Hp Surestore Disk Array 12h and FC60 Instrukcja Użytkownika Strona 276

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 275
276 Managing the Disk Array Using Array Manager 60
Managing the Disk Array Using Array Manager 60
The Array Manager 60 command line utilities allow you to configure, control, and monitor
all aspects of disk array operation. Array Manager 60 is intended for performing the more
advanced tasks involved in managing the disk array.
The Array Manager 60 utilities and the tasks they are used to perform are summarized in
Table 33 and Table 34.
Note
You must log in as superuser or root to use the Array Manager 60 utilities to
manage the disk array.
Table 33
Array Manager 60 Task Summary
Task Command
Capacity Management
Binding a LUN amcfg -L <cntrlrID>:<LUN> -d <channel:ID>,<channel:ID>.....
-r <RAIDlevel> <options> <ArrayID>
Unbinding a LUN amcfg -D <LUN> [-force] <ArrayID>
Calculating LUN Capacity amcfg -C -d channel:ID,channel:ID...
-r <RAIDlevel> -s <stripe> <ArrayID>
Adding a Global Hot Spare ammgr -h channel:ID <ArrayID>
Removing a Global Hot Spare ammgr -d channel:ID <ArrayID>
Identifying Disks amdsp -d <ArrayID>
Changing LUN Ownership amcfg -M <LUN> -c <cntrlrID> <ArrayID>
Replacing a LUN amcfg -R <cntrlrID>:<LUN> -d <channel:ID>,<channel:ID>.....
-r <RAIDlevel> <options> <ArrayID>
Disk Array Status
Displaying Status Information amdsp <option> <ArrayID>
Listing Disk Array IDs amdsp -i
Rescanning for Disk Arrays amdsp -R
Przeglądanie stron 275
1 2 ... 271 272 273 274 275 276 277 278 279 280 281 ... 465 466

Komentarze do niniejszej Instrukcji

Brak uwag