Przeglądanie stron 140
5157/5157 ACL S-Series DLT Subsystems Installation/Users Guide
Installing and Configuring the 5157/5157 ACL Digital Linear Tape Subsystem
for S-Series Servers
7-16
Example 2: Changing the Values of Tape Drive Attributes
Use the SCF ALTER TAPE command to change the attribute
values for a tape drive attached to the system. The ALTER
command changes only the attributes specified in the command.
The following example of the ALTER command changes the
value of the compression attribute for the tape drive (5157,
5157 ACL) $TAPE0 to OFF and then issues the SCF INFO
command to make sure that the change has taken place:
->ALTER TAPE $TAPE0, COMPRESSION OFF
->INFO TAPE $TAPE0
STORAGE - Info TAPE configuration $TAPE0
STORAGE - Info TAPE configuration $TAPE0
SubType *Density *NumOpeners *RecSize *Compression *Adapter
Location
9 6250 6 8192 OFF 1, 1, 50