Set LED State
Turns on or off the amber LED located on the 4PSE. The current state is indicated by the LED State
attribute.
Alarm Panel (Telco)
For Telco systems only, this object can be displayed and monitored in OSM by using the Start
Monitoring Alarm Panel action, located under the Monitored Service LAN Devices object. You can
access its browser-based configuration interface through the Link to Web Interface action.
Location in OSM Tree: System > Monitored Service LAN Devices > Alarm Panel
Attributes
Alarm Panel
Displayed in the Attributes tab and Attributes dialog box only if the value is something
other than OK. Values
Service State
Physical
The state of the component as known to the operating system on the server.Device Status
The version of the firmware running on the alarm panel.Firmware Revision
The hardware version of the alarm panel.Hardware Revision
The IPv4 address of the alarm panel.IPv4 Address
Indicates whether the alarm panel has lost communication with the manager
that controls its LEDs. The possible values of this attribute are OK, Fault, and
Unknown.
LED Manager Communication State
The media access control (MAC) address of the alarm panel.MAC Address
Indicates whether the alarm panel microprocessor is in a good state (passed
POST). The possible values of this attribute are OK, Fault, and Unknown.
Microprocessor State
The part number of the component that was assigned in manufacturing. Use
part numbers for identifying and ordering parts.
Part Number
The state of the power in input A of the alarm panel. The possible values of
this attribute are OK, Fault, and Unknown.
Power Input A State
The state of the power in input B of the alarm panel. The possible values of
this attribute are OK, Fault, and Unknown.
Power Input B State
A unique identification number assigned to each alarm panel in
manufacturing.
Serial Number
Physical Location
The values displayed by these attributes are assigned through the Physical Configuration Tool.
A user-defined name assigned to identify the rack in which the alarm panel
is located.
Rack Name
A number (from 1 to 42) assigned to describe the location of the alarm panel
within the rack.
Rack Offset