  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 7
8
7. Push the power supply into the SPU firmly until the
insertion/extractor lever can hook under the extended tab on the SPU.
8. Push the insertion/extractor lever down, flush with the power supply.
This firmly seats the power supply to the system board.
9. Tighten the two captive mounting screws.
10.Be sure the power cord associated with the power supply installed is
connected at the back of the SPU.
11.Put the power switch, on the front of the power supply, in to the ON
position.
NOTE The power OK LED should be on when the power switch is
in the ON position, and there is a power cord plugged
in.
12.Replace the EMI shield by inserting the tabs on the top of the EMI
shield into the slots chassis just below the front panel. Then push the
EMI shield into the chassis and tighten the two mounting screws on
the bottom.
13.Replace the front bezel by aligning it over the front panel and front of
the chassis and snapping it to the bezel retainer clips along the sides