Hp Surestore Disk Array 12h and FC60 Instrukcja Użytkownika Strona 92

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 91
92 Recommended Disk Array Configurations
Five Disk Enclosure Configurations
High Availability/High Performance
Hardware Configuration
Two disk array controllers connected directly to host Fibre Channel adapters
Five disk enclosures with ten 73 GByte disks each (50 disks total)
Disk enclosures configured for full-bus mode (one SCSI channel per enclosure)
LUN Configuration
Ten RAID 0/1 LUNs, each comprising four disks (2+2)
Five RAID 1 LUNs, each comprising two disks (1+1)
Each disk in a LUN is in a separate enclosure.
High Availability
Handles a single disk failure, BCC failure, single channel failure, or a single
controller failure
Expansion requires powering down the disk array and adding an additional disk
enclosure and cabling
Disk Capacity
Maximum capacity 3650 GBytes
Usable capacity 1825 GBytes
Przeglądanie stron 91
1 2 ... 87 88 89 90 91 92 93 94 95 96 97 ... 465 466

Komentarze do niniejszej Instrukcji

Brak uwag