4-21
Working with Disks
The following sections describe how to display and, if appropriate,
set the S.M.A.R.T. attributes.
Displaying S.M.A.R.T. Capable Devices
The S.M.A.R.T. capable device attribute indicates if a SCSI
device possesses the S.M.A.R.T. technology.
To display whether the devices connected to a controller are
S.M.A.R.T. capable devices, use the disk show smart command,
as in the following example. The Smart Capable Device column
contains a Y for both devices, indicating that the devices possess
S.M.A.R.T. technology.
HPN0> disk show smart
Executing: disk show smart
Smart Method of Enable
Capable Informational Exception Performance Error
C:ID:L Device Exceptions(MRIE) Control Enabled Count
------ ------- ---------------- --------- ----------- ------
2:01:0 Y 6 Y N 0
2:02:0 Y 6 Y N 0
Displaying and Setting the Method of Reporting Informational
Exceptions
The S.M.A.R.T. method of reporting informational
exceptions (MRIE) attribute identifies the method by which
exceptions are reported. The CLI allows you to do the following:
Display the MRIE of your devices
report count Display
Set
disk show
smart
disk set
smart
Displaying and
Setting the Report
Count
error count Display
Set
disk show
smart
disk set
smart
Displaying and
Clearing the Error
Count
S.M.A.R.T. Attribute
CLI
Operations
Related