HP ProLiant BL620c G7 Server Blade
User Guide
Abstract
This document is for the person who installs, administers, and troubleshoots servers and storage systems. HP assumes you are qualified in the
servicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels.
Part Number: 613849-003
April 2011
Edition: 3
Przeglądanie stron 0
1 2 3 4 5 6 ... 122 123

Podsumowanie treści

Strona 1 - User Guide

HP ProLiant BL620c G7 Server Blade User Guide Abstract This document is for the person who installs, administers, and troubleshoots servers and sto

Strona 2

Component identification 10 Item Description 15 Processor 1 16 System battery 17 SAS/SATA backplane power connector 18 Processor 2 The symbols

Strona 3 - Contents

Regulatory compliance notices 100 radio communications. However, there is no guarantee that interference will not occur in a particular installation

Strona 4 - Contents 4

Regulatory compliance notices 101 This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.

Strona 5 - Contents 5

Regulatory compliance notices 102 This symbol on the product or on its packaging indicates that this product must not be disposed of with your othe

Strona 6 - Contents 6

Regulatory compliance notices 103 Class B equipment Chinese notice Class A equipment Laser compliance This product may be provided with an optic

Strona 7 - Component identification

Regulatory compliance notices 104 For more information about battery replacement or proper disposal, contact an authorized reseller or an authorized

Strona 8 - SAS and SATA hard drive LEDs

Regulatory compliance notices 105 Japanese notices Taiwan notices

Strona 9 - System board components

Electrostatic discharge 106 Electrostatic discharge Preventing electrostatic discharge To prevent damaging the system, be aware of the precautions y

Strona 10 - System maintenance switch

Specifications 107 Specifications Environmental specifications Specification Value Temperature range* — Operating 10°C to 35°C (50°F to 95°F) Non

Strona 11 - Accessing the redundant ROM

Technical support 108 Technical support Before you contact HP Be sure to have the following information available before you call HP: • Technical s

Strona 12 - HP c-Class Blade SUV Cable

Technical support 109 • Optional—Parts for which customer self repair is optional. These parts are also designed for customer self repair. If, howe

Strona 13 - Item Connector Description

Component identification 11 5. Install the access panel (on page 16). 6. Install the server blade in the enclosure and power up the server blade. 7

Strona 14 - Operations

Technical support 110 Riparazione da parte del cliente Per abbreviare i tempi di riparazione e garantire una maggiore flessibilità nella sostituzion

Strona 15 - Remove the server blade

Technical support 111 CSR-Teile werden abhängig von der Verfügbarkeit und vom Lieferziel am folgenden Geschäftstag geliefert. Für bestimmte Standort

Strona 16 - Install the access panel

Technical support 112 Para obtener más información acerca del programa de Reparaciones del propio cliente de HP, póngase en contacto con su proveedo

Strona 17 - Remove the left DIMM baffle

Technical support 113 Opcional – Peças cujo reparo feito pelo cliente é opcional. Essas peças também são projetadas para o reparo feito pelo cliente

Strona 20

Acronyms and abbreviations 116 Acronyms and abbreviations ACU Array Configuration Utility AES-NI advanced encryption standard new instructions AMP

Strona 21 - Overview

Acronyms and abbreviations 117 IML Integrated Management Log KVM keyboard, video, and mouse LV DIMM Low voltage DIMM NUMA Non-Uniform Memory Arch

Strona 22 - Remove the device bay blank

Acronyms and abbreviations 118 SDDC Single Device Data Correction SDHC Secure Digital High-Capacity SIM Systems Insight Manager SMB scalable memo

Strona 23 - Setup 23

Index 119 A access panel 16 accessing a server blade with local KVM 58, 59 ACU (Array Configuration Utility) 71 additional informatio

Strona 24

Component identification 12 DIMM slot locations DIMM slots are numbered sequentially (1 through 16) for each processor. The supported AMP modes use

Strona 25

Index 120 DIMMs, dual-rank 37 DIMMs, installation 46 DIMMs, quad-rank 37 disposal, battery 101, 103 disposal, waste 101 Dou

Strona 26 - Setup 26

Index 121 internal health LED 8 internal SD support 75 internal USB connector 10 internal USB functionality 74, 75 J Japanese no

Strona 27 - Connecting to the network

Index 122 removing the access panel 16 removing the server blade 15 required information 108 resources 66, 80 resources, trouble

Strona 28 - Installing a server blade

Index 123 website, HP 108 wireless devices 104, 105

Strona 29 - Completing the configuration

Component identification 13 Item Connector Description 1 Server blade For connecting to the SUV connector on the server blade front panel 2 Vi

Strona 30 - Processor option

Operations 14 Operations Power up the server blade The Onboard Administrator initiates an automatic power-up sequence when the server blade is insta

Strona 31

Operations 15 a. Select the Enclosure Information tab, and then select the Overall checkbox in the Device Bays item. b. Initiate a shutdown from th

Strona 32

Operations 16 Remove the access panel To remove the component: 1. Power down the server blade (on page 14). 2. Remove the server blade (on page 15

Strona 33

Operations 17 3. Remove the hard drive. To replace the component, reverse the removal procedure. Remove the left DIMM baffle To remove the compone

Strona 34

Operations 18 7. Remove the left DIMM baffle. Remove the right DIMM baffle To remove the component: 1. Power down the server blade (on page 14).

Strona 35

Operations 19 Remove the front panel/hard drive cage assembly To remove the component: 1. Power down the server blade (on page 14). 2. Remove the

Strona 36 - Memory option

© Copyright 2010, 2011 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only war

Strona 37 - DIMM identification

Operations 20 2. Remove the server blade (on page 15). 3. Remove the access panel (on page 16). 4. Do one of the following: o Remove the battery

Strona 38 - DIMM installation guidelines

Setup 21 Setup Overview Installation of a server blade requires the following steps: 1. Install and configure an HP BladeSystem c-Class enclosure.

Strona 39

Setup 22 1. Remove the device bay blank. 2. Remove the three adjacent blanks. Removing a c7000 device bay divider 1. Slide the device bay shelf

Strona 40 - Channel Slot Slot number

Setup 23 2. Push the device bay shelf back until it stops, lift the right side slightly to disengage the two tabs from the divider wall, and then ro

Strona 41 - Hemisphere mode

Setup 24 Removing a c3000 device bay mini-divider or device bay divider 1. Slide the locking tab down. 2. Remove the mini-divider or divider: o

Strona 42

Setup 25 d. Remove the divider from the enclosure. Creating a full-height device bay blank 1. Obtain the coupler plate: o If you are using a dev

Strona 43 - Memory RAS

Setup 26 3. Fit the slots on the bottom of the second blank on to the tabs on the coupler plate, and then slide the second blank forward until it sn

Strona 44

Setup 27 • HP BladeSystem c3000 Enclosure To support network connections for specific signals, install an interconnect module in the bay correspon

Strona 45 - HP Memory Quarantine

Setup 28 Two types of interconnect modules are available for HP BladeSystem c-Class enclosures: Pass-Thru modules and switch modules. For more infor

Strona 46 - Installing DIMMs

Setup 29 2. Prepare the server blade for installation. 3. Install the server blade. Completing the configuration To complete the server blade an

Strona 47

Contents 3 Contents Component identification ...

Strona 48 - Prepare the hard drive

Hardware options installation 30 Hardware options installation Introduction If more than one option is being installed, read the installation instru

Strona 49 - Mezzanine card option

Hardware options installation 31 CAUTION: The heatsink thermal interface media is not reusable and must be replaced if the heatsink is removed fro

Strona 50

Hardware options installation 32 8. Open the processor locking lever and the processor socket retaining bracket. Do not remove the processor socket

Strona 51 - Controller options

Hardware options installation 33 10. Align the processor installation tool with the socket, and then install the processor. THE PINS ON THE SYSTEM B

Strona 52

Hardware options installation 34 11. Press the tabs on the processor installation tool to separate it from the processor, and then remove the tool.

Strona 53 - Installing a capacitor pack

Hardware options installation 35 13. Remove the heatsink protective cover. CAUTION: Orient the heatsink as indicated in the procedure. Otherw

Strona 54

Hardware options installation 36 Memory option Several DDR3 RDIMM option kits are available to expand server blade memory. The server blade supports

Strona 55

Hardware options installation 37 supports the Intel Xeon E7 family processors. LV DIMMs are not supported on the HP ProLiant BL620c G7 Server Blade

Strona 56

Hardware options installation 38 Item Description Definition 6 DIMM type R = RDIMM (registered) E = UDIMM (unbuffered with ECC) For the latest s

Strona 57 - Additional TPM features

Hardware options installation 39 • AMP modes Advanced ECC, DDDC, HP Memory Quarantine, Online Spare, and Mirrored Memory have further requirements

Strona 58 - Cabling

Contents 4 HP Memory Quarantine ...

Strona 59

Hardware options installation 40 Channel Slot Slot number H 9 7 B F 16 15 8 D H 14 13 Memory architecture for processor 2 Channel Slot Slot

Strona 60 - Item Description

Hardware options installation 41 Hemisphere mode The Intel® Xeon® E7 family and 6500/7500 series processor architectures incorporate Hemisphere mo

Strona 61 - Network-based PXE deployment

Hardware options installation 42 The following illustration shows examples of Hemisphere mode and non-Hemisphere mode populations. The two non-Hemi

Strona 62 - Deployment infrastructure

Hardware options installation 43 • The best performance is obtained when all installed processors are enabled for Hemisphere mode. Hemisphere mode

Strona 63 - Deployment methods

Hardware options installation 44 • Online Spare memory mode provides protection against persistent DRAM failure. Rank-sparing is more efficient tha

Strona 64 - CD-ROM deployment

Hardware options installation 45 HP Memory Quarantine The server blade is HP Memory Quarantine ready. The server blade will support this feature wit

Strona 65 - Diskette image deployment

Hardware options installation 46 Mirrored Memory population guidelines Errors that are not corrected by ECC, SDDC, or DDDC cannot be corrected by On

Strona 66 - SAN configuration

Hardware options installation 47 6. Install the DIMM. 7. Do one of the following: o Install the right DIMM baffle. o Install the left DIMM baffl

Strona 67 - Configuration tools

Hardware options installation 48 1. Remove the hard drive blank. 2. Prepare the hard drive.

Strona 68 - HP ROM-Based Setup Utility

Hardware options installation 49 3. Install the hard drive. 4. Determine the status of the hard drive from the hot-plug hard drive LEDs ("SAS

Strona 69 - Configuring AMP modes

Contents 5 Change control and proactive notification ... 79 C

Strona 70 - Configuring mirrored memory

Hardware options installation 50 4. Remove the mezzanine connector cover. 5. Align the mezzanine connector on the optional mezzanine card with the

Strona 71 - Array Configuration Utility

Hardware options installation 51 Controller options The server blade ships with an embedded Smart Array P410i Controller. RAID 0 and 1 are supported

Strona 72 - Management tools

Hardware options installation 52 CAUTION: To prevent a server blade malfunction or damage to the equipment, do not add or remove the battery pack

Strona 73 - Erase Utility

Hardware options installation 53 6. Install the cache module. 7. Install the capacitor pack ("Installing a cache module" on page 51). 8.

Strona 74 - Redundant ROM support

Hardware options installation 54 6. Install the capacitor pack. 7. Install the server blade ("Installing a server blade" on page 28). 8.

Strona 75 - Diagnostic tools

Hardware options installation 55 • Any attempt to remove an installed TPM from the system board breaks or disfigures the TPM security rivet. Upon l

Strona 76

Hardware options installation 56 6. Install the TPM security rivet by pressing the rivet firmly into the system board. 7. Install the access panel

Strona 77 - Keeping the system current

Hardware options installation 57 CAUTION: When a TPM is installed and enabled on the server blade, data access is locked if you fail to follow t

Strona 78 - HP Smart Update Manager

Cabling 58 Cabling Using the HP c-Class Blade SUV Cable The HP c-Class Blade SUV Cable enables the user to perform server blade administration, conf

Strona 79 - Care Pack

Cabling 59 4. Connect a USB keyboard to the second USB connector. Item Description 1 Monitor 2 USB mouse 3 HP c-Class Blade SUV Cable 4 Video

Strona 80 - Troubleshooting

Contents 6 Technical support ...

Strona 81 - Symbols on equipment

Cabling 60 Item Description 1 Monitor 2 USB mouse 3 HP c-Class Blade SUV Cable 4 Server blade 5 USB hub 6 USB keyboard 7 USB CD/DVD-ROM dr

Strona 82 - Symptom information

Software and configuration utilities 61 Software and configuration utilities Server blade deployment tools HP BladeSystem c-Class Advanced managemen

Strona 83 - Troubleshooting 83

Software and configuration utilities 62 Deployment overview When a PXE-enabled target server blade boots, it obtains an IP address from a DHCP serve

Strona 84 - Troubleshooting flowcharts

Software and configuration utilities 63 o 64 MB of RAM o 64 MB of free hard drive space o 10-Mb/s network adapter • PXE deployment server (storin

Strona 85 - Start diagnosis flowchart

Software and configuration utilities 64 PXE deployment PXE enables server blades to load an image over the network from a PXE server, and then execu

Strona 86 - General diagnosis flowchart

Software and configuration utilities 65 • USB CD-ROM (on page 65) iLO virtual CD-ROM To deploy with a boot CD: 1. Do one of the following: o Ins

Strona 87

Software and configuration utilities 66 Before beginning the deployment process, connect the server blade to the network. NOTE: For more informa

Strona 88 - Symptoms:

Software and configuration utilities 67 • The server blade enclosure management module firmware is up-to-date. Refer to the HP Business Support Cen

Strona 89

Software and configuration utilities 68 HP ROM-Based Setup Utility RBSU is a configuration utility embedded in ProLiant servers that performs a wide

Strona 90 - POST problems flowchart

Software and configuration utilities 69 Drives installed Drives used RAID level 1 1 RAID 0 2 2 RAID 1 3, 4, 5, or 6 3, 4, 5, or 6 RAID 5 M

Strona 91

Component identification 7 Component identification Front panel components and LEDs Item Description 1 UID LED 2 Health LED 3 Flex 1 LED 4 Fle

Strona 92 - OS boot problems flowchart

Software and configuration utilities 70 • RAID Memory Mode—Provides protection levels similar to Mirrored Memory Mode, and it requires less memory

Strona 93 - • Corrupted OS

Software and configuration utilities 71 Configuring lockstep memory To configure Lockstep memory: 1. Install the required DIMMs ("Installing

Strona 94

Software and configuration utilities 72 • Deleting a logical drive configuration • Setting the controller to be the boot controller If you do not

Strona 95 - • Redundancy failure

Software and configuration utilities 73 ROMPaq utility The ROMPaq utility enables you to upgrade the system firmware (BIOS). To upgrade the firmware

Strona 96 - (http://www.hp.com/support)

Software and configuration utilities 74 Run the Erase Utility if you must erase the system for the following reasons: • You want to install a new o

Strona 97 - Troubleshooting 97

Software and configuration utilities 75 External USB functionality HP provides external USB support to enable local connection of USB devices for se

Strona 98 - Battery replacement

Software and configuration utilities 76 You can view recorded events in the IML in several ways, including the following: • From within HP SIM •

Strona 99 - Class B equipment

Software and configuration utilities 77 Keeping the system current Drivers IMPORTANT: Always perform a backup before installing or updating devi

Strona 100 - Modifications

Software and configuration utilities 78 Operating System Version Support For information about specific versions of a supported operating system, re

Strona 101 - • EMC Directive 2004/108/EC

Software and configuration utilities 79 Change control and proactive notification HP offers Change Control and Proactive Notification to notify cust

Strona 102 - Korean notice

Component identification 8 SAS and SATA hard drive LEDs Item Description 1 Fault/UID LED (amber/blue) 2 Online LED (green) SAS and SATA ha

Strona 103 - Laser compliance

Troubleshooting 80 Troubleshooting Troubleshooting resources The HP ProLiant Servers Troubleshooting Guide provides procedures for resolving common

Strona 104 - Wireless devices

Troubleshooting 81 Important safety information Before servicing this product, read the Important Safety Information document provided with the s

Strona 105 - Taiwan notices

Troubleshooting 82 WARNING: To reduce the risk of personal injury or damage to the equipment, be sure that: • The leveling feet are extended to t

Strona 106 - Electrostatic discharge

Troubleshooting 83 o HP recommends you have access to the server documentation for server-specific information. o HP recommends you have access to

Strona 107 - Specifications

Troubleshooting 84 Always use the recommended minimum configuration above before removing any processors. If you are unable to isolate the issue wit

Strona 108 - Technical support

Troubleshooting 85 do not provide a troubleshooting solution, follow the diagnostic steps in "General diagnosis flowchart (on page 86)." T

Strona 109 - Technical support 109

Troubleshooting 86 General diagnosis flowchart The General diagnosis flowchart provides a generic approach to troubleshooting. If you are unsure

Strona 110 - Customer Self Repair

Troubleshooting 87 Item See 4 The most recent version of a particular server blade or option firmware is available on the HP Support website (http:

Strona 111 - Technical support 111

Troubleshooting 88 Server blade power-on problems flowchart Symptoms: • The server does not power on. • The system power LED is off or amber.

Strona 112 - Reparo feito pelo cliente

Troubleshooting 89 • The health LED is red or amber. NOTE: For the location of server LEDs and information on their statuses, refer to the serv

Strona 113 - Technical support 113

Component identification 9 Online/activity LED (green) Fault/UID LED (amber/blue) Interpretation Off Steadily amber A critical fault condition has

Strona 114 - Technical support 114

Troubleshooting 90 POST problems flowchart Symptoms: • Server does not complete POST NOTE: The server has completed POST when the system att

Strona 115 - Technical support 115

Troubleshooting 91 Item See 1 Server blade power-on problems flowchart (on page 88) 2 "POST error messages and beep codes (on page 96)&quo

Strona 116 - Acronyms and abbreviations

Troubleshooting 92 OS boot problems flowchart There are two ways to use SmartStart when diagnosing OS boot problems on a server blade: • Use iL

Strona 117

Troubleshooting 93 Possible causes: • Corrupted OS • Hard drive subsystem problem • Incorrect boot order setting in RBSU Item See 1 HP ROM-B

Strona 118

Troubleshooting 94 * See the server blade OS boot problems flowchart (on page 92) Server fault indications flowchart Symptoms: • Server boots, bu

Strona 119 - Index 119

Troubleshooting 95 NOTE: For the location of server LEDs and information on their statuses, refer to the server documentation. Possible causes:

Strona 120 - Index 120

Troubleshooting 96 POST error messages and beep codes For a complete listing of error messages, refer to the "POST error messages" in th

Strona 121 - Index 121

Troubleshooting 97 WARNING: To avoid potential problems, ALWAYS read the warnings and cautionary information in the server documentation before re

Strona 122 - Index 122

Battery replacement 98 Battery replacement If the server blade no longer automatically displays the correct date and time, you may need to replace t

Strona 123 - Index 123

Regulatory compliance notices 99 Regulatory compliance notices Regulatory compliance identification numbers For the purpose of regulatory compliance

Komentarze do niniejszej Instrukcji

Brak uwag