore E Disk System SC10 Troubleshooting Peer BCC status, temperature and voltage are Not AvailableMajor Warningnone Both BCCs: Non-cri

Strona 316

Removal and Replacement3837 REMOVAL AND REPLACEMENTOverview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 317 - LUN Status Conditions

384 OverviewOverviewThis chapter describes removal and replacement procedures for the disk array hot- swappable modules that are customer repla

Strona 318 - Table 40

Overview 385Removal and ReplacementNoteIs the HP SureStore E Disk Array FC60 customer repairable?Although the modular design of the Disk Array F

Strona 319 - Disk Status Conditions

386 Disk Enclosure Modules Disk Enclosure Modules This section describes the procedures for replacing the hot swappable modules in the disk enc

Strona 320 - Table 41

Disk Enclosure Modules 387Removal and ReplacementNoteWhen a disk module is replaced, the new disk inherits the group properties of the original

Strona 321 - Component Status Conditions

388 Disk Enclosure Modules Figure 94Disk Module Removal Installing a Disk Module or Filler ModuleCAUTIONTouching the disk circuit board can c

Strona 322 - FRU Codes

Disk Enclosure Modules 389Removal and ReplacementNoteIf the disk module you are installing has been removed from another Disk Array FC60, you sh

Strona 323 - Table 43

Array Controller Enclosure Components 39Product DescriptionEach controller module has ten LEDs. See Figure 12. One LED identifies the controller

Strona 324 - 76543 21 0

390 Disk Enclosure Modules5. Close the cam latch to seat the module firmly into the backplane. An audible click indicates the latch is closed p

Strona 325

Disk Enclosure Modules 391Removal and Replacement Figure 96Disk Module Replacement A handleBcam latchC capacity labelDLEDs

Strona 326

392 Disk Enclosure ModulesDisk Enclosure Fan Module ! Hot Swappable Component!A failed fan module should be replaced as soon as possible. There

Strona 327 - SCSI Sense Codes

Disk Enclosure Modules 393Removal and Replacement Figure 97Disk Enclosure Fan Module Removal and Replacement Installing the Fan Module1. Slid

Strona 328 - Table 44

394 Disk Enclosure ModulesDisk Enclosure Power Supply Module ! Hot Swappable Component!A failed power supply module should be replaced as soon

Strona 329

Disk Enclosure Modules 395Removal and Replacement Figure 98Disk Enclosure Power Supply Module Removal and Replacement Installing the Power Su

Strona 330

396 Controller Enclosure ModulesController Enclosure Modules This section provides removal and replacement procedures for the controller enclos

Strona 331

Controller Enclosure Modules 397Removal and ReplacementFront Cover Removal/Replacement ! Hot Swappable Component!To gain access to the front of

Strona 332

398 Controller Enclosure ModulesInstalling the Front Cover1. Slide the top edge of the cover up under the lip of the chassis.2. Push the cover

Strona 333

Controller Enclosure Modules 399Removal and Replacement Figure 100Controller Fan Module Removal and ReplacementInstalling the Controller Fan Mo

Strona 334

4Manual Revision HistoryDecember 2000Change PageAdded Figure 87 to clarify operation of the write cache flush thresholds. 253Added note regarding the

Strona 335

40 Array Controller Enclosure ComponentsController Memory Modules Each controller module contains SIMM and DIMM memory modules. Two 16-Mbyte SI

Strona 336

400 Controller Enclosure ModulesBattery Backup Unit (BBU) Removal/Replacement ! Hot Swappable Component!NoteIf the Fast Write Cache LED is on w

Strona 337

Controller Enclosure Modules 401Removal and Replacement Figure 101 BBU Removal and Replacement

Strona 338

402 Controller Enclosure ModulesInstalling the BBU1. Unpack the new BBU. Save the shipping material for transporting the used BBU to the dispos

Strona 339

Controller Enclosure Modules 403Removal and Replacement6. Dispose of the old BBU.NoteDispose of the used BBU according to local and federal regu

Strona 340

404 Controller Enclosure ModulesFigure 103 Power Supply Fan Module Removal and ReplacementInstalling the Power Supply Fan Module1. Slide the po

Strona 341

Controller Enclosure Modules 405Removal and ReplacementPower Supply Module Removal/Replacement! Hot Swappable Component!A power supply should be

Strona 342

406 Controller Enclosure Modules Figure 105Power Supply Module Removal and ReplacementInstalling the Power Supply Module1. Slide the supply in

Strona 343

Controller Enclosure Modules 407Removal and ReplacementSCSI CablesReplacing SCSI cables requires that the disk enclosure be shut down. Shutting

Strona 344

408 Controller Enclosure ModulesOnce the disk enclosure is powered up, check the status of the disk modules using one of the software managemen

Strona 345 - 5 HP-UX DIAGNOSTIC TOOLS

Reference / Legal / Regulatory4098 REFERENCE / LEGAL / REGULATORYModels and Options. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 346

Array Controller Enclosure Components 41Product Description Figure 13Controller Fan Module

Strona 347 - Support Tools Manager

410 System RequirementsSystem RequirementsHost SystemsHP-UXWindows NT 4.0 and Windows 2000Any host running Windows NT 4.0 or Windows 2000.Suppo

Strona 348

System Requirements 411Reference / Legal / Regulatory•Windows 2000Fibre Channel Host AdaptersHP-UX•K-class: A3404A (assy number J2389-60001), 10

Strona 349 - HP-UX Diagnostic Tools

412 Models and OptionsModels and OptionsThe HP SureStore E Disk Array FC60 consists of two products: the A5277A/AZ controller enclosure and the

Strona 350 - Figure 90

Models and Options 413Reference / Legal / Regulatory Table 54 A5277A/AZ Product Options Option Description Controller

Strona 351 - STM Tools

414 Models and OptionsA5294A/AZ Disk Enclosure SC10 Models and OptionsOrder the following product and options as required. Enter the following

Strona 352

Models and Options 415Reference / Legal / Regulatory Table 55 A5294A Custom Cabling Option Option Description 701 Dele

Strona 353

416 Models and OptionsDisk Array FC60 Upgrade and Add-On ProductsOrder the following parts to expand or reconfigure your original purchase: Ta

Strona 354

PDU/PDRU Products 417Reference / Legal / RegulatoryPDU/PDRU ProductsHewlett-Packard offers the following PDUs and PDRUs, with US and internation

Strona 355 - Using the STM Expert Tool

418 Replaceable PartsReplaceable PartsA5277A/AZ Controller Enclosure Replaceable Parts Table 60 Controller Enclosure Replaceable Parts

Strona 356

Replaceable Parts 419Reference / Legal / RegulatoryA5294A/AZ Disk Enclosure Replaceable Parts A5277-60004 Power Supply Modules n/aA5277-6000

Strona 357 - Table 46

42 Array Controller Enclosure ComponentsPower Supply Modules Two separate power supplies provide electrical power to the internal components by

Strona 358

420 A5277A/AZ Controller Enclosure SpecificationsA5277A/AZ Controller Enclosure SpecificationsDimensions: Weight: Height Width Depth 6.75

Strona 359 - 6 TROUBLESHOOTING

A5277A/AZ Controller Enclosure Specifications 421Reference / Legal / RegulatoryAC Power:AC Voltage and Frequency:•120 VAC (100 - 127 VAC), 50

Strona 360 - Introduction

422 A5277A/AZ Controller Enclosure SpecificationsEnvironmental SpecificationsNoteThe HP SureStore E Disk Array FC60 has been tested for proper

Strona 361 - Table 47

A5277A/AZ Controller Enclosure Specifications 423Reference / Legal / RegulatoryNon-operating Environmental (shipping and storage):•Temperature:

Strona 362 - HP-UX Troubleshooting Tools

424 A5294A/AZ Disk Enclosure SpecificationsA5294A/AZ Disk Enclosure SpecificationsDimensions: Weight: Height Width Depth5.91 in. (15.0 cm)

Strona 363 - Sample EMS Event Message

A5294A/AZ Disk Enclosure Specifications 425Reference / Legal / RegulatoryAC Power:AC Voltage and Frequency:•100 - 127 VAC, 50 to 60 Hz single

Strona 364 - Figure 91

426 A5294A/AZ Disk Enclosure SpecificationsEnvironmental SpecificationsNoteThe HP SureStore E Disk Array FC60 has been tested for proper operat

Strona 365 - Troubleshooting

A5294A/AZ Disk Enclosure Specifications 427Reference / Legal / RegulatoryNoteFor continuous, trouble-free operation, the disk enclosure should N

Strona 366 - Power-Up Troubleshooting

428 Warranty and License InformationWarranty and License InformationHewlett-Packard Hardware Limited WarrantyHP warrants to you, the end-user C

Strona 367

Warranty and License Information 429Reference / Legal / RegulatorySoftware Product Limited WarrantyThe HP Software Product Limited Warranty will

Strona 368 - Controller Enclosure LEDs

Array Controller Enclosure Components 43Product DescriptionEach power supply is equipped with a power switch to disconnect power to the supply.

Strona 369

430 Warranty and License InformationThis warranty extends only to the original owner in the original country of purchase and is not transferabl

Strona 370 - Master Troubleshooting Table

Warranty and License Information 431Reference / Legal / RegulatoryRANTY STATEMENT ARE CUSTOMER'S SOLE AND EXCLUSIVE REMEDIES. EXCEPT AS IND

Strona 371

432 Warranty and License InformationSoftware or disable any licensing or control features of the Software. If the Software is licensed for &quo

Strona 372

Warranty and License Information 433Reference / Legal / RegulatoryRestricted Rights Legend1.) Use, duplication or disclosure by the U.S. Governm

Strona 373

434 Regulatory Compliance Regulatory ComplianceSafety Certifications:•UL listed•CUL certified•TUV certified with GS mark•Gost Certified•CE-Mark

Strona 374

FCC Statements (USA Only) 435Reference / Legal / RegulatoryFCC Statements (USA Only)The Federal Communications Commission (in 47 CFR 15.105) has

Strona 375

436 FCC Statements (USA Only)VCCI Statement (Japan)This equipment is in the Class A category information technology equipment based on the rule

Strona 376 - Losing LUN 0

FCC Statements (USA Only) 437Reference / Legal / RegulatorySpécification ATI Classe A (France Seulement)DECLARATION D'INSTALLATION ET DE MI

Strona 377 - Disk Enclosure LED Functions

438 FCC Statements (USA Only)Geräuschemission (For Germany Only)•LpA: 45.0 dB (suchend)•Am fiktiven Arbeitsplatz nach DIN 45635 T. 19.•Die Date

Strona 378

FCC Statements (USA Only) 439Reference / Legal / RegulatoryDeclaration of Conformityaccording to ISO / IEC Guide 22 and EN 45014Manufacturer Nam

Strona 379

44 Array Controller Enclosure Components Figure 15Power Supply Fan Module

Strona 380 - Isolating Causes

440 FCC Statements (USA Only)

Strona 381

Glossary441GLOSSARYadapterA printed circuit assembly that transmits user data (I/Os) between the host system’s internal bus and the external Fibre Cha

Strona 382 - Table 52

442 bindThe process of configuring unassigned disks into a LUN disk group. Disks can be bound into one of the following LUN disk groups: RAID

Strona 383 - 7 REMOVAL AND REPLACEMENT

443GlossaryClass of ServiceThe types of services provided by the Fibre Channel topology and used by the communicating port.controllerA removabl

Strona 384

444 disk array controllerA printed-circuit board with memory modules that manages the overall operation of the disk array. The disk array cont

Strona 385 - Replacement

445GlossaryEPROMErasable Programmable Read-Only Memory.fabricA Fibre Channel term that describes a crosspoint switched network, which is one of

Strona 386 - Disk Enclosure Modules

446 25 MB/s (quarter speed), or 12.5 MB/s (eighth speed) over distances of up to 100 m over copper media, or up to 10 km over optical links. Th

Strona 387

447GlossaryframeThe smallest indivisible unit of application-data transfer used by Fibre Channel. Frame size depends on the hardware implementa

Strona 388 - Installing

448 hostA processor that runs an operating system using a disk array for data storage and retrieval.hot swappableHot swappable components can b

Strona 389

449Glossarycreated on the same disk array. A numeric value is assigned to a LUN at the time it is created. LVD-SCSI Low voltage differential im

Strona 390

Array Controller Enclosure Components 45Product DescriptionBattery Backup Unit The controller enclosure contains one removable battery backup un

Strona 391 - Figure 96

450 NVSRAMThe disk array controller stores operating configuration information in this non-volatile SRAM (referred to as NVSRAM). The contents

Strona 392 - Disk Enclosure Fan Module

451GlossaryPROM (Programmable Read-Only Memory)SP-resident boot code that loads the SP microcode from one of the disk array’s database drives w

Strona 393 - Installing the Fan Module

452 parity information, depending on the RAID level of the LUN. Until a rebuild is complete, the disk array is operating in degraded mode and i

Strona 394 - Hot Swappable Component!

453GlossarySIMM (Single In-line Memory Module)A memory module that provides the local storage (cache) for an SP. An SP must have at least two 4

Strona 395 -

454 drivers on the bus, and also impedance matching to prevent signal reflections at the ends of the cable. The SCSI bus requires termination a

Strona 396

Index455INDEXAA5628A, Array Manager 60 20AC power specifications 425disk enclosure 421acousticscontroller enclosure 423disk enclosure 427adapterFibre

Strona 397 - Removing the Front Cover

456 Indexcalculating LUN capacity 292changing LUN ownership 293changing rebuild priority settings 305checking disk array status 282checking reb

Strona 398 - Controller Fan Module

Index 457Indexmaximum 75changing LUN ownership 293channel numberdisk module 244channel:IDdescribed 280checking disk array statususing Array Mana

Strona 399

458 Indexpower-down sequence 205power-up sequence 198rebuild process 61upgrade and add-on products 416using as a boot device 222ventilation 403

Strona 400 - Removing the BBU

Index 459Indexprimary LUN path 64drive lockout 387driverssystem 146Eelectrical requirements 147EMC compliance 434EMS hardware event monitoring 2

Strona 401 - Figure 101

46 Array Controller Enclosure ComponentsThe BBU contains four LEDs that identify the condition of the battery. Internally, the BBU consists of

Strona 402 - Installing the BBU

460 Indextips for selecting disks 62global hot spare disksdescribed 61Hhardware event monitoring See EMS hardware event monitoringhardware path

Strona 403

Index 461Indexlog filesmanaging 307logsmanaging 309loop ID See Fibre Channel host IDlosing LUN 0 376LUNaddressing 208assigning ownership 247bind

Strona 404

462 Indexrecommended for HP System/E racks 151troubleshooting 380performancearray configuration 73I/Os per second 74impact of configuration set

Strona 405

Index 463Indexdescribed 55five disk enclosure array 94four disk enclosure array 90six disk enclosure array 98storage capacity 75three disk enclo

Strona 406

464 Indexcache flush threshold 300cache page size 300configuration switches 176controller date and time 297stripe segment size 249SF21 384SF88

Strona 407 - SCSI Cables

Index 465IndexTthroughputFibre Channel 71SCSI channels 72topologiesunsupported Windows 131topologybasic 102, 103error recovery 108campus 102, 12

Strona 408

466 Index

Strona 409

Disk Array High Availability Features 47Product Description Disk Array High Availability Features High availability systems are designed to prov

Strona 410

48 Disk Array High Availability FeaturesThe disk array uses hardware mirroring, in which the disk array automatically synchronizes the two disk

Strona 411 - Fibre Channel Host Adapters

Disk Array High Availability Features 49Product Description Figure 17Calculating Data ParityData StripingData striping, which is used on RAID 0,

Strona 412 - Models and Options

5About This BookThis guide is intended for use by system administrators and others involved in operating and managing the HP SureStore E Disk Array

Strona 413 - Table 54

50 Disk Array High Availability Featuresusing a 5-disk RAID 5 LUN, a stripe segment size of 32 blocks (16 KB) would ensure that an entire I/O w

Strona 414

Disk Array High Availability Features 51Product Descriptionfails. RAID-0 provides enhanced performance through simultaneous I/Os to multiple dis

Strona 415

52 Disk Array High Availability Featuresindividual disks. For highest data availability, each disk in the mirrored pair must be located in a di

Strona 416 - Table 58

Disk Array High Availability Features 53Product Descriptionpair. For highest data availability, each disk in the mirrored pair must be located i

Strona 417 - PDU/PDRU Products

54 Disk Array High Availability Featuresmore disks. For highest availability, the disks in a RAID 3 LUN must be in different enclosures.If a di

Strona 418 - Replaceable Parts

Disk Array High Availability Features 55Product DescriptionRAID 3 works well for single-task applications using large block I/Os. It is not a go

Strona 419 - Table 61

56 Disk Array High Availability Features Figure 22RAID 5 LUNWith its individual access characteristics, RAID 5 provides high read throughput fo

Strona 420 - Weight:

Disk Array High Availability Features 57Product DescriptionRAID Level Comparisons To help you decide which RAID level to select for a LUN, the f

Strona 421 - Heat Output:

58 Disk Array High Availability Features * Compares the relative read and write performance for array configurations with the performance of

Strona 422 - Environmental Specifications

Disk Array High Availability Features 59Product Description Table 4 RAID Level Comparison: General Performance CharacteristicsRAID Level Gener

Strona 423 - Acoustics

6Related Documents and InformationThe following items contain information related to the installation and use of the HP SureStore E Disk Array and its

Strona 424 - Weight:

60 Disk Array High Availability Features Table 5 RAID Level Comparison: Application and I/O Pattern Performance CharacteristicsRAID level Appl

Strona 425 - DC Power Output:

Disk Array High Availability Features 61Product DescriptionGlobal Hot Spare DisksA global hot spare disk is reserved for use as a replacement di

Strona 426

62 Disk Array High Availability FeaturesSettings that give a higher priority to the rebuild process will cause the rebuild to complete sooner,

Strona 427

Disk Array High Availability Features 63Product Description Figure 23Rebuild Process on a RAID 5 LUN (or Volume Group)The information on the hot

Strona 428

64 Disk Array High Availability FeaturesPrimary and Alternate I/O PathsThere are two I/O paths to each LUN on the disk array - one through cont

Strona 429 - Limitation of Warranty

Capacity Management Features 65Product DescriptionCapacity Management Features The disk array uses a number of features to manage its disk capac

Strona 430

66 Capacity Management Features•Hot spare group – All disks assigned the role of global hot spare become members of this group. Up to six disks

Strona 431 - Regulatory

Capacity Management Features 67Product Descriptioncontroller with 256 Mbytes of cache will use half of the memory to mirror the other controller

Strona 432

68 Capacity Management Features

Strona 433

Topology and Array Planning692 TOPOLOGY AND ARRAY PLANNINGOverview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 434 - Regulatory Compliance

7Contents1 Product DescriptionProduct Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 435 - FCC Statements (USA Only)

70 OverviewOverviewThis chapter provides information to assist you in configuring the Disk Array FC60 to meet your specific storage needs. Fact

Strona 436 - Harmonics Conformance (Japan)

Array Design Considerations 71Topology and Array PlanningArray Design ConsiderationsThe Disk Array FC60 provides the versatility to meet varying

Strona 437

72 Array Design Considerationsenclosures can be added incrementally (up to six) as storage requirements grow. Multiple SCSI channels also incre

Strona 438

Array Design Considerations 73Topology and Array Planningthe array for high availability, there must be no single points of failure. This means

Strona 439 - Declaration of Conformity

74 Array Design Considerationsof the buses must be configured with at least four disk modules (eight disk modules per disk enclosure). This con

Strona 440

Array Design Considerations 75Topology and Array PlanningStorage CapacityFor configurations where maximum storage capacity at minimum cost is a

Strona 441 - GLOSSARY

76 Array Design Considerationsanother, two or one disk enclosures, respectively, can be added by using split-bus mode. However, if you are addi

Strona 442 - 442

Recommended Disk Array Configurations 77Topology and Array PlanningRecommended Disk Array Configurations This section presents recommended confi

Strona 443 - Glossary

78 Recommended Disk Array Configurations•Global hot spares - although none of the configurations use global hot spares, their use is recommende

Strona 444 - 444

Recommended Disk Array Configurations 79Topology and Array Planning•Data Availability– Not recommended for maximum high availability. – Handles

Strona 445 - 445

8 Disk Groups. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65Disk Array Cachin

Strona 446 - 446

80 Recommended Disk Array ConfigurationsTwo Disk Enclosure ConfigurationsHigh Availability/ High Performance •Hardware Configuration– Two disk

Strona 447 - 447

Recommended Disk Array Configurations 81Topology and Array PlanningFigure 25Two Disk Enclosure High Availability/ High Performance Configuration

Strona 448 - 448

82 Recommended Disk Array ConfigurationsMaximum Capacity NoteThis configuration is not recommended for environments where high availability is

Strona 449 - 449

Recommended Disk Array Configurations 83Topology and Array PlanningFigure 26Two Disk Enclosure Maximum Capacity Configuration

Strona 450 - 450

84 Recommended Disk Array ConfigurationsThree Disk Enclosure ConfigurationsHigh Availability/ High Performance •Hardware Configuration– Two dis

Strona 451 - 451

Recommended Disk Array Configurations 85Topology and Array PlanningFigure 27Three Disk Enclosure High Availability/ High Performance Configurati

Strona 452 - 452

86 Recommended Disk Array ConfigurationsMaximum Capacity•Hardware Configuration– Two disk array controllers connected directly to host Fibre Ch

Strona 453 - 453

Recommended Disk Array Configurations 87Topology and Array PlanningFigure 28Three Disk Enclosure Maximum Capacity Configuration

Strona 454 - 454

88 Recommended Disk Array ConfigurationsFour Disk Enclosure ConfigurationsHigh Availability/High Performance •Hardware Configuration– Two disk

Strona 455

Recommended Disk Array Configurations 89Topology and Array PlanningFigure 29Four Disk Enclosure High Availability/High Performance Configuration

Strona 456 - See battery backup module

9ContentsNon-High Availability Topologies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .133High Availability Topolog

Strona 457 - See cstm

90 Recommended Disk Array ConfigurationsMaximum Capacity•Hardware Configuration– Two disk array controllers connected directly to host Fibre Ch

Strona 458 - See disk enclosure

Recommended Disk Array Configurations 91Topology and Array PlanningFigure 30Four Disk Enclosure Maximum Capacity Configuration

Strona 459

92 Recommended Disk Array ConfigurationsFive Disk Enclosure ConfigurationsHigh Availability/High Performance •Hardware Configuration– Two disk

Strona 460 - See global hot spare

Recommended Disk Array Configurations 93Topology and Array PlanningFigure 31Five Disk Enclosure High Availability/High Performance Configuration

Strona 461 - See mstm

94 Recommended Disk Array ConfigurationsMaximum Capacity•Hardware Configuration– Two disk array controllers connected directly to host Fibre Ch

Strona 462

Recommended Disk Array Configurations 95Topology and Array PlanningFigure 32Five Disk Enclosure Maximum Capacity Configuration

Strona 463

96 Recommended Disk Array ConfigurationsSix Disk Enclosure ConfigurationsHigh Availability/High Performance •Hardware Configuration– Two disk a

Strona 464 - See disk

Recommended Disk Array Configurations 97Topology and Array PlanningFigure 33Six Disk Enclosure High Availability/High Performance Configuration

Strona 465 - See xstm

98 Recommended Disk Array ConfigurationsMaximum Capacity •Hardware Configuration– Two disk array controllers connected directly to host Fibre C

Strona 466 - 466 Index

Recommended Disk Array Configurations 99Topology and Array PlanningFigure 34Six Disk Enclosure High Maximum Capacity Configuration

Komentarze do niniejszej Instrukcji

Brak uwag